My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36820 Precita Ter (2)
Zephyrhills
>
Building Department
>
Building Plans
>
36820 Precita Ter (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 10:14:43 AM
Creation date
2/19/2025 9:06:49 AM
Metadata
Fields
Template:
Building Plans
Street #
36820
Location
Precita Ter
Contractor
K Hovnanian
Building Plans - Permit #
311
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job <br />cuss <br />Truss Type <br />Ply <br />Dupont <br />T20455629 <br />772591-X <br />A11 <br />Hip <br />�Qty <br />1 <br />1 <br />Job Reference (optional) <br />American Builder Supply, Sanford, FL 8.330 s May 6 2020 MiTek Industries, Inc. Fri Jun 12 13:48:35 2020 Page 1 <br />ID: RWGiORDIF509gYXBdOupOozldd5-u2ORifNWFf?oJnQ8?we3vl9HPb4CcuOSYD01?pz7?tw <br />1 7 6 0 13-0-0 19-4-0 25 8 0 31-2-0 38-8-0 <br />0 0 76 0 5 6-0 6-4-0 6 4-0 5 6 0 7-11 0.0 <br />5x6 = 2x4 II 5x6 = <br />4 21 22 5 23 24 6 <br />IJ LO Lr 12 -.. zo zu -IV <br />3x8 = 5x8 = 3x8 = 44 = 3x4 = <br />3x8 = <br />Scale = 1:69.9 <br />LOADING (psf) <br />TCLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr YES <br />Code FBC2017/TPI2014 <br />CSI. <br />TC 0.70 <br />BC 0.96 <br />WB 0.34 <br />Matrix -AS <br />DEFL. <br />Vert(LL) <br />Vert(CT) <br />Horz(CT) <br />Wind(LL) <br />in (loc) Well L/d <br />-0.29 12-13 >999 360 <br />-0.55 12-13 >836 240 <br />0.13 8 n/a n/a <br />0.31 12 >999 240 <br />PLATES GRIP <br />MT20 2441190 <br />Weight: 183 lb FT = 20% <br />LUMBER- <br />BRACING - <br />TOP CHORD 2x4 SP No.2 <br />TOP CHORD <br />Structural wood sheathing directly applied. <br />BOT CHORD 2x4 SP M 30 -Except- <br />BOT CHORD <br />Rigid ceiling directly applied. <br />11-13: 2x4 SP No.2 <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-8-0, 8=0-8-0 <br />Max Horz 2=217(LC 11) <br />Max Uplift 2=-716(LC 12), 8=716(LC 12) <br />Max Grav 2=1485(LC 1), 8=1485(LC 1) <br />FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3065/1895, 3-4=-2826/1780, 4-5=2586/1716, 5-6=2586/1716, 6-7=2827/1780, <br />7-8=3066/1895 <br />BOT CHORD 2-13=-1626/2913, 12-13=-1206/2314, 10-12=-1213/2267, 8-10=-1633/2790 <br />WEBS 3-13=-425/449, 4-13=-273/678, 4-12=252/567, 5-12=-384/390, 6-12=-251/566, <br />6-10=-273/678, 7-10=-425/449 <br />NOTES- <br />is design. <br />of live <br />s have been considered for <br />2) Wind: <br />hC-C4Exterior() <br />1111 <br />C; Encl., GCp 018; MWF Ss (directionnd al) 1-0-0 o 2 10-6 Irlterior(1) 10-6 to 113-0-0, Exterior(2) 13-0-0 <br />���,���j� <br />and <br />,`��,,,��Uus' <br />to 18-5-10, Interior(1) 18-5-10 to 25-8-0, Exterior(2) 25-8-0 to 31-3-3, Interior(1) 31-3-3 to 39-8-0 zone;C-C for members and forces & <br />♦♦ ••••� C E N S+'•.• I1 <br />F <br />MWFRS or reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />♦ V <br />3) Provide adequate drainage to prevent water ponding. <br />34869 <br />4) All plates are MT20 plates unless otherwise indicated. <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members, with BCDL = 10.Opsf. <br />'0 <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift at joint(s) except (jt=lb) <br />„13 �• •• i(/ <br />2-716, 8=716. <br />8) This truss design requires that a minimum of 7116" structural wood sheathing be applied directly to the top chord and 1/2" gypsum <br />��i'� •' ( P;•• ����♦ <br />O 0 R <br />sheetrock be applied directly to the bottom chord. <br />�j� ♦♦ <br />Julius Lee PE No.34869 <br />MITek USA, Inc. FL Cert 6634 <br />6904 Parke East Blvd. Tampa FL 33610 <br />Date: <br />June 12,2020 <br />A WARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 41II-7473 rev. 1010312016 BEFORE USE. <br />Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />M iTek" <br />Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Crffalfa, DSB49 and SCSI Building Component <br />6904 Parke East Blvd. <br />Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. <br />Tampa, FL 36610 <br />
The URL can be used to link to this page
Your browser does not support the video tag.