My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3229 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3229 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 1:00:38 PM
Creation date
2/27/2025 11:17:41 AM
Metadata
Fields
Template:
Building Plans
Street #
3229
Location
Kresterbrooke Ln
Contractor
Lennar Homes
Building Plans - Permit #
20159
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Do <br />0 <br />Eo <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />N. <br />TC)M — <br />c <br />a <br />12 <br />5� <br />15'-0" RIDGE VENT <br />12 <br />�5 <br />EXTENDED <br />OVERHANG TO <br />BE CENTERED - <br />ON DOOR <br />14'-0" RIDGE VENT <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />------------ <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP. ) <br />12 <br />�5 <br />REAR ELEVATION - Al <br />T.O.M. <br />HDRHGT.4-4, — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br />TEXTURED 1'-0" <br />CEMENTICIOUS TEXTURED <br />ON C.M.U. CEMENTICIOUS <br />ON IOUS <br />FINISH 2 0 <br />(TMP) FINISH ON C.M.U. <br />(TYP. ) <br />-------------- <br />0 <br />CV <br />to <br />W RIGHT ELEVATION - Al - <br />SCALE: 1 /4"=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 11300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SQ. FT. <br />UI �_ <br />Z M <br />0 <br />— o <br />z�z <br />-i <br />a <br />E3 <br />U) <br />(In (D <br />w <br />°U — <br />pw <br />o <br />C) <br />o Cl) <br />CO N <br />w <br />� E <br />— <br />ar r> <br />tm M <br />co <br />N <br />C) <br />_O <br />r"o°Oo <br />o <br />�L rn <br />Q 71 <br />rn Q o <br />AI <br />B D• <br />N C H D C <br />� <br />I <br />N N <br />m <br />z <br />W �N�Z � z <br />RU <br />U) Ili_ J C a <br />=Z <br />~o . Lcl w <br />W <br />o E9� <br />o 6 d <br />fp •' % <br />W <br />'. 0. <br />•. F� :: `!Z1 <br />%��✓✓j,�a'� <br />O F E S S\O\\ \\N <br />�'�°'f►r►Init►u����� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />L N A R <br />4600 W, Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />o <br />171 <br />�a <br />LLJ <br />z'L <br />f <br />a:CL <br />z <br />O <br />w <br />0 <br />oo� <br />Q <br />z <br />S J <br />o-w� 1 <br />Ovw <br />w <br />m V <br />O <br />J <br />ZZ <br />i <br />^Q <br />LL <br />z <br />LOU <br />Ce <br />z <br />C <br />\� <br />3 <br />J <br />T <br />Q <br />o <br />G V <br />Q <br />Jlw. <br />W <br />fo <br />w5zma <br />1,�V <br />Z a Z <br />Q¢wn: <br />E <br />$°fu- <br />z <br />Z <br />Cr �Je 2 <br />W <br />J <br />L0 <br />ri <br />Q <br />6i <br />z <br />aLu Z o <br />u <br />N <br />z <br />aZ <br />m <br />0o <br />z <br />g <br />� <br />�o� <br />W <br />o <br />= <br />T__1 <br />12 <br />Ul <br />o <br />SCALE : AS NOTED <br />DATE : 6/19/2018 <br />TECH: MJAMES <br />VERSION NO. 4n0 <br />SHEET NO. <br />3.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.