Laserfiche WebLink
1. WITH EACH APPLICABLE JOB, SHOP DRAWINGS SHALL BE PREPARED AND CERTIFIED BY A LICENSED ENGINEER EXPERIENCED WITH CURFAIN WALL DESIGN. <br />2. THE RESPONSIBLE ENGINEER SHALL DESIGN THE WALL SYSTEM SEPARATELY FOR EACH JOB & CONFIRM THAT ALL CONDITIONS STATED HERE -IN HAVE BEEN <br />CONSIDERED AND ADHERED TO IN THAT DESIGN. <br />& IN HIS/HER DESIGN, THE RESPONSIBLE ENGINEER SHALL VERIFY THE INTEGRITY OF ALL CONNECTIONS AND FRAMING MEMBERS & SHALL TAKE RILL RESPONSIBILITY <br />FOR THE INTEGRITY OF THE SYSTEM DESIGN AS A WHOLE WHILE NOT ALLOWING THE CONDITIONS STATED HERE -IN TO BE EXCEEDED. ALLOWABLE SUPPORT REACTIONS <br />AND VERTICAL FRAMING MEMBER BENDING MOMENTS SHALL NOT EXCEED THOSE STATED IN THE TABLES ON THIS SHEET, REGARDLESS OF JOB DESIGN <br />4. THE CURTAIN WALL DESIGN ENGINEER SHALL CONSIDER ALL APPLICABLE REACTION LOADS IN HIS/HER DESIGN WHILE NOT ALLOWING THE REACTIONS RESUTUNG FROM <br />WIND LOADS TO EXCEED THOSE SPECIFIED IN THE ANCHOR REACTION LOAD TABLE <br />S THE WORSE CASE OF THE CONDITIONS SPECIFIED IN THIS PRODUCT APPROVAL DRAWING AND THOSE DETERMINED BY THE INDIVIDUAL JOB ENGINEER'S ANALYSIS & <br />DESIGN SHALL CONTROL AS APPLICABLE FOR THE ACTUAL JOB, <br />IL REGARDLESS OF JOB DETERMINED MEMBER STRESS & DEFLECTION CONDITIONS, THE FOLLOWING SHALL APPLY: <br />A REINFORCEMENT TYPE R1 MUST BE PLACED BETWEEN SUPPORTS IN &L VERTICAL INTERMEDIATE FRAME MEMBERS THAT SPAN OVER 114" BETWEEN THEIR <br />SUPPORTS (NOT REQUIRED IF THE UNSUPPORTED SPAN IS 114" OR LESS & THE JOB DESIGN ALLOWS FOR NO REINFORCEMENT). <br />B. IF BETWEEN 2 DOOR UNITS, THE VERTKAL FRAMING MEMBER SHALL BE REINFORCED. REINFORCEMENT SHALL BEGIN MAXIMUM 12- UP FROM THE SILL & EXTEND <br />MINIMUM 12' PAST THE DOOR HEAD FRAME <br />C. ALL VERTICAL INTERMEDIATE FRAMING MEMBERS SHALL BE REINFORCED ACROSS ALL INTERMEDIATE DEAO/WIND LOAD ANCHOR LOCATIONS WITH ONE OF THE <br />REINFORCEMENT TYPES R7, R2 OR R3 AS SPECIFIED IN THE ELEVATION THIS REINFORCEMENT SHALL EXTEND A MINIMUM OF 18" ABOVE & BELOW THE <br />SUPPORT. <br />D: REINFORCEMENT TYPE R4 IS REQUIRED IN ALL VERTICAL CORNER FRAME MEMBERS. IT SHALL BE CONTINUOUS BETWEEN ALL MEMBER SPLICE JOINTS AND <br />EXTEND TO WITHIN 24" OF WALL BASE, 1Y OF A SPLICE & 18. OF THE WALL TOP. <br />7. REINFORCEMENT IS NOT REQUIRED TO BE CONTINUOUS TOP TO BOTTOM WITHIN THE VERTICAL FRAMING MEMBERS. REINFORCEMENT MAY BE NDN-CONTINUOUS, AS <br />DETERMINED FOR EACH JOB, PROVIDING IT MEETS THE MINIMUM GUIDELINES OF THIS DRAWING. <br />L THIS ELEVATION SHOWS THE 16DO CURTAIN WALL SYSTEM 1 IN A MULTI -STORY APPLICATION. THE NUMBER OF FLOORS WITH WHICH THIS SYSTEM MAY BE USED <br />RANGE FROM TWO(2) TO UNUMITED WITH THE ONLY RESTRICTIONS BEING THE MAXIMUM SPAN BETWEEN FLOORS/SUPPORTS AND THE MAXIMUM D.LO. SIZES SPECIFIED. <br />I. SPLICING OF VERTICAL FRAME MEMBERS MAY OCCUR BETWEEN SUPPORTS AS REQUIRED. LOCATION OF THOSE SPLICES SHALL BE WHERE A BENDING MOMENT OF <br />NEAR ZE100) EXISTS IN THE MEMBER <br />10. THE MULTI -SPAN ELEVATION SHOWN SHOWS ONE DOOR SECTION. MULTIPLE DOOR SECTIONS MAY OCCUR SIDE -BY SIDE IN ONE WALL SYSTEM PROVIDING ALL <br />REQUIREMENTS WITHIN THIS DRAWING ARE MET AND THE JOB DESIGN ALLOWS FOR THE MULTIPLE DOOR CONDITION. <br />11. ALTHOUGH A DOOR SECTION IS SHOWN, THAT SECTION MAY EXIST WITH OR WITHOUT A DOOR. <br />12. THE ELEVATION HERE -IN STOWS T-ANCHORS AT THE BASE OF THE WALL ONLY. THESE ANCHORS MAY ALSO BE USED AT THE TOP OF A WALL IN UEU OF THE <br />WIND/DEAD LOAD ANCHORS SHOWN PROVIDING THE SPAN BETWEEN THE T-ANCHORS AND THE BELOW WIND/DEAD LOAD ANCHORS DOES NOT EXCEED 167 1/2" (SAME <br />SPAN AS AT THE BASE) & THEY ARE INSTALLED THE SAME AS SHOWN AT THE BASE T-ANCHORS MAY APPLY AT THE TOP END OF A DOOR JAMB FRAME MEMBER. <br />(1) MAXIMUM ALLOWABLE BENDING MOMENTS IN <br />VERTICAL FRAMING MEMBERS <br />(FOR USE WITH MULTI -SPAN CURTAIN WALL) <br />(2) <br />(3) MAXIMUM <br />VERTICAL MEMBER <br />ALLOWABLE <br />BENDING MOMENT <br />(POS & NEG) <br />INTERMEDIATE MEMBER WITH NO REINFORCEMENT <br />61934 IN -LB <br />INTERMEDIATE MEMBER WITH REINFORCEMENT 'R1' <br />84610 IN -LB <br />INTERMEDIATE MEMBER WITH REINFORCEMENT "R2" <br />115852 IN -LB <br />INTERMEDIATE MEMBER WITH REINFORCEMENT "R3" <br />133705 IN -LB <br />INTERMEDIATE MEMBER WITH REINFORCEMENT 'R4" <br />150418 IN -LB <br />CORNER MEMBER WITH REINFORCEMENT "R5" <br />4)141377 IN -LB <br />NOTES: <br />(1) THE VALUES IS THIS TABLE ARE APPLICABLE TO THE JOB <br />REQUIRED DESIGN OF THE MULTI -SPAN WALL SYSTEM & NEED NOT <br />BE CONSIDERED WITH SINGLE SPAN WALLS. ALL SINGLE SPAN <br />MEMBER & REINFORCEMENT CONDITIONS SHALL BE AS SPECIFICALLY <br />SPECIFIED IN THE SINGLE SPAN ELEVATIONS. <br />(2) FOR DESCRIPTIONS OF REINFORCEMENTS, SEE THE "VERTICAL <br />MEMBER REINFORCEMENT LEGEND'. <br />(3) ALL VALUES ARE BASED ON THE WORSE CASE OF TESTED <br />MOMENT AND ALLOWABLE MOMENT. <br />(4) MOMENT VALUE SHOWN FOR THE CORNER MULLION IS DUE TO <br />THE RESULTANT LOAD IN THE PLANE OF THE MULLION (LOAD FROM <br />BOTH SIDES COMBINED INTO A RESULTANT). FOR SINGLE SIDE <br />LOAD, THE ALLOWABLE MOMENT SHALL NOT EXCEED 70688 IN -LB. <br />IN THAT DIRECTION (LOAD VECTOR 45 DEGREES TO MULLION <br />ANGLE). <br />ANCHOR REACTION LOAD <br />CAPACITY <br />(MULTI -SPAN CURTAIN WALL) <br />ANCHOR <br />ANCHOR <br />(1)MAXIMUM <br />SYMBOL <br />DESCRIPTION <br />ALLOWABLE <br />REACTION LOAD <br />ES <br />ISTANDARD WIND LOAD ANCHOR <br />8980 LBS <br />® <br />CORNER WIND LOAD ANCHOR <br />(2) 5967 LBS <br />m <br />STANDARD DEAD LOAD ANCHOR <br />8980 LBS <br />® <br />CORNER DEAD LOAD ANCHOR <br />(2) 5967 LBS <br />STANDARD T-ANCHOR <br />3152 LBS <br />CORNER T-ANCHOR <br />(2) 1789 LBS <br />DOOR JAMB U-ANCHOR <br />2694 LBS <br />MilIF-ANCHOR <br />(FRAME MEMBER ENDS) <br />1131 LBS <br />(1) MAXIMUM ALLOWABLE REACTION LOADS SHOWN <br />CONSIDER REACTIONS FROM WIND LOADS ONLY & APPLY <br />TO BOTH POSITIVE & NEGATIVE WIND DIRECTIONS. IN <br />ADDITION TO WIND LOADS, THE CURTAIN WALL DESIGN <br />ENGINEER OF RECORD FOR EACH PROJECT SHALL ALSO <br />CONSIDER OTHER APPLICABLE LOADS SUCH AS, BUT <br />POSSIBLY NOT LIMITED TO, DEAD LOADS FROM THE <br />CURTAIN WALL WEIGHT. <br />(2) REACTION LOAD SHOWN FOR THE CORNER ANCHORS <br />IS THE RESULTANT LOAD IN THE PLANE OF THE MULLION <br />(LOAD FROM BOTH SIDES COMBINED INTO A RESULTANT). <br />FOR EITHER SIDE LOAD, THE ALLOWABLE REACTION LOAD <br />SHALL NOT EXCEED 4220 LB. FROM EITHER SIDE FOR <br />THE WIND & DEAD LOAD ANCHORS NOR 1265 LBS FROM <br />EITHER SIDE FOR THE T-ANCHOR. <br />OPENING TYPE FRAME/CUP TO OPENING MINIMUM MINIMUM I[ —,- <br />(SUBSTRATE) I FASTENER TYPE I EMBED EDGE DIST. IM <br />F-PERIMETER ANCHOR SCREWS 11RI <br />MIN. 1/8' THK <br />I MIN. 3000 PSI CONCRETE 1 (1) 3/8" CONCRETE SCREW ANCHOR 12 1/2" 1 2 1/2" II <br />3/8"-16 430 SS HCMS OR GR. 5 CS THREAD FULL 3/4- <br />FORMING SCREW <br />3/8- GR. 5 CS OR 316 SS BOLT WITH LOCK FULL 3/4- <br />MIN. 1/4' THK A36 STEEL WASHER & NUT <br />1/2'-13 300 SS HCMS OR GR. 5 CS THREAD FULL 1. <br />FORMING SCREW <br />1/2" GR. 5 CS OR 316 SS BOLT WITH LOCK FULL 1" <br />WASHER & NUT <br />(1) 3/8" & 1/2" CONCRETE SCREWS SHALL BE SIMPSON STRONG -TIE TITAN HD SCREW ANCHOR <br />(GALVANVED STEEL). <br />(2) MINIMUM CONCRETE SLAB THICKNESS FOR PLACEMENT OF 'T' & "U' ANCHORS IS 7'. <br />MAXIMUM ALLOWABLE DESIGN PRESSURE <br />(MULTI -SPAN CURTAIN WALL) <br />..Lan -On DCG <br />WNABLE GLASS DESIGN PRESSURE TABLE ON SHEET 1 <br />PRESSURE RESD8C110NS THE LESSER OF THE <br />PRESSURE ON THE FRAMING SYSTEM AND THAT OF THE <br />dU N <br />2 <br />z0 m <br />(/1 <br />L) <br />a <br />NINFORMATION ON <br />OTE: <br />THIS SHEET APPLIES TO <br />s <br />ELEVATIONS ON SHEET 3 <br />a <br />w.OR <br />ONLY. <br />U�mz <br />3); o <br />OPTION 1: USE THE TECHNICAL INFORMATION SPECIFIED ON THIS <br />SHEET FOR AN EXACT APPROACH TO DESIGN THE CURTAIN WALL <br />FRAMING WHILE BEING REQUIRED TO PROVIDE ENGINEER SIGNED <br />AND SEALED JOB SPECIFIC SHOP DRAWINGS FOR EACH JOB. <br />OPTION 2: USE THE LOAD TABLES ISSUED WITHIN W. W. SCHAEFER <br />ENGINEERING & CONSULTING, PA.'S ADDENDUM W TO <br />CONSERVATIVELY DETERMINE THE REQUIREMENTS FOR THE CURTAIN <br />WALL FRAMING. WITH THIS OPTION, SIGNED AND SEALED JOB <br />SPECIFIC SHOP DRAWINGS ARE NOT A REQUIREMENT OF THIS <br />APPROVAL. <br />0 <br />m <br />w <br />c <br />n <br />11 <br />OF <br />