Laserfiche WebLink
ti <br />�100 <br />V_ <br />co <br />q.. <br />ti <br />12 <br />5� <br />T.O.P. <br />HDR HGT. — <br />12 <br />�5 <br />CJ CJ CJ o 0 <br />2nd FIN. N U) _ <br />----------------- <br />------- ----------------- <br />FLR. <br />--- CJ / WEEP 12 CJ / WEEP <br />T.O.M. <br />-----------------------------------3-- — <br />)RHGT.--------- <br />-------------------- <br />ROOF TO BE <br />-------------------- -- <br />0 "' <br />F.FL. <br />9' RIDGE VENT <br />12 <br />5� <br />CENTERED ON <br />DOOR <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />REAR ELEVATION - B1 <br />T.O.P. - <br />HDR HGT. <br />25 SH <br />oZ JF' <br />2nd FIN. N rn = <br />T.O.M. <br />F.FL. <br />SCALE: 1 /4"=1'-0" <br />2'-0" <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />RIGHT ELEVATION - B1 <br />SCALE: 1 /4"=V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />.G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall Include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be Installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water Into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />_1 <br />L� <br />C <br />C_ <br />G _ <br />z_ <br />z <br />Q g <br />� <br />z <br />Ou, <br />�N <br />C) <br />0 <br />ip0 <br />Z0 <br />N O <br />N <br />LULU <br />a <br />f� <br />Z 0 1-.srlR05 <br />W1 <br />N" F <br />Q <br />- <br />o <br />C. `cft <br />R OFF S S\O <br />\ <br />f�iSai14�a11�� <br />To the bast of the Engineer's knowledge, inforrnation and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code <br />Resldentiel 6th Edition. Engineers signature and seal <br />- <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />o <br />Q <br />M <br />_j <br />E <br />as <br />a6• <br />Z <br />FT <br />fu <br />w� <br />go <br />�o <br />$ <br />8 <br />a <br />z <br />�to�, <br />N_ Czo <br />C J <br />W� <br />o124T— <br />L <br />' <br />j <br />\T <br />0 <br />0 <br />r� <br />C:) <br />a <br />m <br />v <br />c <br />~ <br />3 <br />T� <br />v <br />T <br />LO <br />N <br />T <br />oo O <br />00 N <br />� <br />T-- <br />ai <br />E <br />Q <br />M N <br />n <br />o <br />z <br />a <br />U <br />Q p <br />JOB <br />NO : <br />19-5888 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.2 <br />