V-0" <br />ATTIC VENTILATION CALCULATIONS <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN, of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />See Elev <br />( ) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />19.000000 <br />2.000000 <br />Floor <br />2276 <br />2185 <br />312 <br />1092 <br />78 <br />546 <br />561.0 <br />285.0 <br />276.0 <br />(Zone 1) <br />"NOTE" <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN <br />SCALE: %4"=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806, <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ, FT. <br />Q <br />l— <br />Z N O <br />z " <br />Q M <br />d N <br />N <br />z <br />� a <br />� <br />0 <br />+ <br />fQ W g- <br />o Q <br />.O <br />�N <br />� e <br />= 2 <br />wa <br />� <br />� o <br />m <br />win <br />U <br />w <br />2 E <br />r...• <br />I <br />I <br />U o I <br />®0 <br />< � ml <br />� <br />m <br />Z <br />N N <br />b <br />a Mmzo <br />1 <br />w <br />6..U 111111 la <br />W K . 1 <br />W V L <br />� <br />z '.Cn N <br />^y�� 0 <br />a qo� <br />w <br />' <br />.e7 <br />g C,`}• tt �c,;>, <br />kin <br />`^ co <br />°L <br />q <br />' s4R3:e <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2017 <br />Florida Building Code <br />- <br />Residential 6th Edition. Engineer's signature and seal <br />is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />O <br />co <br />0 <br />w <br />CO <br />z <br />Z <br />U <br />Q Eg <br />o <br />� <br />» <br /><� <br />o <br />w <br />z® <br />Da <br />CL <br />5, <br />a ¢ <br />o <br />O <br />N ruQp <br />o <br />Q <br />�w <br />L <br />(a <br />o <br />- v <br />Z <br />0y <br />U <br />Nm <br />m O <br />Z <br />'<W <br />J <br />¢ y <br />z <br />U) <br />cn �? <br />o <br />a o <br />3 <br />W 3 <br />oz <br />F ~ <br />CD <br />CDw� <br />6i <br />� F <br />>° <br />CDa <br />C O <br />O <br />y <br />} <br />L <br />' <br />> <br />O <br />■� <br />L <br />1 <br />O <br />�1 <br />W <br />O <br />co <br />° <br />v <br />o) <br />r <br />2 O <br />o <br />L0 <br />r <br />00 <br />ai <br />m <br />T <br />0 <br />M CV <br />iri rl� <br />o <br />Z <br />Z <br />c <br />E Q <br />E <br />to <br />ns <br />c <br />it <br />L <br />o <br />U <br />a m <br />Q p <br />aci <br />_J <br />JOB <br />NO: <br />19-5897 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />5.0 <br />