Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30641900 <br />TTH115-118 <br />T04 <br />Hip <br />1 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:27:51 2023 Page 1 <br />ID:tPuYCeVfQTfYt30C?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f <br />1-0-0 0-7-5 13- 3 18-9-10 24-2-6 29-7-3 35-11-11 43-0-0 44-0-Q <br />7-0-5 6-4-8 5-4-13 5-4-13 5-4-13 <br />5x6 = <br />3x4 = <br />5 20 <br />3x4 = <br />3x6 = <br />6 7 <br />5x6 = <br />8 <br />Scale = 1:73.9 <br />3x8 = 18 17 -lo « <s 10 Z4 Zo 14 13 12 3x8 = <br />2x4 II 3x8 = 4x6 <br />3x4 = <br />4x6 = 3x8 = <br />2x4 11 <br />1 7-0-5 13-4-13 21-6-0 29-7-3 35-11-11 1 _ 43-0-0 1 <br />7-0-5 6 4 8 8-1-3 8-1-3 6 4 8 7-0-5 <br />Plate Offsets (X Y)— [2:0-4-2 0-1-8] [4:0-3-0 0-2-4] [8:0-3-0 0-2-4],[10:0-4-2 0-1-81 <br />LOADING (psf) <br />SPACING- 2-0-0 <br />CSI. <br />DEFL. <br />in (loc) I/deft Ud <br />PLATES GRIP <br />TCLL 20.0 <br />Plate Grip DOL 1.25 <br />TC 0.82 <br />Vert(LL) <br />-0.41 15-17 >999 240 <br />MT20 244/190 <br />TCDL 7.0 <br />Lumber DOL 1.25 <br />BC 0.80 <br />Vert(CT) <br />-0.71 15-17 >724 180 <br />BCLL 0.0 <br />Rep Stress Incr YES <br />WB 0.76 <br />Horz(CT) <br />0.21 10 n/a n/a <br />BCDL 10.0 <br />Code FBC2020/TPI2014 <br />Matrix-SH <br />Weight: 219 lb FT = 20% <br />LUMBER- <br />BRACING - <br />TOP CHORD 2x4 SP No.2 <br />TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. <br />BOT CHORD 2x4 SP No.1 <br />BOT CHORD Rigid ceiling directly applied or 4-6-12 oc bracing. <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=-191(LC 10) <br />Max Uplift 2=-943(LC 12), 10=-943(LC 12) <br />Max Grav 2=1861(LC 17), 10=1861(LC 18) <br />FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3963/2094, 3-4=-3216/1782, 4-5=-2947/1724, 5-7=-3388/1933, 7-8=-2947/1720, <br />8-9=-3216/1778, 9-10=-3964/2090 <br />BOT CHORD 2-18=-1811/3722, 17-18=-1811/3722, 15-17=-1592/3365, 13-15=1587/3312, <br />12-13=-1819/3579,10-12=1819/3579 <br />WEBS 3-18=0/276, 3-17=-784/507, 4-17=-405/963, 5-17=-654/357, 5-15=0/254, 7-15=0/254, <br />7-13=-654/360, 8-13=-406/963, 9-13=-785/507, 9-12=0/276 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 13-4-13, Exterior(2R) <br />13-4-13 to 19-5-12, Interior(1) 19-5-12 to 29-7-3, Exterior(2R) 29-7-3 to 35-11-11, Interior(1) 35-11-11 to 44-0-0 zone; cantilever left <br />and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber <br />DOL=1.60 plate grip DOL=1.60 <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />4) Provide adequate drainage to prevent water ponding. <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members, with BCDL = 10.Opsf. <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) <br />2=943,10=943. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />This item has been <br />electronically signed and <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />Joagnin Velez PE N..68182 <br />MiTtli loc. DBA MITek USA FL Cert 6634 <br />16023 Sstrir y Ridge Rd. <br />Chesterfield, 110 63017 <br />Date: <br />May 25,2023 <br />A WARNING - Ved(y design parameters and READ NOTES ON THIS AND INCLUDED MI TEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not ' <br />a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M�Tek <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd <br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />