Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />Dupont <br />T20455628 <br />772591-X <br />A10 <br />Hip <br />1 <br />1 <br />Job Reference (optional) <br />American Builder Supply, Sanford, FL 8.330 s May 6 2020 MiTek Industries, Inc. Fri Jun 12 13:48:34 2020 Page 1 <br />ID: RWGiORDIF509gYXBdOupOozldd5-Qsg3UJMuVLtxherySC7pM5d58CmBtQYJKaGTSNz7?tx <br />1-0 Q 7 6 0 15-0-0 19-0-0 23-8-O 31-2-0 _ 38 6-0 3A-8-Q <br />700� 720P 7S0 4�-0 440 780 _ 760 ' <br />5.00 12 <br />5x8 = 2x4 11 5x8 = <br />4 22 5 23 6 <br />l:1 zo L/ 12 Lull Le lU <br />5x8 = <br />Us = <br />3x8 = <br />Us = 3x4 = <br />3x8 = <br />Scale = 1:71.2 <br />10-0-0 194-0 <br />28-" <br />38-8-0 <br />10-" 9-4-0 <br />94-0 <br />10-04) <br />Plate Offsets (X,Y)— <br />[2:0-0-2,Edge], [3:0-3-0,0-3-4], [4:0-4-0,0-1-131, [6:0-4-0,0-1-131, [7:0-3-0,0-3-4], [8:0-4-2,0-1-8], [13:0-4-0 0-3-0] <br />LOADING (psf) <br />SPACING- 24)-0 <br />CSI. <br />DEFL. in (loc) I/deft L/d <br />PLATES GRIP <br />TCLL 20.0 <br />Plate Grip DOL 1.25 <br />TC 0.73 <br />Vert(LL) -0.32 12-13 >999 360 <br />MT20 2441190 <br />TCDL 7.0 <br />Lumber DOL 1.25 <br />BC 0.95 <br />Vert(CT) -0.58 12-13 >798 240 <br />BCLL 0.0 <br />Rep Stress Incr YES <br />WB 0.44 <br />Horz(CT) 0.13 8 file n/a <br />BCDL 10.0 <br />Code FBC2017/TP12014 <br />Matrix -AS <br />Wind(LL) 0.28 12 >999 240 <br />Weight: 188 lb FT = 20% <br />LUMBER- <br />BRACING - <br />TOP CHORD 2x4 SP No.2 <br />TOP CHORD Structural wood sheathing directly applied. <br />BOT CHORD 2x4 SP M 30 `Except' <br />BOT CHORD Rigid ceiling directly applied. <br />11-13: 2x4 SP No.2 <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-8-0, 8=0-8-0 <br />Max Horz 2=-248(LC 10) <br />Max Uplift 2=716(LC 12), 8=-716(LC 12) <br />Max Grav 2=1509(LC 17), 8=1509(LC 18) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3132/1874, 3-4=-2889/1758, 4-5=-2228/1510, 5-6=2228/1510, 6-7=2889/1758, <br />7-8=313211874 <br />BOT CHORD 2-13=-1611/3026, 12-13=-1080/2209, 1D-12=-1089/2091, 8-10=-1619/2840 <br />WEBS 3-13=-490/496, 4-13=-349/817, 4-12=1051408, 6-12=-105/409, 6-10=-349/816, <br />7-10=-490/496 <br />NOTES- <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=58ft; L=39ft; eave=5ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS C-C Exterior(2) to 2-10-6, Interior(1) 2-10-6 to 15.0-0, Exterior(2) 15-0-0 <br />30V$ <br />F I4# <br />(directional) and -1-0-0 <br />�� .. • <br />G E N S+'•. �s►� <br />to 20-5-10, Interior(1) 20-5-10 to 23-8-0, Exterior(2) 23-8-0 to 29-1-10. Interior(1) 29-1-10 to 39-8-0 zone;C-C for members and <br />,�� .•'� <br />F �•.� <br />forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />�� .0� <br />3) Provide adequate drainage to prevent water ponding. <br />4) All plates are MT20 plates unless otherwise indicated. <br />NO 34869 <br />•� <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members, with BCDL = IO.Opsf. <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (t=lb) <br />2=716, 8=716. <br />8) This truss design requires that a minimum of 7/16' structural wood sheathing be applied directly to the top chord and 1/2" gypsum <br />'�� • O `ID <br />sheetrock be applied directly to the bottom chord. <br />S1 •., • R �,. <br />I • <br />I5'O N A' <br />Julius Lee PE No.34869 <br />M[Tek USA, Inc. FL Cert 6634 <br />6904 Parke Fast Blvd. Tampa FL 33610 <br />Date: <br />June 12,2020 <br />a WARNING - Vedly design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/032015 BEFORE USE. <br />., Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />MiTek° <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/lPlf Quality Criterfa, DSB-89 and BCSI Building Component <br />69D4 Parke East Blvd. <br />Saretyinformation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. <br />Tampa, FL 36610 <br />