Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30256128 <br />TTH23-26 <br />T02 <br />Hip <br />2 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s,Nov 19 2022 MiTek Industries, Inc. Thu Apr 6 08:43:30 2023 Page 1 <br />ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-w9CIBV15xl6551WiGNgSoUWAXxKvx1 s49YCvwpzTUjx <br />-1-0-Q 5-1-7 8-7-3 15-1-10 21-6-0 27-10-6 34-0-13 37-10-9 43-0-0 <br />-0- 5-1-7 3-5-12 6-6-7 6�Fi 6-4-6 617 3-5-12 5-1-7 -0- <br />3x4 = <br />5x6 = 4x6 = <br />5.00 12 3x4 = 3x4 = 5x6 = <br />4 21 522 23 6 7 24 825 26 9 <br />0 <br />Scale =1:74.0 <br />5x8 = 18 17 16 15 14 13 5x8 = <br />4x8 = 6x8 = 4x4 = 4x4 = 6x8 = 4x8 = <br />8-7-3 17-7-10 25-" 34-4-13 i 43-0-0 <br />8-7-3 9-0-7 7-8-12 9-0-7 8-7-3 <br />LOADING (psf) <br />SPACING- <br />2-0-0 <br />TCLL <br />20.0 <br />Plate Grip DOL <br />1.25 <br />TCDL <br />7.0 <br />Lumber DOL <br />1.25 <br />BCLL <br />0.0 <br />Rep Stress Incr <br />YES <br />BCDL <br />10.0 <br />Code FBC2020/TPI2014 <br />LUMBER - <br />TOP CHORD 2x4 SP No.2 <br />BOT CHORD 2x6 SP No.2 <br />WEBS 2x4 SP No.3 <br />CSI. <br />DEFL. <br />in (loc) <br />I/deft <br />L/d <br />TIC 0.77 <br />Vert(LL) <br />0.6315-16 <br />>811 <br />240 <br />BC 0.82 <br />Vert(CT) <br />-0.8715-16 <br />>591 <br />180 <br />WB 0.47 <br />Horz(CT) <br />0.18 11 <br />n/a <br />n/a <br />Matrix-SH <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 239 lb FT = 20% <br />BRACING - <br />TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. <br />BOT CHORD Rigid ceiling directly applied or 4-6-14 oc bracing. <br />WEBS 1 Row at midpt 5-18, 8-13 <br />REACTIONS. (size) 2=0-3-8, 11=0-3-8 <br />Max Horz 2=127(LC 11) <br />Max Uplift 2=-943(LC 12), 11-943(1-C 12) <br />Max Grav 2=1642(LC 1),11=1642(LC 1) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=3606/2164, 3-4=-3350/1984, 4-5=3101/1890, 5-6=-4582/2725, 6-8=4582/2725, <br />8-9=-3101/1890, 9-10=-3350/1984, 10-11=-3606/2164 <br />BOTCHORD 2-18=-1889/3276, 16-18=-2429/4354, 15-16=-2620/4761, 13-15=-2412/4354, <br />11-13=-1906/3276 <br />WEBS 3-18=-266/323, 4-18=-519/1010, 5-18=1504/893, 5-116=140/447, 6-16=-291/242, <br />6-15=-291/242, 8-15=-140/447, 8-13=1504/893, 9-13=5'19/1010, 10-13=266/323 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 8-7-3, Exterior(2R) <br />8-7-3 to 14-8-3, Interior(1) 14-8-3 to 34-4-13, Exterior(21R) 34.4-13 to 40-5-12, Interior(1) 40-5-12 to 44-0-0 zone; cantilever left and <br />right exposed ; end vertical left and right exposed;C-C for members and forces 8r MWFRS for reactions shown; Lumber DOL=1.60 <br />plate grip DOL=1.60 <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />4) Provide adequate drainage to prevent water ponding. <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) <br />2=943, 11=943. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />2 <br />Iq <br />0 <br />This item has been <br />electronically signed and <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />doagaia VO- PE NoA9182 <br />]ffTeklac. DBA.LDIek GSA FLCeri6634 <br />16023 S.Ingley Ridge Rd. <br />C6esterr.w. \10 631117 <br />Date: <br />April 7,2023 <br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall ;� <br />building design. Bracing indicated is to prevent budding of individual truss web and/or chord members only. Additional temporary and permanent bracing Ml lek. <br />is always required for stability and to prevent collapse with possible personal injury and property damage, For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUMI Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd <br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />