Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30256127 <br />TTH23-26 <br />T01 <br />Hip Girder <br />2 <br />n <br />L <br />Job Reference (optional) <br />builders FlrstSourCe (I ampa, FL), I ampa, FL - 33b64, 6.630 s Nov 19 2U22 MI I eK Industries, Inc. I Mu Apr 6 U6:43:26 2D23 Page 1 <br />ID:tPuYCeVfQTfYt30C?ZvfnpzlGU H-_n4_mpjrPQsNs?N48yn_i3Rt27mhT3VniEjoswzTUjz <br />-1-0-p 6-2-6 11-4-12 16-5-6 21-6-0 26-6-10 31-7-4 36-9-10 43-0-0 4,4-0-p <br />0- 6-2 6 5-2 6 5-0-10 5-0-10 5-0-10 5-0-10 + 5-2-6 6-2 6 0- <br />5.00 F12 6x8 = 2x4 II <br />3 21 22 4 23 <br />48 = 7x8 = 4x8 = 2x4 11 6x8 = <br />24 5 2526 27 6 28 2930 7 31 32 8 33 34 9 <br />Scale = 1:74.0 <br />5x8 = 20 35 36 19 37 38 18 17 39 40 16 41 42 15 1443 44 13 45 46 12 5x8 = <br />2x4 11 5x8 = 7x8 WB = 48 = 2x4 11 5x8 = 2x4 11 <br />2x4 I I 7x8 WB = <br />6-2-6 11-4-12 16-5-6 21-" 26-6-10 31-74 <br />LOADING (psf) <br />TCLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr NO <br />Code FBC2020/TPI2014 <br />CSI. <br />TC 0.57 <br />BC 0.35 <br />WB 0.72 <br />Matrix-SH <br />DEFL. in <br />Vert(LL) 0.82 <br />Vert(CT) -0.96 <br />Horz(CT) 0.13 <br />(loc) I/deft L/d <br />16 >625 240 <br />16 >534 180 <br />10 n/a n/a <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 531 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 *Except* TOP CHORD <br />Structural wood sheathing directly applied or 4-4-13 oc purlins. <br />3-6,6-9: 2x6 SP No.2 BOT CHORD <br />Rigid ceiling directly applied or 8-1-10 oc bracing. <br />BOT CHORD 2x6 SP M 26 <br />WEBS 2x4 SP No.3 <br />OTHERS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=94(LC 24) <br />Max Uplift 2=-1645(LC 8), 10=1722(1-C 8) <br />Max Grav 2=2532(LC 1), 10=2602(LC 1) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-5972/3778, 3-4=-8812/5811, 4-5=8810/5809, 5-6=1150917662, 6-7=11509/7662, <br />7-8=-8924/5934, 8-9=-8926/5936, 9-1 0=-6152/3976 <br />BOT CHORD 2-20=-3371/5458, 19-20=-3370/5475, 17-19=-7060/10895, 16-17=7060/10895, <br />15-16=-7123/10952, 13-15=7123/10952, 12-13=3553/5641, 10-12=3554/5625 <br />WEBS 3-20=0/450, 3-19=2515/3773, 4-19=-495/505, 5-19=-2340/1584, 5-17=0/383, <br />5-16=-539/717, 6-16=-447/498, 7-16=-454/643, 7-15=0/383, 7-13=-2267/1515, <br />8-13=-495/505, 9-13=-2451/3705, 9-12=0/449 <br />NOTES- (11) <br />1) 2-ply truss to be connected together with 1 Od (0.131 "x3") nails as follows: <br />Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-M oc. <br />Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. <br />This Item has been <br />Webs connected as follows: 2x4 -1 row at 0-9-0 oc. <br />electronically signed and <br />2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to <br />sealed by Velez, Joaquin, PE <br />ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. <br />Using a Digital Signature. <br />3) Unbalanced roof live loads have been considered for this design. <br />4) Wind: ASCE 7-16; VuIt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />Printed copies of this <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber <br />document are not considered <br />DOL=1.60 plate grip DOL=1.60 <br />signed and sealed and the <br />5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />nature must be verified <br />signature <br />to the use of this truss component. <br />6) Provide adequate drainage to prevent water ponding. <br />On any electronic Copies. <br />7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />Juagnlu V.1ez PE Xu.611192 <br />8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />MiTek Luc. DBA 3BTek C5A FL Cen 6634 <br />will fit between the bottom chord and any other members. <br />16021 Soiugley Ridge Rd. <br />cLerlrrficla. ilo 630v <br />9 Provide mechanical connection b others of truss to bearing late capable of withstanding 100 lb uplift at joints except Ib <br />(Y ) 9 P P 9 P 1 OIlt= ) <br />Darr: <br />2=1645,10=1722. <br />April 7,2023 <br />WARNING - Venfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-8e and SCSI Building Component 16023 Swingley Ridge Rd <br />Safetyinformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />