My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3229 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3229 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 1:00:38 PM
Creation date
2/27/2025 11:17:41 AM
Metadata
Fields
Template:
Building Plans
Street #
3229
Location
Kresterbrooke Ln
Contractor
Lennar Homes
Building Plans - Permit #
20159
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
02 <br />~I <br />Q <br />00 <br />�I <br />E <br />0 <br />S <br />91■ <br />0 <br />d <br />N. <br />HEEL <br />12 <br />5� <br />12 <br />�5 <br />T.O.M. <br />HDR HGT. - <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />12 <br />5� <br />F. FL. ` T <br />---- —---1--------------------- <br />12 <br />7�5 <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />1' 0" <br />- - - - - - - -- - - - - - - - -- i/ --- <br />11 DEDEEIDE11:1 <br />UE E1E:1E:1EFD_1M1:1D <br />fly0 [711uF0_1 <br />14'-0" RIDGE VENT <br />12 <br />zz:::�J5 <br />15'-0" RIDGE VENT <br />FRONT ELEVATION - Al <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />N• <br />--_ F.FL. <br />----------- I --------------------------------------------------------------------------------------------------------------------------------- [— <br />SCALE: 1 /4"=1'-0" <br />LEFT ELEVATION - Al <br />SCALE: 1 /4"=1' <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 11300 provided that at least 40°% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />**CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SO. FT. <br />= > <br />z� <br />z� <br />Ci- <br />U) z <br />V) <br />� C <br />w <br />(DOO <br />Q <br />•V <br />— <br />O "-' <br />is � <br />N <br />o <br />m N <br />w <br />N M <br />r1 CO <br />N <br />0 <br />=Rio 9? <br />-0 ("MJ <br />OO O c� <br />� <br />0 <br />0 <br />o <br />¢ rn <br />o-o <br />5 <br />rn Q o <br />B D® <br />N C ...0 <br />N <br />10 <br />o <br />U) Z W 2n J] <br />W <br />0. <br />U1 UQ <br />io L�_g <br />Z 0 2 _�?5 <br />LL <br />o 0 <br />H <br />wc � W <br />wat+.FnQ .co <br />�S E <br />a <br />z N <br />< 0 :r <br />y. <br />'•, O <br />fa •, ,•' <br />••Oe <br />O F' S t <br />pR E S, <br />� <br />'tWffitt <br />tat'k <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />A <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />0z <br />0 <br />wo <br />z d <br />W <br />fF <br />Z <br />Wa�� <br />�zo0 <br />O <br />Z �U <br />:Dz <br />�-0�w <br />apm <br />O ceo <br />A <br />'�` <br />V W FW N <br />L <br />W <br />J <br />I8 LU <br />z� <br />r <br />� <br />W <br />a U <br />f Z <br />M <br />O <br />0 <br />a <br />J W <br />U <br />_ <br />Q <br />µ1he <br />411 <br />Xraa <br />O <br />U 0.,., <br />Q <br />O O <br />Z <br />W W <br />°O O <br />CRd2� <br />L U <br />J <br />In <br />r-+l <br />LLI <br />lJ.! <br />0 c z o <br />N t- u <br />u <br />Q <br />z <br />z <br />Z <br />t <br />zo <br />m <br />O <br />06 <br />Z <br />g <br />UJ <br />= <br />0 <br />-z <br />,--I <br />a <br />cn <br />s <br />SCALE : AS NOTED <br />DATE : 6/19/2018 <br />TECH: MJAMES <br />VERSION No' 4n0 <br />SHEET NO. <br />3.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.