Laserfiche WebLink
Job <br />russ <br />Truss Type <br />Ply <br />Dupont <br />T20455627 <br />772591-X <br />A9 <br />Hip <br />�Qty <br />1 <br />1 <br />Job Reference (optional) <br />American Builder Supply, Sanford, FL 8.330 s May 6 2020 MiTek Industries, Inc. Fri Jun 12 13:48:51 2020 Page 1 <br />ID: RWGiORDiF509gYXBdOupOozldd5-yxo6mYwjGugc5300ZQa?THspeDucZpf?38J 1 Qz7?th <br />7.6-0 15-0-0 17 23-8-0 31-2-0 38$-0 3 <br />0-0 72-0 7-6 0 2 0 0 4 6A 2-0.0 7-6-0 7-6-0 0-0 <br />Scale = 1:71.2 <br />3x6 = <br />10-0-0 <br />5.00 12 <br />5x8 = <br />3x4 i <br />5x6 = <br />5x6 = 3x4 <br />6 7 <br />7x8 = 4x6 = 3x4 = <br />3x8 = <br />LOADING (psf) <br />TCLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr YES <br />Code FBC2017/TPI2014 <br />CSI. <br />TC 0.62 <br />BC 0.95 <br />WB 0.80 <br />Matrix -AS <br />DEFL. <br />Vert(ILL) <br />Vert(CT) <br />Horz(CT) <br />Wtnd(LL) <br />in (Joe) Udefl Lid <br />-0.32 13-14 >999 360 <br />-0.58 13-14 >801 240 <br />0.13 9 rile n/a <br />0.28 13 >999 240 <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 201 lb FT = 20% <br />LUMBER- <br />BRACING - <br />TOP CHORD 2x4 SP No.2 <br />TOP CHORD <br />Structural wood sheathing directly applied. <br />BOT CHORD 2x4 SP M 30 "Except` <br />BOT CHORD <br />Rigid ceiling directly applied. <br />12-14: 2x4 SP No.2 <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-8-0, 9=0-8-0 <br />Max Horz 2=-279(LC 10) <br />Max Uplift 2=716(1_C 12), 9=716(LC 12) <br />Max Grav 2=1506(LC 17), 9=1506(LC 18) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3123/1806, 3-4=-2883/1704, 4-5=1933/1326, 5-6=1952/1342, 6-7=1933/1326, <br />7-8=2883/1704, 8-9=-3123/1806 <br />BOTCHORD 2-14=-1545/3041, 13-14=-1079/2237, 11-13=-1087/2100, 9-11=-1553/2831 <br />WEBS 3-14=-478/443, 4-14=-300/805, 4-13=726/589, 5-13=-3981662, 7-11=-299/804, <br />8-11=-478/443, 7-13=727/589, 6-113=398/663 <br />NOTES- <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=58ft; L=39ft; eave=5ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0.0 to 2-10-6, Interior(1) 2-10-6 to 17-0-0. Exterior(2) 17-0-0 <br />to 27-1-10, Interior(1) 27-1-10 to 39-8-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate <br />grip DOL=1.60 <br />3) Provide adequate drainage to prevent water ponding. <br />4) All plates are MT20 plates unless otherwise indicated. <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will Tit between the bottom chord and any other members, with BCDL = 10.Opsf. <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 716 lb uplift at joint 2 and 716 lb uplift at <br />joint 9. <br />8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum <br />sheetrock be applied directly to the bottom chord. <br />I1/11111/1�� <br />pous <br />GENS• ..�40 <br />No 34869 <br />�� • IA,�L,�l.a 11 Q � <br />Julius Loa PE No.34869 <br />MiTek USA, Inc. FL Gen 6634 <br />6904 Parke East Blvd. Tampa FL 33610 <br />Date: <br />June 12,2020 <br />AWARNING -Verify design parameters and READ NOTES ON TMS AND INCLUDED MITEK REFERENCE PAGE MIF7473 rev. 1010312015 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />- <br />a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall <br />building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M!Tek- <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI Qu&ft CNfarla, DS849 and SCSI BulkUng Component 6904 Parke East Blvd, <br />Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 <br />