Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30641899 <br />TTH115-118 <br />T03 <br />Hip <br />2 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:27:49 2023 Page 1 <br />I D: tP uYCeVfQTfYt3OC?Zvfn pzlG U H-RfC?P sB7OH q3N SgPgn L8w3u ITXbG K WrC Do i7J 4zJC?f <br />�1-0-Q 6-6-5 11-0-0 18-0-9 24-11-7 32-0-0 365-11 43-0-0 4i4-0-p <br />6 6 5 4-5-11 7-0-9 6-10-13 7 0 9 4-5 11 6 6 5 <br />5.00 F12 <br />5x8 = <br />421 <br />2x4 II <br />22 5 23 <br />5x8 = <br />24 6 25 <br />5x6 = <br />726 <br />Scale = 1:73.7 <br />3x6 15� 18 17 16 15 14 13 12 11 3x6 <br />2x4 11 3x4 = <br />LOADING (psf) <br />SPACING- <br />2-0-0 <br />TCLL <br />20.0 <br />Plate Grip DOL <br />1.25 <br />TCDL <br />7.0 <br />Lumber DOL <br />1.25 <br />BCLL <br />0.0 <br />Rep Stress Incr <br />YES <br />BCDL <br />10.0 <br />Code FBC2020/TP12014 <br />LUMBER - <br />TOP CHORD <br />2x4 SP No.2 'Except' <br />4-6: 2x4 SP No.1 <br />BOT CHORD <br />2x4 SP No.2 <br />WEBS <br />2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 9=0-3-8 <br />Max Horz 2=-159(LC 10) <br />Max Uplift 2=-943(LC 12), 9=943(LC 12) <br />Max Grav 2=1642(LC 1), 9=1642(LC 1) <br />4x6 = 3x10 = <br />2x4 11 5x6 = <br />3x8 = <br />2x4 II <br />43-0-0 <br />CSI. <br />DEFL. <br />in (loc) I/clef! Ud <br />PLATES GRIP <br />TC 0.87 <br />Vert(LL) <br />0.5214-15 >988 240 <br />MT20 244/190 <br />BC 0.94 <br />Vert(CT)-0.7314-15 >699 180 <br />WB 0.75 <br />Horz(CT) <br />0.23 9 n/a n/a <br />Matrix-SH <br />Weight: 218 lb FT = 20% <br />BRACING - <br />TOP CHORD <br />Structural wood sheathing directly applied. <br />BOT CHORD <br />Rigid ceiling directly applied or 2-2-0 oc bracing. <br />WEBS <br />1 Row at midpt 6-15, 6-12 <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3513/2077, 3-4=-3065/1877, 4-5=-3608/2259, 5-6=-3608/2259, 6-7=2810/1792, <br />7-8=-3066/1877, 8-9=-3512/2077 <br />BOT CHORD 2-18=-1794/3166, 17-18=-1794/3166, 15-17=-1479/2792, 14-15=1949/3605, <br />12-14=-1949/3603, 11-12=1806/3165, 9-11=-1806/3165 <br />WEBS 3-17=-476/379, 4-17=-161/394, 4-15=577/1078, 5-15=398/374, 6-14=0/281, <br />6-12=-1058/570, 7-12=-462/882, 8-112=475/379 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 11-0-0, Exterior(2R) <br />11-0-0 to 17-1-0, Interior(1) 17-1-0 to 32-0-0, Exterior(2R) 32-0-0 to 38-1-0, Interior(1) 38-1-0 to 44-0-0 zone; cantilever left and right <br />exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate <br />grip DOL=1.60 <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />4) Provide adequate drainage to prevent water ponding. <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) <br />2=943, 9=943. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />This item has been <br />electronically signed and <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />Joegrde VA- PE \0.68182 <br />VBTek Iue. DBA 4BTek 1'SA FL Cert6634 <br />16023 Svdegtey Ridge Rd. <br />Chesterfield.110 63017 <br />Date: <br />May 25,2023 <br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, we ANSI?P/i Quality Crlterls, DSB-89 and SCSI Building Component 16023 Svingley Ridge Rd <br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />