Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T31406290 <br />TTH47-55 <br />T01 <br />Hip Girder <br />2 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Jul 28 2023 MITek Industries, Inc. Thu Aug 24 12:30:46 2023 Page 2 <br />I D: tPuYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?PSB70H q3N SgPgnL8w3u ITXbGKWrC Doi7J4zJC?f <br />NOTES- (11) <br />10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 124 lb down and 158 lb up at 6-2-6, 125 lb down and 153 lb up at <br />8-3-2, 125 lb down and 153 lb up at 10-3-2, 124 lb down and 153 lb up at 12-3-2, 124 lb down and 153 lb up at 14-3-2, 124 lb down and 153 lb up at 16-3-2, 124 lb <br />down and 153 lb up at 18-3-2, 124 lb down and 153 lb up at 20-3-2, 124 lb down and 153 lb up at 21-6-0, 124 lb down and 153 lb up at 22-8-14, 124 lb down and 153 lb <br />up at 24-8-14, 124 lb down and 153 lb up at 26-8-14, 124 lb down and 153 lb up at 28-8-14, 124 lb down and 153 lb up at 30-8-14, 125 lb down and 153 lb up at <br />32-8-14, and 125 lb down and 153 lb up at 34-8-14, and 225 lb down and 372 lb up at 36-9-10 on top chord, and 141 lb down at 6-2-6, 56 lb down at 8-3-2, 56 lb down <br />at 10-3-2, 56 lb down at 12-3-2, 56 lb down at 14-3-2, 56 lb down at 16-3-2, 56 lb down at 18-3-2, 56 lb down at 20-3-2, 56 lb down at 21-6-0, 56 lb down at 22-8-14, <br />56 lb down at 24-8-14, 56 lb down at 26-8-14, 56 lb down at 28-8-14, 56 lb down at 30-8-14, 56 lb down at 32-8-14, and 56 lb down at 34-8-14, and 141 lb down at <br />36-8-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. <br />11) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of <br />the building designer per ANSI TPI 1 as referenced by the building code." <br />LOAD CASE(S) Standard <br />1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 <br />Uniform Loads (plf) <br />Vert: 1-3=54, 3-9=54, 9-11=54, 2-10=-20 <br />Concentrated Loads (lb) <br />Vert: 3=-68(B) 9=-167(B) 20=-88(B) 5=-68(B) 17=-28(B) 16=-28(B) 6=-68(B) 15=28(B) 7=68(B) 12=-88(B) 21=-68(B) 22=-68(B) 23=-68(B) 24=-68(B) 25=-68(B) <br />27=-68(B) 28=-68(B) 30= 68(B) 31=68(B) 32=-68(B) 33=-68(B) 34=-68(B) 35=-28(B) 36=-28(B) 37=-28(B) 38=28(B) 39=28(B) 40=-28(B) 41=-28(B) 42=-28(B) <br />43=-28(B) 44=-28(B) 45=-28(B) 46=-28(B) <br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 11212023 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />MiTeV <br />a truss system. Before use, the building designer must verity the applicability of design parameters and property incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and proper damage. For general guidance regarding the <br />A SIfTP 1 Qualg Criteria DSB-22 from Truss Plate Institute <br />16023 Swingley Ridge Rd. <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see and evadable (www.tpinst.org) <br />and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) <br />Chesterfield, MO 63017 <br />314.434.1200 / MTek-US.com <br />