My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7866 Gall Blvd (7)
Zephyrhills
>
Building Department
>
Building Plans
>
7866 Gall Blvd (7)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 10:07:51 AM
Creation date
2/18/2025 3:14:54 PM
Metadata
Fields
Template:
Building Plans
Street #
7866
Location
Gall Blvd
Contractor
IContractors
Building Plans - Permit #
5463
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mandatory Requirements (as applicable) Requirements compiled by US Department of Energy <br />and Pacific Northwest National Laboratory. Adopted <br />for FBC with permission. Not all may be <br />applicable <br />Topic Section Component Description Yes <br />N/A <br />Exempt <br />1. To be checked by Designer or Engineer <br />Insulation 5.8.1.2 Envelope <br />Below -grade wall insulation installed per <br />manufacturer's instructions. <br />Insulation 5.8.1.2 Envelope <br />Slab edge insulation installed per manufacturer's <br />instructions. <br />Insulation 5.5.3.5 Envelope <br />Slab edge insulation depthAength. <br />11IJ <br />❑ <br />Insulation 6.4.4.1.5 Envelope <br />Bottom surface of floor structures incorporating <br />0IJ <br />radiant heating insulated to >=R-3.5. <br />SYSTEM —SPECIFIC 6.5.1, 6.5.1.1, Mechanical <br />Air economizers provided where required (and not <br />❑ <br />19 <br />6.5.1.3, 6.5.1.4 <br />exempted), meet the requirements for design <br />capacity, control signal, ventilation controls, <br />high -limit shut-off, integrated economizer control, <br />and provide a means to relieve excess outside air <br />during operation. <br />SYSTEM —SPECIFIC 6.5.1, 6.5.1.2, Mechanical <br />Water economizers provided where required, <br />�-�{ <br />IR <br />6.5.1.2.1, 6.5.1.3 <br />meet the requirements for design capacity, <br />maximum pressure drop and integrated <br />economizer control. Capable if providing 100% of <br />the expected system cooling load when outdoor <br />SYSTEM —SPECIFIC 6.5.1.5 Mechanical <br />air — 50F. <br />Economizer operation will not increase heating <br />❑ <br />energy use during normal operation. <br />SYSTEM —SPECIFIC 6.5.2.2.1 Mechanical <br />Three -pipe hydronic systems using a common <br />13 <br />return for hot and chilled water are not used. <br />SYSTEM —SPECIFIC 6.5.2.2.3 Mechanical <br />Hydronic heat pump systems connected to a <br />common water loop meet heat rejection and heat <br />addition requirements. <br />SYSTEM —SPECIFIC 6.5.1.6 Mechanical <br />Water economizer specified on hydronic cooling <br />and humidification systems designed to maintain <br />inside humidity at >35 OF dewpoint if an <br />economizer is required. <br />SYSTEM —SPECIFIC 6.5.3.1.1 Mechanical <br />HVAC fan systems at design conditions do not <br />10 <br />exceed allowable fan system motor nameplate hp <br />or fan system bhp. <br />SYSTEM —SPECIFIC 6.5.3.1.2 Mechanical <br />HVAC fan motors not larger than the first available <br />10 <br />motor size greater than the bhp. <br />HVAC 6.5.6.1 Mechanical <br />Exhaust air energy recovery on systems meeting <br />1110 <br />❑ <br />Tables 6.5.6.1-1, and 6.5.6.1-2. <br />SYSTEM —SPECIFIC 7.4.2 Mechanical <br />Service water heating equipment meets efficiency <br />10 <br />requirements. <br />SYSTEM —SPECIFIC 7.5.2 Mechanical <br />Service water heating equipment used for space <br />Gd <br />heating complies with the service water heating <br />equipment requirements. <br />Insulation 5.8.1.2 Envelope <br />Above -grade wall insulation installed per <br />R1 <br />manufacturer's instructions. <br />Insulation 5.8.1.2 Envelope <br />Floor insulation installed per manufacturer's <br />13 <br />10 <br />instructions. <br />Controls 10.4.3 Mechanical <br />Elevators are designed with the proper lighting, <br />10 <br />ventilation power, and standby mode. <br />SYSTEM —SPECIFIC 6.4.1.1, 6.8.1-7a Mechanical <br />Heat Rejection Equipment: Minimum Efficiency <br />Requirement >=40.2 gpm/hp . <br />SYSTEM —SPECIFIC 6.4.1.1, 6.8.1-7b Mechanical <br />Heat Rejection Equipment: Minimum Efficiency <br />61 <br />13 <br />Requirement >=20.0 gpm/hp. <br />SYSTEM —SPECIFIC 6.4.1.1, 6.8.1-7c Mechanical <br />Heat Rejection Equipment: Minimum Efficiency <br />10 <br />Requirement > 16.1 gpm/hp. <br />EnergyGauge Summit® Fla/Com-2020. Effective Date: Dec 31, 2020 <br />Florida Building Code, Seventh Edition (2020) - Energy Conservation C402.1.1: ASHRAE Energy Cost Budget Option <br />5/19/2022 Page 8 of 24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.