Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T31961914 <br />TTH99-106 <br />T03 <br />Hip <br />2 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:24 2023 Page 1 <br />ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f <br />-i1-0-p 6-6-5 11-0-0 18-0-9 24-11-7 32-0-0 36-5-11 _ 43-0-0 <br />-0- 6-6-5 4-5-11 7-0-9 6-10-13 7-0-9 4-5-11 6-6-5 -0- <br />5.00 r12 <br />5x8 = <br />421 <br />2x4 II <br />22 5 23 <br />5x8 = <br />24 6 25 <br />5x6 = <br />726 <br />Scale = 1,73.7 <br />3x6 - 18 17 16 15 14 13 12 11 3x6 <br />2x4 11 3x4 = <br />7-0-9 <br />4x6 = 3x10 = <br />2x4 11 5x6 = <br />US = 2x4 11 <br />36-5-11 43-0-0 <br />4 <br />0 <br />I� <br />LOADING (psf) <br />SPACING- 2-0-0 <br />CSI. <br />DEFL. in (loc) I/deft Ud <br />PLATES GRIP <br />TCLL 20.0 <br />Plate Grip DOL 1.25 <br />TC 0.87 <br />Vert(LL) 0.52 14-15 >988 240 <br />MT20 244/190 <br />TCDL 7.0 <br />Lumber DOL 1.25 <br />BC 0.94 <br />Vert(CT) -0.73 14-15 >699 180 <br />BCLL 0.0 <br />Rep Stress Incr YES <br />WB 0.75 <br />Horz(CT) 0.23 9 n/a n/a <br />BCDL 10.0 <br />Code FBC2020rrPI2014 <br />Matrix-SH <br />Weight: 218 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 "Except* TOP CHORD Structural wood sheathing directly applied. <br />4-6: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. <br />BOT CHORD 2x4 SP No.2 WEBS 1 Row at midpt <br />6-15, 6-12 <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 9=0-3-8 <br />Max Horz 2=159(LC11) <br />Max Uplift 2=-943(LC 12), 9=-943(LC 12) <br />Max Grav 2=1642(LC 1), 9=1642(LC 1) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3513/2077, 3-4=-3065/1877, 4-5=-3608/2259, 5-6=3608/2259, 6-7=2810/1792, <br />7-8=-3066/1877,8-9=-3512/2077 <br />BOT CHORD 2-18=-1794/3166, 17-18=-1794/3166, 15-17=-1479/2792, 14-15=1949/3605, <br />12-14=-1949/3603, 11-12=1806/3165, 9-11=-1806/3165 <br />WEBS 3-17=-476/379, 4-17=-161/394, 4-15=-577/1078, 5-15=-398/374, 6-14=0/281, <br />6-12=-1058/570, 7-12=-462/882, 8-12=-475/379 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 11-0-0, Exterior(2R) <br />11-0-0 to 17-1-0, Interior(1) 17-1-0 to 32-0-0, Exterior(2R) 32-0-0 to 38-1-0, Interior(1) 38-1-0 to 44-0.0 zone; cantilever left and right <br />exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate <br />This item has been <br />grip DOL=1.60 <br />electronically signed and <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />sealed by Velez, Joaquin, PE <br />to the use of this truss component. <br />using a Digital Signature. <br />4) Provide adequate drainage to prevent water ponding. <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />Printed Copies Of this <br />6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />document are not considered <br />will fit between the bottom chord and any other members. <br />signed and sealed and the <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at <br />signature must be verified <br />g <br />joint 9. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />on any electronic copies. <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />2oa4akt ael- PE No.6sis2 <br />%117ek IUc.DBA36Tek CSA ELCe,T6WU <br />16023 SRmglov Ridge Rd. <br />CkesterfleW. 310 6301? <br />Date. <br />October 27,2023 <br />A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 1/212023 BEFORE USE. <br />Design valid for use only with MUM connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />MiTek' <br />a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general gguidance regarding Me <br />fabrication, delivery, bracing trusses and truss ANSViP11 Quality Criteria and MISS-22 available from Truss Plate Institute (www.tpinst.org) <br />16023 Swingley Ridge Rd. <br />storage, erection and of systems, see <br />and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcsoomponents.com) <br />Chesterfield, MO 63017 <br />314.434.1200 / MTek-US.com <br />