My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39988 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39988 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 8:18:15 AM
Creation date
2/19/2025 4:16:30 PM
Metadata
Fields
Template:
Building Plans
Street #
39988
Location
Dawson Chase Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
21850
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T.O.P. <br />HDR HGT. L <br />2nd FIN. <br />milt FLR. <br />T.O.M. <br />HDR HGT. <br />9 <br />F.FL. <br />12 <br />5� <br />12 <br />12 <br />�5 <br />FRONT ELEVATION <br />1" x 4" SMOOTH <br />TEXTURED <br />TRIM / BAND <br />1" x 12" SMOOTH <br />TEXTURED <br />TRIM / BAND <br />- B1 <br />SCALE: 1 /4"=1'-0" <br />LEFT ELEVATION - B1, <br />------- T.O.P. <br />__-_--- HDR HGT. <br />CV <br />DC <br />2nd FIN. <br />------- FLR. C4)11* <br />T.O.M. -� <br />HDR HGT. <br />F.FL. <br />19 <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />.G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />*"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barters shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />l� <br />0 <br />z_ <br />z lie <br />z g <br />Q <br />a <br />� <br />NLU <br />z <br />y <br />N <br />to <br />LL, <br />c E <br />� <br />� <br />as <br />lolls <br />t4 N <br />g ° <br />LU <br />Q W► Et°rP/l <br />z m f <br />NCY <br />LLrn <br />< <br />.ri <br />t � <br />A <br />RnFESC' <br />o the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code <br />Residential 6th Edition. Engineer's signature and seal <br />- <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />M <br />N <br />�KK <br />E E <br />=0 <br />a <br />�O <br />=a <br />Q <br />$� <br />zC <br />`E° <br />z <br />U) <br />ZLL <br />3 <br />~tl <br />g <br />o r <br />> Ln <br />L <br />' <br />> <br />r <br />0 <br />0 <br />°n <br />O <br />ICU <br />_ <br />0 <br />LO <br />I� <br />■ <br />co <br />Lid <br />Ln <br />N <br />T <br />00 0 <br />00 N <br />r <br />O <br />co <br />M N <br />c <br />0 <br />c <br />c <br />a <br />U J <br />Q p <br />� <br />JOB <br />NO: <br />19-5888 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.