My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36880 Precita Ter
Zephyrhills
>
Building Department
>
Building Plans
>
36880 Precita Ter
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 7:14:56 PM
Creation date
2/27/2025 11:23:37 AM
Metadata
Fields
Template:
Building Plans
Street #
36880
Location
Precita Ter
Contractor
KHFO LLC
Building Plans - Permit #
3888
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br />a <br />ROOF PLAN <br />SCALE: 1 /4"=1'-0" <br />a <br />LOWER ROOF ATTIC VENTILATION <br />ATTIC AREA <br />TOTAL VENTING REQUIRED <br />120 SQ. FT. <br />1 IS SQ. IN. <br />LINEAR FT. SOFFIT REQ'D AT 6.57 SO. IN. / LF. <br />1 18 LF. <br />R806.2:THE MINIMUM NET FREE VENTILATING AREA SHALL <br />NOT BE LESS THAN 1/150 OF THE VENTED SPACE. <br />UPPER ROOF ATTIC VENTILATION <br />ATTIC AREA <br />TOTAL VENTING REQUIRED <br />1611 SQ. FT. <br />773 SQ. IN. <br />UPPER VENT 40% NET VENT MIN. <br />309 SQ. IN. <br />UPPER VENT 50% NET VENT MAX. <br />387 SQ. IN. <br />UPPER VENTS REQUIRED <br />48" TAMCO OFF -RIDGE VENT (138 SI NET FREE) <br />3 VENTS <br />NET FREE AREA UPPER ROOF VENTING <br />414 SQ. IN. <br />NET FREE AREA SOFFIT VENTING <br />414 SQ. IN. <br />LINEAR FT. SOFFIT REQ'D AT 6.57 SQ. IN. / LF. <br />63 LF. <br />NOTE: LOCATE RIDGE VENTS 2'-0" OFF ALL <br />HIPS RIDGES OR VALLEYS, MIN., TYP. <br />R806.2:THE MINIMUM NET FREE VENTILATING AREA SHALL <br />NOT BE LESS THAN 1/150 OF THE VENTED SPACE. <br />EXCEPTION: THE MINIMUM NET FREE VENTILATION AREA <br />SHALL BE 1/300 OF THE VENTED SPACE PROVIDED NOT <br />LESS THAN 40 PERCENT AND NOT MORE THAN 50 <br />PERCENT OF THE REQUIRED VENTILATING AREA IS <br />PROVIDED BY VENTILATORS LOCATED IN THE UPPER <br />PORTION OF THE ATTIC OR RAFTER SPACE. UPPER <br />VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 <br />FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF <br />THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE <br />OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR <br />CORNICE VENTS. WHERE THE LOCATION OF WALL OR <br />ROOF FRAMING MEMBERS CONFLICTS WITH THE <br />INSTALLATION OF UPPER VENTILATORS, INSTALLATION <br />MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR <br />HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. <br />UNDERLAYMENT APPLICATIONS SHALL BE INSTALLED IN <br />ACCORDANCE WITH SECTION R905.1.1 <br />FOR ASPHALT SHINGLES REFERENCE TO SECTION R905.2 <br />FOR TILE ROOFING REFERENCE TO SECTION R905.3 <br />Ir <br />W <br />>- _ m <br />ELI <br />3�O>.F- <br />5; < o <br />LU 0 F- <br />cnUWw <br />2 � <br />J <br />�LLJ <br />x IY Iz <br />YOI-Z <br />LL00C6 <br />zzz~Lu <br />z_ <br />L J QQ � J <br />wa.=cra <br />=ZLLU) <br />?o <br />�HQcz <br />cl <br />ZO <br />6 Q d^ <br />Q o <br />O <br />� a <br />Q <br />0 <br />l� <br />V <br />Z <br />0 <br />a. <br />O <br />O <br />O <br />0� <br />cn <br />w <br />w <br />0 <br />x <br />z <br />0 <br />tn <br />W <br />to <br />08 <br />� <br />[a <br />azaaaaa <br />JAN 1 2022 <br />COMMUNITY: <br />LINKS A CALUSA <br />SPRINGS <br />PLAN # 6103 <br />RELEASED: 1/18/22 <br />SHEET <br />A3. I <br />, I w i h.eiLA,, [un UAIIAI lila r n n9. 11p IA FIT— 91 <br />
The URL can be used to link to this page
Your browser does not support the video tag.