My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (136)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (136)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 11:26:50 AM
Creation date
2/28/2025 8:03:43 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Brasfield and Gorrie LLC
Building Plans - Permit #
17470
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES: <br />1. THIS PRODUCT HAS BEEN TESTED, ANALYZED & APPROVED FOR DESIGN <br />PRESSURES NOT TO EXCEED THOSE SHOWN IN THE "ALLOWABLE DESIGN PRESSURE <br />TABLES)". <br />7- OPENINGS, BUCKING & BUCKING FASTENERS MUST BE PROPERLY DESIGNED & <br />INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. <br />3. ALL HARDWARE & FASTENERS SHALL BE IN ACCORDANCE WITH THESE DRAWINGS <br />& SHALL NOT VARY UNLESS SPECIFICALLY MENTIONED ON THE DRAWINGS. SPECIFIED <br />ANCHOR EMBED TO BASE MATERIAL SHALL BE BEYOND WALL FINISH OR STUCCO. <br />4. THIS PRODUCT HAS BEEN DESIGNED IN ACCORDANCE WITH AND MEETS THE <br />REQUIREMENTS OF THE FLORIDA BUILDING CODE (FBC) INCLUDING HIGH VELOCITY <br />HURRICANE ZONES (WHIZ) & IS SMALL MISSILE IMPACT RATED. <br />5. THIS PRODUCT MAY NOT BE INSTALLED AT ELEVATIONS BELOW 30 FT. ABOVE <br />GRADE OR AT ANY CODE DESIGNATED LARGE MISSILE IMPACT LOCATION WITHOUT AN <br />APPROVED SHUTTER. <br />6. ALL ANCHORS SECURING PRODUCT FRAMES TO PRESSURE TREATED BUCKS OR <br />WOOD FRAMING SHALL BE CAPABLE OF RESISTING CORROSION CAUSED BY THE, <br />PRESSURE TREATING CHEMICALS IN THE WOOD. <br />7. DETERMINE THE POSITIVE & NEGATIVE DESIGN LOADS TO USE WHEN <br />REFERENCING THESE DOCUMENTS IN ACCORDANCE WITH THE GOVERNING CODE AND <br />GOVERNING WIND VELOCITY. FOR WIND LOAD CALCULATIONS IN ACCORDANCE WITH <br />THE FLORIDA BUILDING CODE, A DIRECTIONALITY FACTOR OF Kd = 0.85 MAY BE <br />APPLIED PER THE ASCE-7 STANDARD. <br />S. MATERIALS, INCLUDING BUT NOT LIMITED TO STEEL SCREWS, THAT COME INTO <br />CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF <br />FLORIDA BUILDING CODE. <br />9. TO THE BEST OF OUR KNOWLEDGE, THE PRODUCT SHOWN HEREIN IS QUALITY <br />ASSURED BY A FLORIDA STATE APPROVED CERTIFICATION/QA ENTITY & SHALL BE <br />LABELED IN ACCORDANCE- WITH THE FBC AND THE FLORIDA DEPARTMENT OF <br />'BUSINESS & PROFESSIONAL REGULATION SPECIFICATIONS. THESE DRAWINGS SHOW <br />ALL APPLICABLE ELEVATION, COMBINATION, INSTALLATION & COMPARATIVE ANALYSIS <br />CONDITIONS AS DETERMINED THROUGH TESTING & ENGINEERING RATIONAL ANALYSIS. <br />PRODUCT ASSEMBLY SHALL BE IN ACCORDANCE WITH THESE DRAWINGS, THE <br />MANUFACTURERS QUALITY ASSURANCE SPECIFICATIONS & TESTING REPORTS. <br />10. CERTIFICATION OF THIS PRODUCT SHALL BE.CONSIDERED VOID IF IT IS INSTALLED <br />WITHOUT A BUILDING PERMIT FROM THE APPLICABLE LOCAL BUILDING DEPARTMENT OR <br />IF IT IS INSTALLED BY ANYONE OTHER THAN A LICENSED CONTRACTOR EXPERIENCED <br />WITH INSTALLATIONS OF THIS TYPE OF PRODUCT. <br />DRAWING USE INSTRUCTIONS: <br />1. DETERMINE IF. THE WALL SYSTEM IS TO BE A MULTI -SPAN, REINFORCED <br />SINGLE SPAN, OR NON -REINFORCED SINGLE SPAN CONDITION. IF <br />MULTI -SPAN, ALL CONDITIONS SHOWN ON SHEETS 2 & 3 SHALL APPLY. IT <br />A REINFORCED SINGLE SPAN, ALL CONDITIONS SHOWN ON SHEET 4 SHALL <br />APPLY. IF A NON -REINFORCED SINGLE SPAN, ALL CONDITIONS SHOWN ON <br />SHEET 5 SHALL APPLY. <br />2. CONDITIONS MAY NOT BE MIXED BETWEEN WALL SYSTEM TYPES, <br />3. ALLOWABLE GLASS PRESSURE SHALL BE CONSIDERED WITH ALL WALL <br />CONDITIONS AND SHALL CONTROL IF LESS THAN THOSE ALLOWABLE <br />PRESSURES STATED FOR THE APPLICABLE FRAMING SYSTEM. <br />FREE SPANNING IA►AB PERIMETER SEAT ANT NOTE (APPLICABLE TO <br />R EVATION ON SHEET 5)- <br />WHEN THERE IS NO CONTINUOUS JAMB SUPPORT, THE MINIMUM & <br />MAXIMUM ALLOWABLE SPACE BETWEEN JAMB FRAME MEMBERS & THE <br />OPENING SUBSTRATE OR FINISHES SHALL BE SPECIFIED BY THE ENGINEER <br />OR ARCHITECT OF RECORD FOR EACH JOB BUT SHALL NOT BE LESS <br />THAN 1/2" NOR GREATER THAN 1 3/8". WHEN CONSIDERING TYPE, <br />DEPTH & JOINT SPAN OF SEALANT, THE ENGINEER/ARCHITECT SHALL <br />TAKE INTO CONSIDERATION THE DEFLECTION -OF THE JAMB MEMBER THAT <br />WOULD OCCUR WHILE SUPPORTING THE JOB REQUIRED DESIGN WIND <br />PRESSURE. ALSO TO BE CONSIDERED SHALL BE THE MATERIALS & <br />SURFACES TO WHICH THE SEALANT WILL BE APPLIED. <br />CORNER CONSTRUCTION: <br />STANDARD FRAMING AT TOP & BOTTOM HORIZONTAL MEMBERS: VERTICAL <br />MEMBERS RUN THROUGH WHILE THE HORIZONTAL MEMBERS ARE SQUARE CUT, <br />BUTTED AND MECHANICALLY FASTENED TO THE VERTICAL MEMBERS VIA A <br />SHEAR BLOCK (ITEM #14). THE SHEAR BLOCK IS MECHANICALLY FASTENED TO <br />THE VERTICAL FRAME MEMBER WITH 2 NO. 12 X 1 7/8" FHTF SCREWS. THE <br />HORIZONTAL FRAME MEMBERS ARE ATTACHED TO THE SHEAR BLOCK WITH 2 <br />NO. 12 X 7/8" PHTF SCREWS. CORNERS ARE SEALED WITH DOW 795 <br />SILICONE SEALANT. <br />STANDARD FRAMING AT INTERMEDIATE HORIZONTAL MEMBERS: HORIZONTAL <br />MEMBERS ARE SQUARE CUT, BUTTED AND MECHANICALLY FASTENED TO THE <br />VERTICAL FRAME MEMBERS VIA A SHEAR BLOCK (REM #16). THE SHEAR <br />BLOCK IS MECHANICALLY FASTENED TO THE VERTICAL FRAME MEMBER WITH 2 <br />NO. 12 X 1 7/8" FHTF SCREWS. THE INTERMEDIATE HORIZONTAL FRAME <br />MEMBERS ARE ATTACHED TO THE SHEAR BLOCK WITH 2 NO. 12 X 7/8" FHTF <br />SCREWS. CORNERS ARE SEALED WITH DOW 795 SILICONE SEALANT. <br />TYPICAL 90 DEGREE CORNER FRAMING: VERTICAL CORNER MEMBERS RUN <br />THROUGH WHILE THE HORIZONTAL MEMBERS ARE MITER CUT, BUTTED AND <br />MECHANICALLY FASTENED TO THE VERTICAL MEMBERS VIA A SHEAR BLOCK <br />(ITEM #15). THE SHEAR BLOCK IS MECHANICALLY FASTENED TO THE VERTICAL <br />CORNER FRAME MEMBERS WITH 3 NO. 12 X 7/16" PHTF SCREWS. THE <br />HORIZONTAL FRAME MEMBERS ARE ATTACHED TO THE SHEAR BLOCK WITH 2 <br />NO. 12 X 1/2" FHTF SCREWS. CORNERS ARE SEALED WITH DOW 795 <br />SILICONE SEALANT. <br />90 DEGREE CORNER FRAMING AT SPLICE JOINT LOCATIONS: VERTICAL CORNER <br />MEMBERS RUN THROUGH WHILE THE HORIZONTAL MEMBERS ARE MITER CUT, <br />BUTTED AND MECHANICALLY FASTENED TO THE VERTICAL MEMBERS VIA A <br />SHEAR BLOCK (ITEM #18). THE SHEAR BLOCK IS MECHANICALLY FASTENED TO <br />THE VERTICAL CORNER FRAME MEMBERS WITH 2 NO. 12 X 7/16" PHTF <br />SCREWS (2 PER SHEAR BLOCK), THE HORIZONTAL FRAME MEMBERS ARE <br />ATTACHED TO THE SHEAR BLOCK WITH 2 NO, 12 X 1/2" FHTF SCREWS (2 <br />PER SHEAR BLOCK). CORNERS ARE SEALED WITH DOW 795 SILICONE SEALANT. <br />STANDARD FRAMING AT SPLICE JOINT LOCATIONS: VERTICAL MEMBERS RUN <br />THROUGH WHILE THE HORIZONTAL MEMBERS ARE SQUARE CUT, BUTTED AND <br />MECHANICALLY FASTENED TO THE VERTICAL MEMBERS VIA A SHEAR BLOCK <br />(ITEM #17)_ THE SHEAR BLOCK IS MECHANICALLY FASTENED TO THE VERTICAL <br />CORNER FRAME MEMBERS WITH 2 NO. 12 X 1 7/8" PHTF SCREWS (2 PER <br />SHEAR BLOCK). THE HORIZONTAL FRAME MEMBERS ARE ATTACHED TO THE <br />SHEAR BLOCK WITH 2 NO. 12 X 1/2" FHTF SCREWS (2 PER SHEAR BLOCK). <br />CORNERS ARE SEALED WITH DOW 795 SILICONE SEALANT. <br />THESE I.G_ GLASS OPTIONS <br />ARE NOT APPLICABLE FOR <br />USE WITH A VERTICAL CORNER <br />FRAME MEMBER. I.G. GLASS <br />MAY ONLY BE APPLIED <br />BETWEEN INTERMEDIATE & <br />JAMB FRAME MEMBERS <br />(KAWNEER DOES NOT SUPPLY <br />A CORNER PRESSURE PLATE <br />FOR USE WITH I.G. GLASS) <br />GLASS D.LO. SIZE VS. PRESSURE <br />GLASS <br />OPTIONS <br />MAXIMUM <br />D.LO. <br />WIDTH <br />MAXIMUM <br />D.L.O. <br />HEIGHT <br />ALLOWABLE <br />DESIGN <br />PRESSURE <br />1, 2, 3 & 4 <br />58 1/2" <br />82 1/8" <br />+/-90 PSF <br />51 3/8" <br />93 1/2" <br />+/-90 PSF <br />50 5/8" <br />94 3/4" <br />+/-90 PSF <br />73 3/4" <br />54 5/8" <br />+/-90 PSF <br />1 & 2 <br />58 1/2" <br />93 1/2" <br />+/-65 PSF <br />57 3/4" <br />94 3/4" <br />+/-65 PSF <br />5 & 6 <br />58 1/2" <br />93 1/2" <br />+/-90 PSF <br />57 3/4" <br />94 3/4- <br />+/-90 PSF <br />73 3/4" <br />54 5/8" <br />+/-90 PSF <br />SEE GLAZING DETAILS FOR GLASS OPTIONS <br />HEIGHT & WIDTH MAY NOT BE INTERCHANGED! <br />RED. THEY MAY NOT BE USED FOR THE ASSEMBLY <br />)R INSTALLATION OF ANY OTHER PRODUCT NOR MAY <br />BE USED FOR RATIONAL AND/OR LOCAL APPRO/AL <br />N PRODUCT NOT PRODUCED BY THE MANUFACTURER <br />MAXIMUM ALLOWABLE FRAMING <br />MEMBER DEFLECTION <br />L/180 (SPAN OF MEMBER <br />DIVIDED BY 180) <br />NOTE: THIS IS THE MAXIMUM ALLOWABLE <br />DEFLECTION AS RESTRICTED BY THE <br />BUILDING CODE. IF JOB CONDITIONS <br />REQUIRE LESS DEFLECTION, THE JOB <br />CONDITIONS SHALL CONTROL. <br />ANCHOR LEGEND <br />ANCHOR <br />SYMBOL <br />ANCHOR <br />DESCRIPTION <br />® <br />STANDARD WIND LOAD ANCHOR <br />® <br />CORNER WIND LOAD ANCHOR <br />m <br />STANDARD DEAD LOAD ANCHOR <br />® <br />CORNER DEAD LOAD ANCHOR <br />STANDARD T-ANCHOR <br />CORNER T-ANCHOR <br />DOOR JAMB U-ANCHOR <br />A,IF-ANCHOR <br />(FRAME MEMBER ENDS) <br />SEE SHEETS 6-10 FOR DETAILS OF <br />ANCHORS <br />VERTICAL MEMBER REINFORCEMENT LEGEND <br />R1 = REINFORCEMENT PART NUMBER 36 <br />R2 = REINFORCEMENT PART NUMBER 36 & 37 <br />R3 = REINFORCEMENT PART NUMBERS 36, 37 & 38 <br />R4 = REINFORCEMENT PART NUMBERS 36, 37, 38 & 39 <br />RS = REINFORCEMENT PART NUMBER 40 <br />SEE PARTS DRAWINGS & PARTS LIST FOR APPLICABLE <br />REINFORCEMENT MEMBERS & THEIR DETAIL <br />EVALUATION OF THIS PRODUCT 5 BASED ON APPLICABLE STANDARDS <br />AND/OR INFORMATION & RESULTS FROM APPLICABLE TEST REPORTS - <br />THE FLORIDA BUILDING CODE VERSION CONSIDERED WITH THIS <br />EVALUATION WAS THAT IN FORCE AT THE TIME OF THE EVALUATION. IN <br />THE EAA:ITT OF CODE VERSION CHANGES/UPDATES OR IN THE EVENT <br />THAT NEW OR ADDITIONAL TESTING IS COMPLETED ON THIS PRODUCT, <br />PRIOR TO STATIt CODE COMPLIANCE WITH THE STATE, THE <br />MANUFAC URER SHALL CONFIRM WITH THE EVALUATION ENGINEER OF <br />RECORD THAT EVERYTHING SPECIFIED HERE -IN IS CURRENT WITH ALL <br />CURRENT TESTING, CODES AND APPUCABLE STANDARDS. <br />DOTE: INFORMATION ON THIS SHE <br />APPLIES TO ALL ELEVATIONS. <br />=3 <br />i <br />v <br />wm <br />o W4��i <br />a <br />Urn <br />.- <br />M ¢W¢H <br />n � voi z <br />� 3 coi <br />0 <br />03� <br />M\\\111111tf//� <br />�o <br />CI <br />bZ <br />w <br />ffQQ1\\ <br />SHEET NO. <br />1 OF 18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.