Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30850239 <br />TTH27-33 <br />T01 <br />Hip Girder <br />2 <br />Job Reference (optional) <br />burners rlrst5ource (I ampa, FL), I ampa, FL - 33Sti4, 8.b3U S NOV 19 2U22 MI I eK Industries, Inc. Mon Jun 19 12:Z9:31 ZU23 Page 1 <br />ID:tPuYCeVfQTfYt30C?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f <br />-�1-0-q 6-2-0 11-0-12 1615E 21E-0 26-6-10 M1 L-4 36-9-10 43-0-0 Q4-0-p <br />i-0-(S 612E 5-2E 5-0 10 5-0-10 5-0-10 5-0-10 5-2E 6-2-6 <br />5.00 F12 6x8 = 2x4 II 4x8 = 7x8 = <br />3 21 22 4 23 24 5 2526 27 6 <br />4x8 = 2x4 11 6x8 = <br />28 2930 7 31 32 8 33 34 9 <br />Scale = 1:73.6 <br />5x8 = 20 35 36 19 37 38 1817 39 40 16 41 42 1514 43 44 13 45 46 12 5x8 = <br />2x4 11 5x8 = 7x8 WB = 4x8 = 2x4 11 5x8 = 2x4 11 <br />2x4 I I 7x8 WB = <br />6-2-6 <br />LOADING (psf) <br />TCLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr NO <br />Code FBC2020rTP12014 <br />CSI. <br />TC 0.57 <br />BC 0.35 <br />WB 0.72 <br />Matrix-SH <br />DEFL. in <br />Vert(LL) 0.82 <br />Vert(CT) -0.96 <br />Horz(CT) 0.13 <br />floc) I/deft L/d <br />16 >625 240 <br />16 >534 180 <br />10 n/a n/a <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 531 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 "Except` TOP CHORD <br />Structural wood sheathing directly applied or 4-4-13 oc puffins. <br />3-6,6-9: 2x6 SP No.2 BOT CHORD <br />Rigid ceiling directly applied or 8-1-10 oc bracing. <br />BOT CHORD 2x6 SP M 26 <br />WEBS 2x4 SP No.3 <br />OTHERS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=-94(LC 6) <br />Max Uplift 2=-1645(LC 8). 10=1722(LC 8) <br />Max Grav 2=2532(LC 1), 10=2602(LC 1) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-5972/3778, 3-4=-8812/5811, 4-5=-8810/5809, 5-6=-11509/7662, 6-7=-11509/7662, <br />7-8=-8924/5934, 8-9=-8926/5936, 9-10=-6152/3976 <br />BOTCHORD 2-20=-3371/5458, 19-20=-3370/5475, 17-19=-7061/10896, 16-17=7061/10896, <br />15-16=-7123/10952, 13-15=-7123/10952, 12-13=-3553/5641, 10-12=-3554/5625 <br />WEBS 3-20=0/450, 3-19=2515/3773, 4-19=495/505, 5-19=-2340/1584, 5-17=0/383, <br />5-16=-539/717, 6-16=-447/498, 7-16=454/644, 7-15=0/383, 7-13=-2267/1515, <br />8-13=495/505, 9-13=-2451/3705, 9-12=0/449 <br />NOTES- (11) <br />1) 2-ply truss to be connected together with 1 Od (0.131"x3") nails as follows: <br />Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. <br />Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. <br />This Item has been <br />Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. <br />electronically signed and <br />2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to <br />sealed by Velez, Joaquin, PE <br />ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. <br />using a Digital Signature. <br />3) Unbalanced roof live loads have been considered for this design. <br />4) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />Printed copies of this <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber <br />document are not considered <br />DOL=1.60 plate grip DOL=1.60 <br />signed and sealed and the <br />5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />signature must be verified <br />to the use of this truss component. <br />6) Provide adequate drainage to prevent water ponding. <br />On any electronic Copies. <br />7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />J..gata Velez PE ne.69132 <br />8) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />ADTrk me. DRA.MiTek IBA i;L cert 6634 <br />will fit between the bottom chord and any other members. <br />16023 Svriagley Ridge Rd.Chearerfield. alo 63017 <br />9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except (jt=lb) <br />D.te: <br />2=1645, 10=1722. <br />June 20,2023 <br />A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MTek& connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must Verify the applicability of design parameters and propedy incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek} <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/f Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd <br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />