My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36417-36437 Campfire Ter
Zephyrhills
>
Building Department
>
Building Plans
>
36417-36437 Campfire Ter
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 3:29:34 AM
Creation date
2/27/2025 11:22:27 AM
Metadata
Fields
Template:
Building Plans
Street #
36417-36437
Location
Campfire Ter
Contractor
Lennar Homes
Building Plans - Permit #
6467-6472
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors, <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />zh, DUPLEX OUTLET ABOVE COUNTER <br />Fff <br />1 42� WEATHERPROOF DUPLEX OUTLET <br />rK:;1'W P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />?4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />3:� CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />#P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />lcl� <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHIMES (OPTIONAL) <br />FCH <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />FT v] TELEVISION (OPTIONAL) <br />FT-V] 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />WWI ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />3" VTR ji� <br />JIL <br />OPT. <br />LAV <br />r LAV <br />L"v <br />JHANSON I <br />BOX I <br />3 <br />W/C <br />LAV <br />S SHOWER <br />.j HOWER <br />TUB/ <br />W/C SHOWER <br />---_217Q� <br />STUDOR <br />VENTTDBL SINK <br />L7_j W1 DISP. <br />LAV WIC <br />PLUMBING RISER, <br />SCALE:NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />- <br />UNIT -A 1532 (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />AT 960 WATTS <br />1 <br />960 <br />-DISPOSAL <br />HEATER AT 5500 WATTS <br />1 <br />smo <br />-WATER <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />AT 1200 WATTS <br />1 <br />1200 <br />-MICROWAVE <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />5200 <br />TOTAL: 31768 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />1��P Serial Cable <br />NEMA <br />3R <br />Power Co. Feed ---- 1-1 L #4 Solid COPPER Ground <br />C.O. <br />Intersystem Bonding <br />Termination Per <br />NEC 17, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />ro <br />------------------------- <br />OUTDOOR LIVING <br /><A\ /^> <br />INSTALL LIGHT <br />ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT WP <br />GFI <br />1 117% <br />(2)GFI <br />M I <br />DINING <br />KI TCHEN) <br />F — — — <br />— — — GFI_d <br />SWITCH FOR - <br />DISPOSAL IN CAB <br />UNDER SINK <br />GREAT ROOM <br />>ROUGH -IN\ <br />FOR OPT ' <br />FAN/LIGHT <br />=0 <br />ooll <br />W <br />FOYER <_ <br />DB <br />aB <br />ENtRY I Wpo— <br />L I GHT AS (!?)��G F I <br />PEF R SPEC :S <br />'S <br />DB & GFI TO <br />—7 <br />BE ALIGNED <br />VERTICALLY <br />LU <br />P ?>> <br />LU <br />0 X <br />Uj <br />_5 <br />Z( <br />LU 0 <br />> _j co <br />raF-L — _1 <br />I <br />I UPSTAIRS t <br />GFI <br />@ 44" <br />H <br />A.F.F. <br />0 <br />GARAGE <br />GARAGE <br />LIGHT AS <br />TER SPECS <br />GARAGE <br />DOOR <br />GFI <br />r- — — <br />— — <br />— — — — — — — — — — — -- <br />Z W <br />7/1 <br />Z <br />P < <br />< <br />3 <br />Uj <br />__1 <br />> Uj <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL - UNIT -A 1532_ <br />SCALE: Y4"=1'-0" <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />F__ — — — — — — — — — — — — — — — — — ___1 <br />L <br />2ND ELECTRICAL - UNIT -A 1532_ <br />SCALE: Y4"=V-1)" <br />C%j <br />fz <br />C= <br />C,**' <br />C14 <br />> <br />CL) C3 <br />CP <br />M <br />C11,> <br />C%j <br />C::0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 <br />Ronda Building Code <br />- <br />Residential <br />7th Edition, Engineer's signature and seal <br />is only for <br />the structural <br />engineering portions <br />of the drawing pages beadng <br />Engineers <br />signature and seal. <br />U) <br />Iggg <br />ff <br />FRI <br />Aga <br />'5- E <br />cD <br />8 LO <br />. :: <br />— I- <br />6 '0 <br />& <br />0 <br />W <br />.0 <br />0 c? US <br />E� <br />Lu <br />N 0 Q_ LU <br />C') zT <br />c- <br />�Nk <br />L-Lj <br />Z <br />f 0 S) <br />Z <br />_C Co 0 <br />C? — of <br />M uj <br />W <br />q <br />0 <br />co (� �: Z <br />W <br />Z <br />IL <br />0 Q� 0 W <br />0 Z < L) X: <br />C) <br />< <br />jq, <br />Z <br />b <br />n - W <br />SIMON, <br />V) <br />(Du <br />LU <br />0 <br />Ln <br />LIJ 8� <br />L11 <br />8 <br />C) <br />cc) <br />cl_� <br />C6 E <br />E 0 <br />z <br />�o <br />'z <br />< <br />r6 <br />n� <br />uo <br />cc=3 E <br />t <br />CO 00 <br />zz <br />'0 <br />0 <br />cD <br />c_� <br />18 1 <br />0 <br />CO <br />W <br />z <br />(1)00 <br />> <br />_17 <br />ca <br />M <br />I:d- <br />L_ <br />(D <br />C.0 <br />(.0 <br />CN <br />M <br />C:) <br />LL <br />L0 <br />C-4 <br />CN <br />Cr <br />E <br />80 <br />_;2 <br />.2 <br />U) c`3 <br />3 <br />C:> <br />CN <br />LO <br />r- <br />C1111i <br />0 <br />1:T <br />LO <br />co Cl) <br />C? <br />LO <br />N <br />(5 <br />M CD <br />a) C\I <br />0-) <br />LO <br />E <br />CY) CY) <br />0 <br />as <br />=3 <br />U') <br />Z <br />E <br />CU <br />c: <br />2 <br />13- <br />E <br />0 16 <br />_j <br />_0 lc� <br />< <br />_j <br />JOB <br />NO 23-04725-04730 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />
The URL can be used to link to this page
Your browser does not support the video tag.