My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3025 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3025 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 5:28:26 PM
Creation date
2/27/2025 11:15:39 AM
Metadata
Fields
Template:
Building Plans
Street #
3025
Location
Kresterbrooke Ln
Contractor
Lennar Homes
Building Plans - Permit #
20164
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
m <br />tb <br />N <br />E <br />0 <br />x <br />a <br />00 <br />N <br />O <br />M <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY' <br />BON <br />TERM I NATIOP <br />NEC 14, 250.94 J <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />opper to lights & outlets <br />opper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />t Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PqF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />KD G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I 4:;Ih <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />o <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />Q EXHAUST FAN/LIGHT COMBINATION <br />FC...._....... <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) SYSTEM <br />CH CHIMES (OPTIONAL) <br />El PUSHBUTTON SWITCH (OPTIONAL) <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />T� 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />�M ELECTRIC METER <br />WWI ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />^®^ <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />I I <br />L_� <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I I <br />UPPER ELECTRICAL PLAN <br />SCALE: %4'=V-0" <br />C� <br />z o <br />— <br />o <br />to <br />z� <br />Q <br />a <br />U) z <br />O <br />Vn)'' (D <br />crs <br />�W w <br />Ow <br />~ <br />E <br />L <br />0 <br />V <br />0) M <br />LLJ <br />t-- EEp <br />— U <br />E2 ;0 M <br />2 O <br />L lL W <br />v <br />Na� <br />P Y <br />Q rn <br />Lo O: <br />'M ¢ O <br />B D. <br />NN C <br />op v 0 <br />o m <br />z <br />�o��� <br />M M � <br />Z <br />Q� Li N O O <br />, J <br />W LL <br />Z v Q n L <br />z <br />OV <br />Z N °`4 <br />�a� <br />m m <br />W a Via <br />N U <br />U � <br />❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />Z� <br />� +' o <br />unMO <br />►> <br />M LLn <br />V) <br />a�:a� <br />Ln <br />Zd <br />V Q 00 <br />§ E <br />Z Z <br />W <br />LU O <br />J <br />�O <br />d' <br />oZ <br />o <br />w� <br />zaa <br />g <br />F— <br />Z <br />w<=X <br />J <br />ZWLUo <br />w(, <br />J <br />yy�zz <br />¢ J <br />Q <br />aa0uo <br />�u-0 <br />�M <br />U <br />ZZ <br />D <br />? <br />K <br />LLI <br />15 <br />I..f� <br />W <br />CL <br />Lr)JLn <br />LU <br />Ln <br />Cr_�Z <br />0 <br />0 <br />= <br />N <br />O <br />92 <br />,J <br />oZ <br />ar, <br />0 <br />J <br />ILL <br /><Y4PQ <br />` <br />Z <br />ma <br />Q <br />Z<o< <br />Z <br />w Z Z >J <br />3 <br />0 <br />Z <br />E�,o <br />Z <br />W <br />Ln <br />Lu a <br />�wOzr <br />a <br />��� <br />--1 <br />r-I <br />LU <br />W <br />5 <br />a w 0 <br />czu z a <br />g <br />8Q <br />0 <br />UR <br />z <br />mZZL <br />N <br />Z <br />oZ� <br />,-11 <br />d <br />Ln <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAM ES <br />VERSION NO. 5ol <br />SHEET NO. <br />4.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.