Job
<br />Truss
<br />Truss Type
<br />Qty
<br />Ply
<br />T30256134
<br />TT1123-26
<br />T06
<br />Hip
<br />1
<br />1
<br />Job Reference (optional)
<br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Thu Apr 6 08:43:44 2023 Page 1
<br />I D: tPuYCeVfQTfYt3OC?ZvfnpzlG U H-Ws227HvteLt5m Sb94J41M R5Xoa3d D E H 8N kbeQ?zTUjj
<br />-11-0-Q 6-G-0 121-3 18-2-6 24-9-10 30-7-13 36-6-0 43-0-0 4p-0-p
<br />5-10-3 5-10-3 6-7-3 5-10-3 5-10-3
<br />5.00 F12 5x6 =
<br />620
<br />5x8 =
<br />721
<br />Scale = 1:75.7
<br />3x8 = -10 Za Z4 -11 16 do 15 -Iv tD a Is 3x8 —
<br />3x4 = 4x6 = 3x8 =
<br />3x4 = 4x6
<br />3x4 =
<br />43-0-0
<br />i7.
<br />0
<br />LOADING (psf)
<br />SPACING- 2-0-0
<br />CSI.
<br />DEFL. in (loc) Ildefl L/d
<br />PLATES GRIP
<br />TCLL 20.0
<br />Plate Grip DOL 1.25
<br />TC 0.84
<br />Vert(LL) -0.40 13-15 >999 240
<br />MT20 244/190
<br />TCDL 7.0
<br />Lumber DOL 1.25
<br />BC 0.98
<br />Vert(CT) -0.70 13-15 >733 180
<br />BCLL 0.0
<br />Rep Stress Incr YES
<br />WB 0.99
<br />Horz(CT) 0.20 11 n/a n/a
<br />BCDL 10.0
<br />Code FBC2020/TP12014
<br />Matrix-SH
<br />Weight: 223 lb FT = 20%
<br />LUMBER- BRACING -
<br />TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.
<br />BOT CHORD 2x4 SP No.1 'Except* BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing, Except:
<br />14-17: 2x4 SP No.2 5-8-0 oc bracing: 15-16.
<br />WEBS 2x4 SP No.3 WEBS 1 Row at midpt
<br />7-16
<br />REACTIONS. (size) 2=0-3-8, 11=0-3-8
<br />Max Horz 2=254(LC 11)
<br />Max Uplift 2=-943(LC 12), 11=9431LC 12)
<br />Max Grav 2=1872(LC 17), 11=1876(LC 18)
<br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
<br />TOP CHORD 2-3=-3934/2082, 3-5=-3692/1963, 5-6=2723/1603, 6-7=2481/1552, 7-8=-2733/1603,
<br />8-1 0=-3702/1963, 10-11 =-3943/2082
<br />BOT CHORD 2-18=-1800/3760, 16-18=-147013172, 15-16=-1093/2484, 13-15=1483/3010,
<br />11-13=-1813/3578
<br />WEBS 3-18=-333/332, 5-18=-192/687, 5-16=820/522, 6-16=-296/753, 7-15=-297/836,
<br />8-15=-820/522, 8-13=-192/687, 10-13=333/332
<br />NOTES- (8)
<br />1) Unbalanced roof live loads have been considered for this design.
<br />2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat.
<br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 18-2-6, Exterior(2R)
<br />18-2-6 to 24-3-6, Interior(1) 24-3-6 to 24-9-10, Exterior(2R) 24-9-10 to 30-7-13, Interior(1) 30-7-13 to 44-0-0 zone; cantilever left and
<br />right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60
<br />This item has been
<br />plate grip DOL=1.60
<br />electronically signed and
<br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
<br />sealed by Velez, Joaquin, PE
<br />to the use of this truss component.
<br />using a Digital Signature.
<br />4) Provide adequate drainage to prevent water ponding.
<br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
<br />Printed Copies Of this
<br />6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-&0 tall by 2-0-0 wide
<br />document are not considered
<br />will fit between the bottom chord and any other members, with BCDL=10.Opsf.
<br />signed and sealed and the
<br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
<br />signature must be verified
<br />g
<br />2=943, 11=943.
<br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any
<br />on any electronic copies.
<br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
<br />Joegain %0-PE Ne.681S2
<br />\BTek Luc. DBA 1BTek USA FL Cen 66-4
<br />16023 SMugley Ridge Rd.
<br />Chesterfield. NIO 63017
<br />Date:
<br />April 7,2023
<br />WARNING - Venfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
<br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
<br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall _
<br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
<br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
<br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Qualify Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd
<br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suds 203 Waldorf, MD 20601 Chesterfield, MO 63017
<br />
|