<br />T31406290
<br />TTH47-55
<br />T01
<br />Hip Girder
<br />2
<br />n
<br />L
<br />Job Reference (optional)
<br />buitaers F1fst,0Urce (I ampa, t-L), I ampa, I-L - 3Jbb4, C.bJU s Jul z6 zuz3 mi I eK industries, Inc. I nU Aug 24 12:6U:4b ZUZ3 rage 1
<br />I D: tP uYCeVfQTfYt30C?ZvfnpzlG U H-RfC?PsB7OH g3NSgPgn L8w3ulTXbGKWrC DOi7J4ZJC?f
<br />-1-0-p 6-2-6 111 12 16-5-6 21-6-0 26-6-10 31-7-4 36-9-10 43-0 0 4,4-0-Q
<br />0 6-2 6 5-2 6 5-0-10 5-0-10 5-0-10 5-0-10 5-2 6 6-2 6 0
<br />0
<br />5.00 12 6x8 = 2x4 II 4x8 = 7x8 = 4x8 =
<br />3 21 22 4 23 24 5 2526 27 6 28 2930 7 31
<br />2x4 II 6x8 =
<br />32 8 33 34 9
<br />Scale = 1:73.6
<br />5x8 = 20 35 36 19 37 38 1817 39 40 16 41 42 1514 43 44 13 45 46 12 5x8 =
<br />2x4 11 5x8 = 7x8 WB = 4x8 = 2x4 11 5x8 = 2x4 11
<br />2x4 17x8 WB =
<br />LOADING (psf)
<br />TCLL 20.0
<br />TCDL 7.0
<br />BCLL 0.0
<br />BCDL 10.0
<br />SPACING- 2-0-0
<br />Plate Grip DOL 1.25
<br />Lumber DOL 1.25
<br />Rep Stress Incr NO
<br />Code FBC2020ITP12014
<br />CSI.
<br />TC 0.57
<br />BC 0.35
<br />WB 0.72
<br />Matrix-SH
<br />DEFL. in
<br />Vert(LL) 0.82
<br />Vert(CT) -0.96
<br />Horz(CT) 0.13
<br />(loc) I/defl L/d
<br />16 >625 240
<br />16 >534 180
<br />10 n/a n/a
<br />PLATES GRIP
<br />MT20 244/190
<br />Weight: 531 lb FT = 20%
<br />LUMBER- BRACING -
<br />TOP CHORD 2x4 SP No.2 `Except` TOP CHORD
<br />Structural wood sheathing directly applied or 4-4-13 oc purlins.
<br />3-6,6.9: 2x6 SP No.2 BOT CHORD
<br />Rigid ceiling directly applied or 8-1-10 oc bracing.
<br />BOT CHORD 2x6 SP M 26
<br />WEBS 2x4 SP No.3
<br />OTHERS 2x4 SP No.3
<br />REACTIONS. (size) 2=0-3-8, 10=0-3-8
<br />Max Horz 2=94(LC 23)
<br />Max Uplift 2=1645(LC 8), 10=1722(LC 8)
<br />Max Grav 2=2532(LC 1), 10=2602(LC 1)
<br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
<br />TOP CHORD 2-3=-5972/3778, 3-4=-8812/5811, 4-5=8810/5809, 5-6=11509/7662, 6-7=11509/7662,
<br />7-8=-8924/5934, 8-9=-8926/5936, 9-10=-6152/3976
<br />BOT CHORD 2-20=-3371/5458, 19-20=-3370/5475, 17-19=-7060/10896, 16-17=7060/10896,
<br />15-16=-7123/10952, 13-15=7123/10952, 12-13=3553/5641, 10-12=3554/5625
<br />WEBS 3-20=0/450, 3-19=2515/3773, 4-19=-495/505, 5-19=2340/1584, 5-17=0/383,
<br />5-16=-539/717, 6-16=-447/498, 7-16=454/644, 7-15=01383, 7-13=-2267/1515,
<br />8-13=-495/505, 9-13=-2451/3705, 9-12=0/449
<br />NOTES- (11)
<br />1) 2-ply truss to be connected together with 1 Od (0.131 "x3") nails as follows:
<br />Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
<br />Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
<br />This Item has been
<br />Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
<br />electronically signed and
<br />2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
<br />sealed by Velez, Joaquin, PE
<br />ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
<br />using a Digital Signature.
<br />3) Unbalanced roof live loads have been considered for this design.
<br />4) Wind: ASCE 7-16; VuIt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat.
<br />Printed copies of this
<br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
<br />document are not considered
<br />DOL=1.60 plate grip DOL=1.60
<br />signed and sealed and the
<br />5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
<br />signature must be verified
<br />to the use of this truss component.
<br />6) Provide adequate drainage to prevent water ponding.
<br />On any electronic copies.
<br />7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
<br />J..gnin velea PE N..69182
<br />8) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
<br />Jlirek Luc. DBA ailTek USA FL Cert6634
<br />will fit between the bottom chord and any other members.
<br />16023 Swingley Ridge Rd.
<br />Ckesterfield, \70 63017
<br />9 Provide mechanical connection b others of truss to bearing late capable of withstanding 1645 lb uplift at joint 2 and 1722 lb uplift
<br />(Y ) 9 P P 9 P 1 p
<br />D.te:
<br />at joint 10.
<br />August 25,2023
<br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1/2/2023 BEFORE USE.
<br />Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
<br />MiTekg
<br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
<br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
<br />is always required for stability and to prevent collapse with possible personal injury and pproppertyy damage. For general guidance regarding the
<br />guidance
<br />16023 Swingley Ridge Rd.
<br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSXt1 Quality Crtterla and available from Truss Plate Institute (wwwApinst.org)
<br />and BCSI Building Component Safety information available from the Structural Building Component Association (www.sbcscomponents.com)
<br />Chesterfield, MO 63017
<br />314.434.12001 MTek-US.com