Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30641483 <br />TTH119-125 <br />T06 <br />Hip <br />1 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:14 2023 Page 1 <br />ID: tP uYCeVfQTfYt30C?ZvfnpzlG U H-RfC?P5B70H g3NSgPgnL8w3u ITXbGK WrC Doi7J4zJC?f <br />1 0 Q 6 6 0 12 4-3 18-2-6 24-9-10 30-7-13 36-6-0 43-0-0 44-0-p <br />6E-0 5-10-3 5-10-3 6-7-3 5-10-3 5-10-3 6-6-0 <br />Sx6 = <br />5.00 12 <br />6 20 <br />5x8 = <br />721 <br />Scale = 1:75.2 <br />3x8 = o — — a 16 " 15 - — `r - 3x8 = <br />3x4 = 4x6 = 3x8 = <br />LOADING (psf) <br />SPACING- <br />2-0-0 <br />CSI. <br />TCLL <br />20.0 <br />Plate Grip DOL <br />1.25 <br />TC 0.84 <br />TCDL <br />7.0 <br />Lumber DOL <br />1.25 <br />BC 0.98 <br />BCLL <br />0.0 * <br />Rep Stress Incr <br />YES <br />WB 0.99 <br />BCDL <br />10.0 <br />Code FBC2020/TPI2014 <br />Matrix-SH <br />LUMBER - <br />TOP CHORD <br />2x4 SP No.2 <br />BOT CHORD <br />2x4 SP No.1 *Except* <br />14-17: 2x4 SP No.2 <br />WEBS <br />2x4 SP No.3 <br />REACTIONS. <br />(size) 2=0-3-8, 11=0-3-8 <br />Max Horz 2=-254(LC 10) <br />Max Uplift 2=-943(LC 12), 11=943(LC 12) <br />Max Grav 2=1872(LC 17), 11=1876(LC 18) <br />3x4 = 4x6 <br />3x4 = <br />DEFL. in (loc) I/defl L/d PLATES GRIP <br />Vert(LL) -0.40 13-15 >999 240 MT20 244/190 <br />Vert(CT) -0.70 13-15 >733 180 <br />Horz(CT) 0.20 11 n/a n/a <br />Weight: 223 lb FT = 20% <br />BRACING - <br />TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puffins. <br />BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing, Except: <br />5-8-0 oc bracing: 15-16. <br />WEBS 1 Row at midpt 7-16 <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3934/2082, 3-5=-3693/1963, 5-6=2723/1603, 6-7=2481/1552, 7-8=2733/1603, <br />8-1 0=-3702/1963, 10-11 =-3943/2082 <br />BOT CHORD 2-18=-1800/3760, 16-18=-1470/3172, 15-16=-1093/2484, 13-15=1483/3010, <br />11-13=-1813/3578 <br />WEBS 3-18=-333/332, 5-18=-192/687, 5-16=820/522, 6-16=-296/753, 7-15=-297/836, <br />8-15=-820/522, 8-13=-192/687, 10-13=333/332 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vuk=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 18-2-6, Exterior(2R) <br />18-2-6 to 24-3-6, Interior(1) 24-3-6 to 24-9-10, Exterior(2R) 24-9-10 to 30-7-13, Interior(1) 30-7-13 to 44-0-0 zone; cantilever left and <br />right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 <br />plate grip DOL=1.60 <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />4) Provide adequate drainage to prevent water ponding. <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members, with BCDL = 10.Opsf. <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at <br />joint 11. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />I¢ <br />This item has been <br />electronically signed and <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />Jouquiu Velez PE No.68182 <br />iDTek 1— DBA.MiTek USA FI. Cert 6634 <br />1602.i Svrludep Ridge Rd. <br />Chesterfield. MO 63017 <br />D.tec <br />May 25,2023 <br />A WARNING - Veny design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPIf Queft Criteria, DSB•89 and SCSI Building Component 16023 Swingley Ridge Rd <br />Safetylnformstion available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />