Job
<br />Truss
<br />Truss Type
<br />Qty
<br />Ply
<br />T30850242
<br />TTH2733
<br />T04
<br />Hip
<br />1
<br />1
<br />Job Reference (optional)
<br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Mon Jun 19 12:29:34 2023 Page 1
<br />ID tPuYCeVfQTfYt30C?ZvfnpzlG U H-RfC?P sB7OHg3N SgP gnL8w3u lTXbG K WrC Doi7J4zJ C?f
<br />13 648 3-13 119-10 21-6 29-7-3 35-1181 43-0-0 4"
<br />t-0-d 7-0-5 5-0-13 5-4-13 5-4-13 + 6-4-8 7-0-5 -0-
<br />5x6 =
<br />c-1f 7
<br />3x4 =
<br />5 20
<br />3x4 =
<br />3x6 — 5x6 =
<br />6 7 8
<br />Scale = 1:73.9
<br />3x8 = 18 17 " "' .1 11 13 12 3x8 =
<br />2x4 II 3x8 = 4x6
<br />3x4 = 4x6 = 3x8 = 2x4 II
<br />29-7-3 35-11-11 43-0-0
<br />LOADING (psi)
<br />TCLL 20.0
<br />TCDL 7.0
<br />BCLL 0.0
<br />BCDL 10.0
<br />SPACING- 2-0-0
<br />Plate Grip DOL 1.25
<br />Lumber DOL 1.25
<br />Rep Stress Incr YES
<br />Code FBC2020/TPI2014
<br />CSI.
<br />TC 0.82
<br />BC 0.80
<br />WB 0.76
<br />Matrix-SH
<br />DEFL.
<br />Vert(LL)
<br />Vert(CT)
<br />Horz(CT)
<br />in (loc) Udefl Lid
<br />-0.41 15-17 >999 240
<br />-0.71 15-17 >724 180
<br />0.21 10 n/a n/a
<br />PLATES GRIP
<br />MT20 244/190
<br />Weight: 219 lb FT = 20%
<br />LUMBER- BRACING -
<br />TOP CHORD 2x4 SP No.2 TOP CHORD
<br />Structural wood sheathing directly applied or 2-2-0 oc purlins.
<br />BOT CHORD 2x4 SP No.1 BOT CHORD
<br />Rigid ceiling directly applied or 4-6-12 oc bracing.
<br />WEBS 2x4 SP No.3
<br />REACTIONS. (size) 2=0-3-8, 10=0-3-8
<br />Max Horz 2=-191(LC 10)
<br />Max Uplift 2=-943(LC 12), 10=-943(LC 12)
<br />Max Grav 2=1861(LC 17), 10=1861(LC 18)
<br />FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
<br />TOP CHORD 2-3=-3963/2094, 3-4=-3216/1782, 4-5=-2947/1724, 5-7=-3388/1933, 7-8=-2947/1720,
<br />8-9=-3216/1778, 9-10=-3964/2090
<br />BOT CHORD 2-18=-1811/3722, 17-18=-181113722, 15-17=-1592/3365, 13-15=1587/3312,
<br />12-13=-1819/3579, 10-12=1819/3579
<br />WEBS 3-18=0/276, 3-17=784/507, 4-17=-405/963, 5-17=-654/357, 5-15=0/254, 7-15=0/254,
<br />7-13=-654/360,8-13=-406/963, 9-13=785/507, 9-12=0/276
<br />NOTES- (8)
<br />1) Unbalanced roof live loads have been considered for this design.
<br />2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat.
<br />ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 13-4-13, Exterior(2R)
<br />13-4-13 to 19-5-12, Interior(1) 19-5-12 to 29-7-3, Exterior(2R) 29-7-3 to 35-11-11, Interior(1) 35-11-11 to 44-0-0 zone; cantilever left
<br />and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
<br />DOL=1.60 plate grip DOL=1.60
<br />This item has been
<br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
<br />electronically signed and
<br />to the use of this truss component.
<br />sealed by Velez, Joaquin, PE
<br />4) Provide adequate drainage to prevent water ponding.
<br />5) This truss has been designed for
<br />using a Digital Signature.
<br />a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
<br />6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
<br />Printed copies of this
<br />will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
<br />document are not Considered
<br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
<br />signed and sealed and the
<br />2=943, 10=943.
<br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any
<br />signature must be verified
<br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
<br />on any electronic copies.
<br />Jeegnia Velez PE Ne.68182
<br />Nilek Inc. DBA 3BTek USA FL Cert6634
<br />16023 Sainglep Ridge Rd.
<br />Chesterfield, MO 63017
<br />Date:
<br />June 20,2023
<br />A WARNING - verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
<br />--
<br />Design valid for use only, with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
<br />a truss system. Before use, the building designer must verify the applicability, of design parameters and properly incorporate this design into the overall
<br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek°
<br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
<br />fabrication, storage, detivery, erection and bracing of trusses and truss systems, see ANSUMI Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd
<br />Safely Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017
<br />
|