Laserfiche WebLink
`v <br />Ir <br />W <br />v <br />v <br />x <br />rn <br />0 <br />cV <br />r` <br />i" <br />L0 <br />I <br />00 <br />i <br />E5 <br />rn <br />a� <br />lr <br />W <br />a> <br />v <br />S <br />rn <br />0 <br />0 <br />J <br />LO <br />L0 <br />DD <br />r" <br />N <br />O <br />W <br />1'-0" <br />ATTIC VENTILATION CALCULATIONS - Al <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />(See Elev ) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />29.00000 <br />1.000000 <br />Floor <br />2373 <br />2278 <br />325 <br />1139 <br />81 <br />570 <br />0 <br />573.0 <br />435.0 <br />138.0 <br />(Zone 1) <br />"NOTE*' <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN <br />SCALE: %'=V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 11300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN* <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN, OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />CD "' <br />Z M <br />— o <br />z (D <br />z <br />Q <br />z <br />Mi <br />f) <br />•V — <br />O w <br />ZD <br />o2 <br />a- <br />co <br />C) <br />0� <br />00 N <br />W <br />— <br />4) M <br />C M M <br />— U <br />skF <br />O O N <br />U <br />LL00 <br />5 <br />Cn <br />0 <br />Q rn <br />o- o <br />v Qv <br />rn ¢ o <br />B D® <br />N C B-D C <br />_ N <br />YI OO M O ib <br />v O O � <br />Z Lu M��z tz, z° <br />o. <br />LY <br />LY V ��LLo <br />w O <br />Z O ., C{CMD <br />,arr� <br />wrW VeSEVIS,IS Sc�a <br />�� <br />qa• � � <br />C9 <br />�� <br />a ,•ea <br />,fir ' `y �• ••• � <br />s0� <br />ESF, <br />:. <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />4600 W. Cypress St, Suite 2001 Tampa, FL 33607 <br />www.LennarTampa.com <br />oz <br />0 <br />�o <br />z ¢ <br />of <br />f <br />aF,, <br />w¢c X <br />U <br />Z U 0 <br />z Q <br />�2Zww <br />a0.2�R <br />��� O <br />W. <br />U Lu N <br />��-- <br />F <br />W <br />C <br />z 0 <br />} U <br />z <br />�3 <br />1� <br />o <br />a <br />J W <br />Lg <br />O <br />7-J <br />�ou00 <br />1 <br />O <br />UOm'a� <br />uU <br />a 0 ¢ <br />t'V <br />cc <br />z¢Z< <br />�oU <br />z <br />-0 W <br />0 <br />J <br />T- 4 <br />W <br />LLJ <br />Q <br />¢ W !t T) <br />a z o <br />$ate <br />00 <br />a <br />z <br />z <br />Paz <br />tl <br />0 0 <br />m <br />� <br />�y�� <br />w <br />4z <br />.J <br />Wun <br />= <br />- Z <br />4 f <br />SCALE : AS NOTED <br />DATE : 7/30/2018 <br />TECH: MJAM ES <br />VERSION N0. 4mO <br />SHEET NO. <br />5.0 <br />wlxiil') IlLlI�IT, t-hildilh <br />