My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3292 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3292 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:33:35 AM
Creation date
2/27/2025 11:19:33 AM
Metadata
Fields
Template:
Building Plans
Street #
3292
Location
Kresterbrooke Ln
Contractor
Lennar Homes
Building Plans - Permit #
20410
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LO <br />I <br />Q <br />E <br />S <br />co <br />a <br />tZ <br />00 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />NEMA 1 <br />200 AMP <br />METER <br />M�AI�N <br />200 amp <br />150 amp <br />POWER CO. FEED-- <br />INTERSYSTEM <br />BONDING o <br />TERMINATION PER 7I <br />NEC 14, 250.94 J <br />#14 copper to lights & outlets <br />#12 copper to 20 amp clos <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />or 4/0 SER Alu <br />—4 Bare Cu Ground <br />#4 GROUNDING WIRE <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />----------------------------------------------- <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PEPP <br />DUPLEX OUTLET ABOVE COUNTER <br />F�Fw.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />FFwF <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />—� <br />TRACK LIGHT <br />j <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�Da <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />TV 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />,CL <br />ELECTRIC PANEL <br />_i <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />^® <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />C� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(9�311 <br />(1) PHONE LINE, (1) DATA PORT <br />WP DISC. <br />GFI H.B. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unman ncn ommro <br />SYSTEM <br />LOCATION WITH <br />BUILDER <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4'=1'-0" <br />0 <br />Z M <br />— o <br />Q <br />GL, <br />U) <br />V) <br />(D <br />4— J W LU <br />�a <br />O W <br />t ) <br />m <br />F- <br />N <br />v I <br />m N <br />W <br />py� Cl)C N M <br />Zai <br />pao <br />U" <br />0 o <br />N Y 8 <br />0 <br />w <br />v Qv <br />rn ¢ o <br />B D® <br />N'C'B�D�C <br />N �O <br />Z J� ] C? z <br />a_63; <br />UA <br />LU <br />_LU <br />0 <br />/� 0 <br />�4< <br />O � m <br />Z N M Er' <br />a�— N w a Q <br />LL IW NQco C Ca <br />� U <br />U <br />Ii <br />WWW.FDSENG.com <br />0 <br />P <br />0 <br />N <br />0 <br />M <br />ti <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />4600 W. Cypress St, Suite 200 ( Tampa, FL 33607 <br />www.LennarTampa.com <br />00 <br />zQ <br />a� <br />�F <br />Z <br />w < K <br />8 o <br />Q <br />U 4 <br />^J <br />LL <br />tZ-0.ZQ <br />S in Z <br />J <br />Q� <br />to <br />�o� <br />� <br />n <br />U <br />8W" <br />m <br />ZZ <br />L <br />(� <br />z O <br />Q U <br />�z <br />WCZL <br />Z <br />J <br />r" ( <br />LL <br />O <br />_ <br />TI <br />O <br />J <br />W <br />µOµ1OO <br />O � <br />� <br />z <br />a 0 <br />Po, <br />a <br />zz <br />a g <br />O <br />Z <br />I\ <br />u pu u <br />Z <br />W <br />Lr) <br />t1J <br />'< a z <br />Q <br />J <br />r--I <br />ILL] <br />2:Y <br />Ln <br />Q <br />00 <br />Q <br />Z <br />ZQZ <br />�,r.�/��l <br />�j <br />a o <br />IIL <br />0o <br />g <br />W <br />= <br />� <br />,--i <br />a <br />to <br />o <br />SCALE : AS NOTED <br />DATE : 7/30/2018 <br />TECH: MJAM ES <br />VERSION NO. 4x0 <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.