Job
<br />Truss
<br />Truss Type
<br />Qty
<br />Ply
<br />T30256133
<br />TTH23-26
<br />T05A
<br />Hip
<br />1
<br />1
<br />Job Reference (optional)
<br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Thu Apr 6 08:43:42 2023 Page 1
<br />I D: tP uYCeVfQTfYt3OC?ZvfnpzlG U H-aTxH ibud6jdOX8Rnzv2 H H 009tm O R I U arwQ6YL6zTUj I
<br />15-9-10 27-2-6 34-7-12 43-0-0
<br />8-4-4 7-5-5 5-8 6 5-Sb 7-5-5
<br />yI
<br />0
<br />2x4 II 5x6 = 3x8 = 5x6 =
<br />8-4-4 15-9-10 21-" 27-2-6
<br />Scale = 1:75.6
<br />5.00 F12 5x8 = 2x4 II 5x8 =
<br />5 17 6 1819 20 7
<br />3x8 = 15 14 ZZ 13 Z3 12 11 3x8 =
<br />2x4 II
<br />LOADING (psf)
<br />TCLL 20.0
<br />TCDL 7.0
<br />BCLL 0.0
<br />BCDL 10.0
<br />SPACING- 2-0-0
<br />Plate Grip DOL 1.25
<br />Lumber DOL 1.25
<br />Rep Stress Incr YES
<br />Code FBC2020/TPI2014
<br />CSI.
<br />TC 1.00
<br />BC 0.90
<br />WB 0.36
<br />Matrix-SH
<br />DEFL. in (loc) Udefl Ud
<br />Vert(LL) 0.36 13 >999 240
<br />Vert(CT) -0.56 12-13 >918 180
<br />Horz(CT) 0.20 10 n/a n/a
<br />PLATES GRIP
<br />MT20 244/190
<br />Weight: 220 lb FT = 20%
<br />LUMBER- BRACING -
<br />TOP CHORD 2x4 SP No.2 "Except" TOP CHORD Structural wood sheathing directly applied.
<br />1-4,8-10: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-4-12 oc bracing.
<br />BOT CHORD 2x4 SP No.1 'Except* WEBS 1 Row at midpt 3-14,
<br />9-12
<br />12-14: 2x4 SP No.2
<br />WEBS 2x4 SP No.3
<br />REACTIONS. (size) 2=0-3-8, 10=0-3-8
<br />Max Horz 2=221(LC 11)
<br />Max Uplift 2=-944(LC 12), 10=-857(LC 12)
<br />Max Grav 2=1861(LC 17), 10=1807(LC 18)
<br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
<br />TOP CHORD 2-3=-3889/2054, 3-5=-2974/1694, 5-6=2884/1753, 6-7=-2884/1753, 7-9=2975/1694,
<br />9-10=-3884/2055
<br />BOT CHORD 2-15=-1797/3663, 14-15=-1797/3663, 13-14=-1261/2779, 12-13=1249/2675,
<br />11-12=-1791/3514, 10-11=-1791/3514
<br />WEBS 3-15=0/345, 3-14=-980/593, 5-14=209/669, 5-13=-199/448, 6-13=-337/306,
<br />7-13=-196/447, 7-12=-212/672, 9-12=989/600, 9-11=0/346
<br />NOTES- (8)
<br />1) Unbalanced roof live loads have been considered for this design.
<br />2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat.
<br />11; Exp C; Encl., GCpi=O.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 15-9-10, Exterior(2R)
<br />15-9-10 to 21-10-9, Interior(1) 21-10-9 to 27-2-6, Exterior(2R) 27-2-6 to 33-3-6, Interior(1) 33-3-6 to 42-10-4 zone; cantilever left and
<br />This item has been
<br />right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60
<br />electronically signed and
<br />plate grip DOL=1.60
<br />sealed by Velez, Joaquin, PE
<br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
<br />using a Digital Signature.
<br />to the use of this truss component.
<br />4) Provide adequate drainage to prevent water ponding.
<br />Printed Copies of this
<br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
<br />document are not considered
<br />6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
<br />signed and sealed and the
<br />will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
<br />signature
<br />nature must be verified
<br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
<br />2=944, 10=857.
<br />on any electronic copies.
<br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any
<br />2e.gnie Velez PE nu 6sts2
<br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
<br />1111ek Luc. DBA SBTek USA FL cert6&ii
<br />16023 Swingle} Ridge Rd
<br />che.ter6eM. %to 6ml-,
<br />Dae:
<br />April 7,2023
<br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
<br />Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
<br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
<br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek"
<br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
<br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, we ANSYTP1 f Quality Criteria, DS849 and BCSI Building Component 16023 Swingley Ridge Rd
<br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017
<br />
|