Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30256133 <br />TTH23-26 <br />T05A <br />Hip <br />1 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Thu Apr 6 08:43:42 2023 Page 1 <br />I D: tP uYCeVfQTfYt3OC?ZvfnpzlG U H-aTxH ibud6jdOX8Rnzv2 H H 009tm O R I U arwQ6YL6zTUj I <br />15-9-10 27-2-6 34-7-12 43-0-0 <br />8-4-4 7-5-5 5-8 6 5-Sb 7-5-5 <br />yI <br />0 <br />2x4 II 5x6 = 3x8 = 5x6 = <br />8-4-4 15-9-10 21-" 27-2-6 <br />Scale = 1:75.6 <br />5.00 F12 5x8 = 2x4 II 5x8 = <br />5 17 6 1819 20 7 <br />3x8 = 15 14 ZZ 13 Z3 12 11 3x8 = <br />2x4 II <br />LOADING (psf) <br />TCLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr YES <br />Code FBC2020/TPI2014 <br />CSI. <br />TC 1.00 <br />BC 0.90 <br />WB 0.36 <br />Matrix-SH <br />DEFL. in (loc) Udefl Ud <br />Vert(LL) 0.36 13 >999 240 <br />Vert(CT) -0.56 12-13 >918 180 <br />Horz(CT) 0.20 10 n/a n/a <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 220 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 "Except" TOP CHORD Structural wood sheathing directly applied. <br />1-4,8-10: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-4-12 oc bracing. <br />BOT CHORD 2x4 SP No.1 'Except* WEBS 1 Row at midpt 3-14, <br />9-12 <br />12-14: 2x4 SP No.2 <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=221(LC 11) <br />Max Uplift 2=-944(LC 12), 10=-857(LC 12) <br />Max Grav 2=1861(LC 17), 10=1807(LC 18) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3889/2054, 3-5=-2974/1694, 5-6=2884/1753, 6-7=-2884/1753, 7-9=2975/1694, <br />9-10=-3884/2055 <br />BOT CHORD 2-15=-1797/3663, 14-15=-1797/3663, 13-14=-1261/2779, 12-13=1249/2675, <br />11-12=-1791/3514, 10-11=-1791/3514 <br />WEBS 3-15=0/345, 3-14=-980/593, 5-14=209/669, 5-13=-199/448, 6-13=-337/306, <br />7-13=-196/447, 7-12=-212/672, 9-12=989/600, 9-11=0/346 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />11; Exp C; Encl., GCpi=O.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 15-9-10, Exterior(2R) <br />15-9-10 to 21-10-9, Interior(1) 21-10-9 to 27-2-6, Exterior(2R) 27-2-6 to 33-3-6, Interior(1) 33-3-6 to 42-10-4 zone; cantilever left and <br />This item has been <br />right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 <br />electronically signed and <br />plate grip DOL=1.60 <br />sealed by Velez, Joaquin, PE <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />using a Digital Signature. <br />to the use of this truss component. <br />4) Provide adequate drainage to prevent water ponding. <br />Printed Copies of this <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />document are not considered <br />6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />signed and sealed and the <br />will fit between the bottom chord and any other members, with BCDL = 10.Opsf. <br />signature <br />nature must be verified <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) <br />2=944, 10=857. <br />on any electronic copies. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />2e.gnie Velez PE nu 6sts2 <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />1111ek Luc. DBA SBTek USA FL cert6&ii <br />16023 Swingle} Ridge Rd <br />che.ter6eM. %to 6ml-, <br />Dae: <br />April 7,2023 <br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. <br />Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, we ANSYTP1 f Quality Criteria, DS849 and BCSI Building Component 16023 Swingley Ridge Rd <br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />