x <br />N <br />0 <br />r- <br />LO <br />00 <br />N <br />00 <br />LO <br />N04 <br />c <br />N <br />0 <br />a0 <br />N <br />00 <br />W <br />0 <br />r1 <br />00 <br />w <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />NEMA t <br />200 AMP <br />MAIN <br />0 <br />200 amp <br />150 amp <br />copper to lights & outlets <br />copper to 20 amp ckts <br />.2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />POWER CO. FEEDS f <br />INTERSYSTEM ylUAA <br />4 Bare Cu Ground <br />BONDING <br />44 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance With UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />w.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />® <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />H)_ <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />-� <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />Tq <br />TELEVISION (OPTIONAL) <br />T� 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />owl_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />^®^ <br />J <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />WP <br />GFI <br />PATIO <br />WP <br />GFI <br />H.B. <br />/ I i <br />\ —f:AAAIL-1f-R00M <br />\ <br />ROUGH -IN FOR 1 <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRED � \ <br />\ PENDANT AS <br />\PER SPECS <br />-7- <br />_ _/ <br />DIN IN OOM <br />I <br />I ' <br />I <br />l_----- <br />GFI . &GFI <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />I L GFI - <br />I <br />------ --- <br />9 <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />FOYER <br />db <br />H. \ CTFI @ 44" <br />/) A.F.F. <br />Or------------ <br />I <br />I <br />I <br />I <br />I <br />2 CAR GARAGE <br />I <br />I <br />I <br />� I <br />GFI @ 44" GFI FOR <br />A.F.F. GAR. DOOR I <br />GFI I <br />/ I <br />IX / <br />I <br />� � I <br />I <br />� I <br />I <br />I <br />I <br />VERIFY LOCATION L_IRRIGATION _____ <br />ELECTRICAL PANEL L GFI @ 44" A.F.F. <br />VERIFY METER H.B. <br />LOCATION WITH <br />BUILDER <br />WP <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4'=1'-0" <br />(D _r <br />Z M <br />O <br />O <br />Z N <br />Z <br />U) z <br />unn' (D <br />W <br />Q <br />�U — <br />W <br />~ <br />Ln <br />o 0 <br />W E <br />~- 8 <br />M <br />C f6 M <br />O O N <br />000011k <br />_ <br />tliop <br />.]C <br />LO <br />¢ &A <br />Q O <br />I <br />B D® <br />N vc <br />�V <br />'s <br />O N <br />co <br />N <br />�� <br />o <br />`c3 <br />II• d M rn Z <br />LL <br />IJL Z <br />J <br />(� <br />LU=u- o <br />a <br />W UQ a a. <br />in <br />Z o ¢ <br />u N � oAo <br />O <br />m °° <br />ZNgE0 <br />Q <br />Q ° g <br />W N a M <br />O <br />U <br />O <br />❑❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawingscomply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />z0 <br />N <br />O o <br />V) M <br />�>'+ <br />j rp Lr <br />a n <br />W LA <br />Z <br />CL �M <br />pC U Q 00 <br />< § E <br />ZWo <br />W <br />C:) <br />_j <br />0z <br />�o <br />zaa <br />za <br />Z <br />Wz00 <br />Mo-0 <br />oLd WQ� <br />Ozz <br />J <br />�°Zw <br />Q <br />a u- o <br />�lm�o <br />U <br />1..1� <br />Z z <br />z <br />C) <br />Qo <br />zZ <br />g <br />LL <br />w <br />a <br />J <br />LU <br />-0 <br />L <br />U <br />= <br />N0 <br />�a <br />Lu <br />0 <br />LL <br />0� <br />LL <br />a 0 zo <br />I- <br />Q Y <br />�Y� <br />9LL�1pa <br />I\ <br />C <br />G <br />u J C z <br />a3 <br />Q <br />Imo <br />Z <br />LL0go <br />Z <br />r-i <br />Ln <br />a LL <br />W g <br />J <br />Q <br />W <br />Z <br />$r E <br />Lu <br />& z <br />0 <br />� <br />Z <br />R Lan <br />z <br />m <br />N <br />GZ( <br />w <br />J <br />�0 <br />az <br />O <br />00J <br />= <br />17711 <br />T__I <br />a <br />to <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAM ES <br />VERSION NO- 5ol <br />SHEET NO. <br />4.0 <br />