Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30641482 <br />TTH119-125 <br />T05A <br />Hip <br />1 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:13 2023 Page 1 <br />I D: tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?P s B7OHg3N Sg Pqn L8w3u ITXbG KWrC Doi7J4zJ C?f <br />-1-0-Q 8-4-4 15-9-10 21-6-0 27-2-6 34-7-12 43-0-0 <br />8-4� 7-5-5 5-8-6 5-8-6 7-5-5 84-4 <br />Scale = 1:75.1 <br />5.00 12 5x8 = 2x4 II 5x8 = <br />5 17 6 18 19 20 7 <br />3x8 = 15 14 ZZ 13 Ld 12 11 3x8 = <br />2x4 II 5x6 = 3x8 = 5x6 = <br />2x4 11 <br />IQ. <br />LOADING (psf) <br />TOLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr YES <br />Code FBC2020/TPI2014 <br />CSI. <br />TC 1.00 <br />BC 0.90 <br />WB 0.36 <br />Matrix-SH <br />DEFL. in (loc) I/deft L/d <br />Vert(LL) 0.36 13 >999 240 <br />Vert(CT) -0.56 12-13 >918 180 <br />Horz(CT) 0.20 10 n/a n/a <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 220 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied. <br />1-4,8-10: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-4-12 oc bracing. <br />BOT CHORD 2x4 SP No.1 *Except* WEBS 1 Row at midpt 3-14, <br />9-12 <br />12-14: 2x4 SP No.2 <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=221(LC 11) <br />Max Uplift 2=-944(LC 12), 110=857(LC 12) <br />Max Grav 2=1861(LC 17), 10=1807(LC 18) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3889/2054, 3-5=-2974/1694, 5-6=2884/1753, 6-7=-2884/1753, 7-9=-2975/1694, <br />9-10=-3884/2055 <br />BOT CHORD 2-15=-179713663, 14-15=-1797/3663, 13-14=-1261/2779, 12-13=-1249/2675, <br />11-12=-1791/3514, 10-11=-1791/3514 <br />WEBS 3-15=0/345, 3-14=-980/593, 5-14=209/669, 5-13=-199/448, 6-13=-337/306, <br />7-13=-196/447, 7-12=-212/672, 9-12=989/600, 9-11=0/346 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 15-9-10, Exterior(2R) <br />15-9-10 to 21-10-9, Interior(1) 21-10-9 to 27-2-6, Exterior(2R) 27-2-6 to 33-3-6, Interior(1) 33-3-6 to 42-10-4 zone; cantilever left and <br />This item has been <br />right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 <br />electronically signed and <br />plate grip DOL=1.60 <br />sealed by Velez, Joaquin, PE <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />using a Digital Signature. <br />to the use of this truss component. <br />4) Provide adequate drainage to prevent water ponding. <br />Printed copies Of this <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />document are not Considered <br />6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />signed and sealed and the <br />will fit between the bottom chord and any other members, with BCDL = 10.Opsf. <br />signature <br />nature must be verified <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 944 lb uplift at joint 2 and 857 lb uplift at <br />joint 10. <br />on any electronic copies. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />Jeagtda Velez PE tio.68182 <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />MiTek Luc. DBA 311Tek USA rL CeR 6634 <br />16023 Swfagtee Midge Rd. <br />Cheslerfletd. M0 63017 <br />Date: <br />May 25,2023 <br />A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSi Building Component 16023 Swingley Ridge Rd <br />Sarety/nformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />