My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3197 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3197 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 11:59:41 AM
Creation date
2/27/2025 11:17:16 AM
Metadata
Fields
Template:
Building Plans
Street #
3197
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
19306
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VENTED SOFFIT <br />46 SQ. FT. <br />Egg, <br />VENTED SOFFIT <br />28 SQ. FT. <br />VENTED SOFFIT <br />28 SQ. FT. <br />VENTED SOFFIT 31 SQ. FT. <br />ATTIC VENTILATION CALCULATIONS - Al <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />(No Upper Ventilators <br />1/300 Rule <br />Ridge <br />Vent Amt <br />Off -Ridge <br />Req.) <br />(Must Provide Upper Ventilators) <br />(Ft.) <br />Amt. <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT, <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQIN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />required <br />ventilation <br />vented <br />be provided <br />by <br />. <br />Ventilation <br />Ventilation <br />(See Elev ) <br />eSoffiterie <br />needed <br />required <br />soffit <br />upper <br />needed <br />ventilators <br />Main <br />4.000000 <br />2.000000 <br />Floor <br />1080 <br />1037 <br />148 <br />518 <br />37 <br />259 <br />336.0 <br />60.0 <br />276.0 <br />(Zone 1) <br />Main <br />0.0 <br />0.000000 <br />Floor <br />16 <br />15 <br />2 <br />8 <br />1 <br />4 <br />0.0 <br />0.0 <br />(Zone 2) <br />0.0 <br />Upper <br />16.000000 <br />0.000000 <br />Floor <br />1166 <br />1119 <br />160 <br />560 <br />40 <br />280 <br />240.0 <br />(Zone 3) <br />240.0 <br />0.0 <br />"NOTE — <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 5th ED. RESIDENTIAL. <br />VENTED SOFFIT LEGEND <br />771 <br />IF SOFFIT IS LABELED AS "NON -VENTING" FIRE PROTECTION WILL BE INSTALLED <br />AS REQUIRED BY SECTION R302 OF THE FBC 5th EDITION (2014) RESIDENTIAL. IF <br />LABELED AS "VENTED", NO FIRE PROTECTION WILL BE REQUIRED. <br />------- ;.7M <br />VENTED SOFFIT <br />VENTED SOFFIT <br />28 SQ. FT. <br />ZONE-2 <br />ATTIC SPACE <br />16 SQ. FT. <br />VENTED SOFFIT <br />14 SQ. FT. <br />ROOF PLAN <br />SCALE: Y4'=V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SQ. FT. <br />• O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA/ FT. <br />" (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />"Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear R. of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SO. IN. OF NET FREE AREA / VENT <br />"Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) 186.25 = Amount of CPHagin Vents Needed <br />8 <br />U!P <br />Z co <br />—0 <br />Z Co <br />Q <br />J <br />Z <br />cn <br />i--J w <br />� o <br />U — <br />w <br />O C <br />~ <br />o <br />o <br />U <br />0 <br />04 <br />W E <br />-8 <br />Cl) M <br />c N Cl) <br />f`O.ON <br />Ooo <br />_ °' <br />W <br />U <br />U_00 <br />0YP <br />�Y <br />Q 0 <br />u7 O� <br />Q 0 <br />A I <br />".C. <br />i <br />N <br />UA c_N1• W <br />.0 <br />r3No <br />. • <br />W� LL O <br />1'9ES$\ <br />Q <br />Z <br />IL1 <br />i�ta <br />Com <br />W V)) <br />o <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z N <br />0 (D N <br />i>-+HMO <br />M <br />Q Uo) M Ln <br />a cn •� �- <br />z <br />0 <br />f... LL <br />CL .•. <br />C(-� j a -4 <br />a E00 <br />z� M <br />WJ C:) <br />d' <br />Z <br />W� <br />�a <br />Lu<X <br />�180 <br />z� <br />$xw <br />rn <br />v' <br />0�QEi3 <br />00 <br />F-U® <br />L <br />2Z <br />N_ <br />�3 <br />L <br />0 <br />LU <br />0„- <br />,- <br />LL <br />PRE <br />QOwQ <br />Z <br />a E � <br />W <br />J <br />Lei <br />—4 <br />1 LJ.I <br />.. <br />W <br />IN .0 <br />Z u <br />~ <br />i° <br />Q <br />z <br />y� <br />� F <br />In <br />Z <br />L <br />591 <br />rz <br />< 0 <br />=1 0 <br />m <br />O <br />^ <br />g <br />= <br />aW <br />rn <br />T-4 <br />a <br />(n <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSIONNO' <br />10 <br />SHEET NO. <br />5.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.