Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T31961915 <br />TTH99-106 <br />T04 <br />Hip <br />1 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:26 2023 Page 1 <br />I D:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC.7f <br />-�1-0-Q 7-0-5 13-4-13 18-9-10 24-2-6 29-7-3 3%11-11 43-0-0 4,4-0-p <br />-0- 7-0-5 6-4-8 5-4-13 5-4-13 5-4-13 64-8 + 7-0-5 -0- <br />5x6 = <br />s nnF1 oT <br />3x4 = <br />3x4 = U6 = 5x6 = <br />5 20 6 7 8 <br />Scale = 1,73.9 <br />6 <br />I� <br />3x8 = 18 17 .o " `° lu `� " - 13 12 3x8 = <br />2x4 11 3x8 = 4x6 = 3x4 = 4x6 = 3x8 = 2x4 II <br />LOADING (psf) <br />TCLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr YES <br />Code FBC2020ITP12014 <br />CSI. <br />TC 0.82 <br />BC 0.80 <br />WB 0.76 <br />Matrix-SH <br />DEFL. <br />Vert(LL) <br />Vert(CT) <br />Horz(CT) <br />in (loc) Vdefl Ud <br />-0.41 15-17 >999 240 <br />-0.71 15-17 >724 180 <br />0.21 10 n/a n/a <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 219 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. <br />BOT CHORD 2x4 SP No.1 BOT CHORD <br />Rigid ceiling directly applied or 4-6-12 oc bracing. <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=-191(LC 10) <br />Max Uplift 2=-943(LC 12), 10=943(1_13 12) <br />Max Grav 2=1861(LC 17), 10=1861(LC 18) <br />FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3963/2094, 3-4=-3216/1782, 4-5=2947/1724, 5-7=3388/1933, 7-8=2947/1720, <br />8-9=-3216/1778,9-10=-3964/2090 <br />BOT CHORD 2-18=-1811/3722, 17-18=-1811/3722, 15-17=-1592/3365, 13-15=1587/3312, <br />12-13=-1819/3579, 10-12=1819/3579 <br />WEBS 3-18=0/276, 3-17=784/507, 4-17=-405/963, 5-17=-654/357, 5-15=0/254, 7-15=0/254, <br />7-13=-654/360, 8-13=-406/963, 9-13=785/507, 9-12=0/276 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vutt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 13-4-13, Exterior(2R) <br />13-4-13 to 195-12, Interior(1) 19-5-12 to 29-7-3, Exterior(21R) 29-7-3 to 35-11-11, Interior(1) 35-11-11 to 44-0-0 zone; cantilever left <br />and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber <br />DOL=1.60 plate grip DOL=1.60 <br />This item has been <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />electronically signed and <br />to the use of this truss component. <br />sealed by Velez, Joaquin, PE <br />4) Provide adequate drainage to prevent water ponding. <br />using a Digital Signature. <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />Printed copies of this <br />will fit between the bottom chord and any other members, with BCOL = 10.Opsf. <br />document are not Considered <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at <br />signed and sealed and the <br />joint 10. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />signature must be verified <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />on any electronic copies. <br />3-itnin Velez PE \0.68182 <br />\lliek Wc. DBA 381-ek C�SA FL Cert6634 <br />16023 Sritigle, Ridge Rd. <br />Cbevlerfield. \t0 630I- <br />Uarr: <br />October 27,2023 <br />A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/212023 BEFORE USE. i �� �:P <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see AINJSIrrPI1 Quality Criteria and SB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 <br />and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponenls.com) 314.434.1200 / MiTek-US.com <br />