ELECTRICAL SPECIFICATION 3" VTR <br />NOTES: 3" VTR JIL <br />JIL <br />ELECTRICAL CONTRACTOR I <br />I <br />MUST VERIFY WITH THE I <br />SPECIFICATIONS FOR THE TYPE I <br />OF FIXTURE TO BE USED. LIGHT OPT. <br />FIXTURES SHOWN ARE FOR LAV LAV <br />L'�'v <br />LHANSON <br />LOCATION PURPOSES. OX <br />BOX <br />3" <br />W/C <br />LAV <br />SHOWER <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DIFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smokelcarbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6'of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FE5`__W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />I /—\ <br />P;EFG.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />1 4:) <br />rwl-- <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />3:� <br />CEILING MOUNTED LIGHT FIXTURE <br />77-N <br />N—A <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />+P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />MQ <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />[CH] <br />CHIMES (OPTIONAL) <br />PH <br />PUSH BUTTON SWITCH (OPTIONAL) <br />F0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />@ <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />FTV1 <br />TELEVISION (OPTIONAL) <br />FTV] 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />-MI7-j <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />GG) <br />(1) PHONE LINE, (1) DATA PORT <br />TUB/ <br />W/C SHOWER <br />OUTDOOR LIVING <br />STUDOR C.O. <br />ULU'�' DBL SINK <br />DBL SINK < > <br />VENT W1 �P INSTALL LIGHT <br />W1 DISP. ROUGH -IN <br />2t] <br />FOR OPT. <br />LAV WIC �3 WP <br />WIC 3" FAN/LIGHT GFI <br />�,2"j 1 lom <br />KW <br />PLUMBING RISER <br />SCALE:NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS- <br />UNIT-C 1624 (1624) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1625 S.F. <br />4875 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10875 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33935 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9574 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />1 5200 <br />TOTAL: 31878 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 13: <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />�E T EOR MA N <br />F 1 0-2 0 A P Tr ,--Serial Cable <br />3R <br />Power Co. Feed 1-1 [ #4 Solid COPPER Ground <br />Intersystem Bonding <br />Termination Per <br />NEC 17, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6'apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 -17, LOCAL CODES AND THE LOCAL POWER CO. <br />DISCONNECT <br />1ST ELECTRICAL - UNIT-C 1624 <br />SCALE: Y4"=1'-0" <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />— SPECS <br />F__ <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />— — __1 <br />2ND ELECTRICAL - UNIT-C 1624 <br />SCALE: J/4"=V-0" <br />Uj <br />2 C= <br />C <br />C_ Cc= <br />1-00 <br />M <br />LL_ <br />C= <br />E <br />r J�j <br />cm <br />C=) <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition. Engineers signature and seal <br />is only <br />for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />E 0 <br />­8 00 <br />N <br />0 <br />a) <br />o? A <br />X Lu Lu <br />EL <br />14 <br />C: _j u_ <br />CU <br />u_ U) Z <br />z 3Z 0 <br />Z <br />— <br />, 6 3: 0 Z) <br />= M '�T 0 Y <br />— 9 — M 3: <br />Ig <br />W <br />:E; 0 <br />D % C-4 < <br />0 2 r— M <br />W <br />U5 <br />Z <br />Z <br />IL <br />00 6 ct� 0 �q <br />Z < 0 <br />() C/) <br />< <br />0 (5 13131:1 <br />Z <br />LU <br />Q) Cl) <br />< <br />13 <br />U) V) <br />M <br />- <br />( 1) <br />0 0 <br />4—d <br />C_/�' <br />LU <br />ca <br />U <br />Q) <br />0 <br />V) <br />_LU <br />E <br />< <br />C�' <br />CjD <br />cl� <br />Cl> <br />< <br />E <br />Q <br />< M <br />E 8 <br />CU <br />< 0 <br />, <br />. 8 <br />,z, E <br />C15, <br />0 < <br />E <br />< <br />t <br />C: <br />Z' <br />2 <br />< 00 <br />W <br />C� <br />co <br />0 <br />10 <br />0 <br />00 <br />U <br />co <br />CN <br />0 <br />C.0 <br />C.0 <br />C-�j <br />M <br />CO CD <br />LL <br />Ln <br />04 <br />0- <br />CN <br />1 <br />Cr <br />E <br />50 <br />_k <br />.2 <br />U) mo <br />C114 <br />LO <br />r- <br />CN <br />0 <br />1:3" <br />LO <br />-0 <br />(.0 co <br />LO <br />C%4 <br />CD <br />ZD <br />.0 <br />Q0 <br />co C:) <br />6 <br />E <br />1 <br />'r— <br />co co <br />6 <br />cc <br />LO <br />Z <br />Z <br />E r— <br />C <br />M <br />a. 1 <br />E 4j <br />0 0 <br />0 _j <br />iv CU <br />< 0 <br />JOB <br />NO: 23-04725-04730 <br />SCALE <br />AS NOTED <br />SHEET NO. <br />11.2 <br />