Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30850239 <br />TTH27-33 <br />T01 <br />Hip Girder <br />2 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Mon Jun 19 12:29:31 2023 Page 2 <br />I D: tPuYCeVfQTfYt30C?ZvfnpzlG U H-RfC?PSB7DH q3 N SgPgn L8w3u ITXbG K WrC Doi7 J4zJ C?f <br />NOTES- (11) <br />10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 124 lb down and 158 lb up at 6-2-6, 125 lb down and 153 lb up at <br />8-3-2, 125 lb down and 153 lb up at 10-3-2, 124 lb down and 153 lb up at 12-3-2, 124 lb down and 153 lb up at 14-3-2, 124 lb down and 153 lb up at 16-3-2, 124 lb <br />down and 153 lb up at 18-3-2, 124 lb down and 153 lb up at 20-3-2, 124 lb down and 153 lb up at 21-6-0, 124 lb down and 153 lb up at 22-8-14, 124 lb down and 153 lb <br />up at 24-8-14, 124 lb down and 153 lb up at 26-8-14, 124 lb down and 153 lb up at 28-8-14, 124 lb down and 153 lb up at 30-8-14, 125 lb down and 153 lb up at <br />32-8-14, and 125 lb down and 153 lb up at 34-8-14, and 225 lb down and 372 lb up at 36-9-10 on top chord, and 141 lb down at 6-2-6, 56 lb down at 8-3-2, 56 lb down <br />at 10-3-2, 56 lb down at 12-3-2, 56 lb down at 14-3-2, 56 lb down at 16-3-2, 56 lb down at 18-3-2, 56 lb down at 20-3-2, 56 lb down at 21-6-0, 56 lb down at 22-8-14, <br />56 lb down at 24-8-14, 56 lb down at 26-8-14, 56 lb down at 28-8-14, 56 lb down at 30-8-14, 56 lb down at 32-8-14, and 56 lb down at 34-8-14, and 141 lb down at <br />36-8-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. <br />11) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of <br />the building designer per ANSI TPI 1 as referenced by the building code." <br />LOAD CASE(S) Standard <br />1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 <br />Uniform Loads (plf) <br />Vert: 1-3=-54, 3-9=-54, 9-11=-54, 2-10=-20 <br />Concentrated Loads (lb) <br />Vert: 3=-68(B) 9=-167(B) 20=-88(B) 5=68(B) 17=-28(8) 16=-28(B) 6=-68(B) 15=28(B) 7=68(B) 12=-88(B) 21=-68(B) 22=-68(B) 23=-68(B) 24=-68(8) 25=-68(B) <br />27=-68(B) 28=-68(B) 30=68(B) 31=-68(B) 32=-68(B) 33=-68(B) 34=68(B) 35=-28(B) 36=-28(B) 37=-28(B) 38=28(B) 39=-28(B) 40=-28(B) 41=-28(B) 42=-28(B) <br />43=-28(B) 44=-28(B) 45=28(13) 46=28(B) <br />A WARNING -verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS117P/1 quality Criteria, D38-69 and BCSI Building Component 16023 Swingley Ridge Rd <br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />