Laserfiche WebLink
SYSTEM —SPECIFIC 6.4.1.1, 6.8.1-7d Mechanical <br />Heat Rejection Equipment: Minimum Efficiency <br />Requirement >=7.0 gpm/hp <br />SYSTEM —SPECIFIC 6.5.5.3 Mechanical <br />Centrifugal fan open -circuit cooling towers having <br />0ICJ ❑ <br />combined rated capacity — 1100 gpm meets <br />minimum efficiency requirement: >=38.2 gpm/hp. <br />SYSTEM —SPECIFIC 6.4.1.1, 6.8.1-7e Mechanical <br />Heat Rejection Equipment: Minimum Efficiency <br />Requirement >=176 kBtu/h-hp <br />SYSTEM —SPECIFIC 6.4.1.1, 6.8.1-7f Mechanical <br />Heat Rejection Equipment: Minimum Efficiency <br />❑ 16 ❑ <br />Requirement > 157 kBtu/h-hp w/ R-507A test <br />fluid. <br />SYSTEM —SPECIFIC 6.4.1.1, 6.8.1-7g Mechanical <br />Heat Rejection Equipment: Minimum Efficiency <br />0 16 ❑ <br />Requirement > 134 kBtu/h-hp w/ Ammonia test <br />fluid.. <br />SYSTEM —SPECIFIC 6.4.1.1, 6.8.1-7h Mechanical <br />Heat Rejection Equipment: Minimum Efficiency <br />Requirement > 135 kBtu/h-hp w/ R-507A test <br />fluid. <br />SYSTEM —SPECIFIC 6.4.1.1, 6.8.1-7i Mechanical <br />Heat Rejection Equipment: Minimum Efficiency <br />13 16 0 <br />Requirement >=110 kBtu/h-hp w/ Ammonia test <br />fluid. <br />SYSTEM —SPECIFIC 7.5.3 Mechanical <br />Gas -fired water -heating equipment installed in <br />new buildings: where a singular piece of <br />water -heating equipment — 1,000 kBtu/h serves <br />the entire building, thermal efficiency must be >_ <br />90 Et. <br />Where multiple pieces of water -heating <br />equipment serve the building with combined rating <br />is — 1,000 kBtu/h, the combined <br />input -capacity -weighted -average thermal <br />efficiency, thermal efficiency must be >= 90 Et. <br />Exclude input rating of equipment in individual <br />dwelling units and equipment — 100 kBtu/h. <br />SYSTEM —SPECIFIC 6.5.3.2.4 Mechanical <br />Return and relief fans used to meet Section <br />�-yJ� <br />0 1_11 <br />6.5.1.1.5 have relief air rate controlled to maintain <br />building pressure through differential supply -return <br />airflow tracking. Systems with supply fans allowed <br />to control the relief system based on oudoor air <br />damper position. Fans have variable speed <br />control or other devices for managing total <br />retum/relief fan system demand per section <br />threshold. <br />HVAC 6.5.2.6 Mechanical <br />Units that provide ventilation air to multiple zones <br />13 El ❑ <br />and operate in conjunction with zone heating and <br />cooling systems are prevented from using heating <br />or heat recovery to warm supply air above 60°F <br />when representative building loads or outdoor air <br />temperature indicate that most zones demand <br />cooling. <br />HVAC 6.5.4.7 Mechanical <br />Chilled -water cooling coils provide a 15°F or <br />0El ❑ <br />higher temperature difference between leaving <br />and entering water temperatures and a minimum <br />of 57°F leaving water temperature at design <br />conditions <br />SYSTEM —SPECIFIC 6.5.3.4 Mechanical <br />Parallel -flow fan -powered VAV air terminals have <br />�-�{ <br />0 16 ❑ <br />automatic controls to a) turn off the terminal fan <br />except when space heating is required or if <br />required for ventilation; b) turn on the terminal fan <br />as the first stage of heating before the heating coil <br />is activated; and c) during heating for warmup or <br />setback temperature control, either operate the <br />terminal fan and heating coil without primary air or <br />reverse the terminal damper logic and provide <br />heating from the central air handler through <br />primary air. <br />EnergyGauge Summit® Fla/Com-2020. Effective Date: Dec 31, 2020 <br />Florida Building Code, Seventh Edition (2020) - Energy Conservation C402.1.1: ASHRAE Energy Cost Budget Option <br />5/19/2022 Page 9 of 24 <br />