Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30641898 <br />TTH115-118 <br />T02 <br />Hip <br />2 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:27:47 2023 Page 1 <br />ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f <br />-1-0 5-1-7 8-7-3 15-1-10 21-6 0 27-10-6 34.4-13 37-10-9 431-0 -0- <br />-0 5-1-7 3-5-12 6b-7 6-4-6 6-4-6 6-C 7 3-5-12-0- <br />Scale = 1:73.6 <br />3x4 = <br />5x6 = UIS = <br />5.00 12 3x4 = 3x4 = 5x6 = <br />4 21 522 23 6 7 24 825 26 9 <br />M <br />2 <br />I4 <br />0 <br />5x8 = 18 17 16 15 14 13 5x8 = <br />4x8 = 6x8 = 4x4 = 4x4 = 6x8 = 4x8 = <br />8-7-3 17-7-10 25-4-6 <br />34-4-13 43-0-0 <br />8-7-3 9-0-7 7-8-12 <br />9-0-7 8-7-3 <br />Plate Offsets (X,Y)— [2:0-4-0,Edge], [4:0-3-0,0-2-4] [7:0-3-0,Edge], [9:0-3-0,0-2-4] [11:0-4-0,Edge] <br />LOADING (psf) <br />SPACING- 2-0-0 <br />CSI. <br />DEFL. <br />in (loc) I/defl Ud <br />PLATES GRIP <br />TCLL 20.0 <br />Plate Grip DOL 1.25 <br />TC 0.77 <br />Vert(LL) <br />0.63 15-16 >811 240 <br />MT20 244/190 <br />TCDL 7.0 <br />Lumber DOL 1.25 <br />BC 0.82 <br />Vert(CT) -0.87 15-16 >591 180 <br />BCLL 0.0 <br />Rep Stress Incr YES <br />WB 0.47 <br />Horz(CT) <br />0.18 11 n/a n/a <br />BCDL 10.0 <br />Code FBC2020/TP12014 <br />Matrix-SH <br />Weight: 239 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 TOP CHORD <br />Structural wood sheathing directly applied or 2-2-0 oc purlins. <br />BOT CHORD 2x6 SP No.2 BOT CHORD <br />Rigid ceiling directly applied or 4-6-14 oc bracing. <br />WEBS 2x4 SP No.3 WEBS <br />1 Row at midpt 5-18, 8-13 <br />REACTIONS. (size) 2=0-3-8, 11=0-3-8 <br />Max Horz 2=127(LC 11) <br />Max Uplift 2=-943(LC 12), 11=-943(LC 12) <br />Max Grav 2=1642(LC 1), 11=1642(LC 1) <br />FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3606/2164, 3-4=-3350/1984, 4-5=3101/1890, 5-6=4582/2725, 6-8=4582/2725, <br />8-9=-3101/1890, 9-10=-3350/1984, 10-11=-3606/2164 <br />BOT CHORD 2-18=-1889/3276, 16-18=-2429/4354, 15-16=-2620/4761, 13-15=-2412/4354, <br />11-13=-1906/3276 <br />WEBS 3-18=-266/323, 4-18=-519/1010, 5-18=-1504/893, 5-16=140/447, 6-16=-291/242, <br />6-15=-291/242, 8-15=-140/447, 8-13=-1504/893, 9-13=-519/1010, 10-13=-266/323 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 8-7-3, Exterior(2R) <br />8-7-3 to 14-8-3, Interior(1) 14-8-3 to 34-4-13, Exterior(2R) 34-4-13 to 40-5-12, Interior(1) 40-5-12 to 44-0-0 zone; cantilever left and <br />right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 <br />plate grip DOL=1.60 <br />This item has been <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />electronically signed and <br />to the use of this truss component. <br />sealed by Velez, Joaquin, PE <br />4) Provide adequate drainage to prevent water ponding. <br />using a Digital Signature. <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />Printed copies of this <br />will fit between the bottom chord and any other members. <br />document are not considered <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) <br />signed and sealed and the <br />2=943, 11=943. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />signature must be verified <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code" <br />on any electronic copies. <br />Joagnin Velez PE \o.68182 <br />VBiek Inc. DBA NU Tek USA FL Ccn 6634 <br />16023 Swingtey Ridge Rd. <br />Chesferfieid.310 63017 <br />Me: <br />May 25,2023 <br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. <br />-- <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall <br />building tlesign. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M ]Tek <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPIf Quality Criteria, DSB49 and SCSI Building Component 16023 Swingley Ridge Rd <br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />