Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station cc alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />FEF <br />DUPLEX CONVENIENCE OUTLET <br />PqF <br />DUPLEX OUTLET ABOVE COUNTER <br />I <br />FEFwp <br />WEATHERPROOF DUPLEX OUTLET <br />1GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�',4 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />-� <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;Ol <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />5 <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />FTq <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />i� <br />THERMOSTAT <br />�]M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />t <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />POWER CO. <br />INTERSY: <br />BON <br />TERMINATION <br />NEC 14, 250.94—/ <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />opper to lights & outlets <br />opper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />i Alu <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />VERIFY METER LOCATION <br />WITH BUILDER <br />MAIN ELECTRICAL PLAN <br />SCALE:1/4"=1'-0" <br />O <br />M � <br />0 0 <br />z <br />z o <br />J M <br />� N <br />M <br />N z <br />o <br />Q) ( <br />Vi Y <br />W 0 <br />a <br />V <br />y <br />0 LU <br />N c E <br />Jim <br />U m <br />� W <br />® lIJ C <br />V =O y <br />� rn <br />J. <br />m <br />0 <br />14 <br />N N <br />N <br />LM O) <br />ZWg dz wz <br />w = O w <br />U) <br />y cz <br />WW> <br />Z 0, =Q o <br />'0 3 <br />y a mm <br />Z <br />ILL Q N h Q <br />W N "r <br />U OF <br />rn <br />0 <br />N <br />M <br />1 <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />ti <br />C.0 <br />w <br />Mz2 <br />0SS <br />Z <br />Q <br />� <br />ce E <br />F° <br />o <br />�� <br />» <br />Z" <br />�_ <br />Z <br />0 <br />oQ_ <br />0° <br />O E <br />N¢o <br />az <br />O <br />aZ <br />¢Z <br />>_' <br />to <br />U3 <br />¢ Z <br />0y <br />U <br />m 0 <br />a <br />O� <br />Z <br />co <br />W <br />0 g <br />ZZ <br />O <br />W <br />00 <br />Q Y <br />Uj <br />a o <br />r9 <br />�Y <br />o r <br />zI¢ <br />o — <br />U <br />c O <br />0 <br />L <br />> <br />O <br />CI <br />0 <br />0 <br />Q <br />0 co <br />C-- <br />° v <br />/11 m c <br />~ <br />V W <br />o <br />r <br />11 o <br />r <br />.rir• 0 pop <br />rn <br />ai <br />t M CV <br />0 <br />o <br />ccaa <br />Z <br />E <br />ca <br />0- <br />E <br />U Q p <br />JOB <br />NO: 19-5897 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.0 <br />