Job
<br />Truss
<br />Truss Type
<br />Qty
<br />Ply
<br />T30256127
<br />TTH23-26
<br />T01
<br />Hip Girder
<br />2
<br />Job Reference (optional)
<br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Thu Apr 6 08:43:28 2023 Page 2
<br />I D: tP uYCeVfQTfYt3OC?ZvfnpzlG U H-_n4_m pj rP QsN s? N 48yn_i3Rt27m hT3Vn i EjoswzTUjz
<br />NOTES- (11)
<br />10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 124 lb down and 158 lb up at 6-2-6, 125 lb down and 153 lb up at
<br />8-3-2, 125 lb down and 153 lb up at 10-3-2, 124 lb down and 153 lb up at 12-3-2, 124 lb down and 153 lb up at 14-3-2, 124 lb down and 153 lb up at 16-3-2, 124 lb
<br />down and 153 lb up at 18-3-2, 124 lb down and 153 lb up at 20-3-2, 124 lb down and 153 lb up at 21-6-0, 124 lb down and 153 lb up at 22-8-14, 124 lb down and 153 lb
<br />up at 24-8-14, 124 lb down and 153 lb up at 26-8-14, 124 lb down and 153 lb up at 28-8-14, 124 lb down and 153 lb up at 30-8-14, 125 lb down and 153 lb up at
<br />32-8-14, and 125 lb down and 153 lb up at 34-8-14, and 225 lb down and 372 lb up at 36-9-10 on top chord, and 141 lb down at 6-2-6, 56 lb down at 8-3-2, 56 lb down
<br />at 10-3-2, 56 lb down at 12-3-2, 56 lb down at 14-3-2, 56 lb down at 16-3-2, 56 lb down at 18-3-2, 56 lb down at 20-3-2, 56 lb down at 21-6-0, 56 lb down at 22-8-14,
<br />56 lb down at 24-8-14, 56 lb down at 26-8-14, 56 lb down at 28-8-14, 56 lb down at 30-8-14, 56 lb down at 32-8-14, and 56 lb down at 34-8-14, and 141 lb down at
<br />36-8-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
<br />11) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of
<br />the building designer per ANSI TPI 1 as referenced by the building code."
<br />LOAD CASE(S) Standard
<br />1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
<br />Uniform Loads (plf)
<br />Vert: 1-3=-54, 3-9=54, 9-11=-54, 2-10=-20
<br />Concentrated Loads (lb)
<br />Vert: 3=-68(B) 9=-167(B) 20=88(13) 5=-68(B) 17=-28(B) 16=-28(B) 6=-68(B) 15=-28(B) 7=-68(B) 12=-88(B) 21=-68(B) 22=68(B) 23=-68(B) 24=-68(B) 25=-68(B)
<br />27=68(B) 28=-68(B) 30=-68(B) 31=68(B) 32=-68(B) 33=-68(B) 34=-68(B) 35=28(B) 36=-28(B) 37=-28(B) 38=-28(B) 39=-28(B) 40=-28(B) 41=-28(B) 42=-28(B)
<br />43=-28(B) 44=-28(B) 45=-28(B) 46=-28(B)
<br />O WARNING - Venty design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev 5/19/2020 BEFORE USE.
<br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
<br />a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall
<br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
<br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
<br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLITP11 quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd
<br />Safetylntormation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017
<br />
|