My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
360 S Rosemary Ave Ste 400 (2)
Zephyrhills
>
Building Department
>
Building Plans
>
360 S Rosemary Ave Ste 400 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 11:25:50 AM
Creation date
2/27/2025 11:14:47 AM
Metadata
Fields
Template:
Building Plans
Street #
360
Location
S Rosemary Ave Ste 400
Contractor
Superior Fire Alarm
Building Plans - Permit #
5454-5455
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(E)POTTER AFC-goo <br />The Symbol of Protection Fire Alarm Control Panel <br />SLC Loop Accessories <br />The control panel may be connected with up to 100 addressable devices or modules in any combination. The SLC is not restricted by any special wire <br />requirements and may be wired with anti wire that complies with the NEC. <br />SLC Loop Devices <br />Device <br />Description <br />PADI00-PD <br />Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. <br />PAD100-PHD <br />Combination Analog Photo Electric Smoke/Heat Detector— a smoke detector with a listed obscuration of 1.02 to 3.83 percent <br />obscuration and a fixed temperature 135' Fahrenheit heat detector. <br />PADI00-HD <br />Analog Fixed (1 35d-185dF) or Rate -of -Rise Heat Detector (software selectable) <br />PAD 100-DUCTR <br />Addressable Duct Smoke Detector witli Form C Relay. Addressable Duct Smoke Detector with Form C relay rated at 10a �cr <br />250/120VAC or 8annps at 301o'DC. <br />PAD100-DUCT <br />Addressable Duct Smoke Detector. <br />PAD100-6B <br />G- round base that is mouthed to an electrical box and wired for connection of one of the above sensors. <br />PAD1004B <br />4" round base that may be mounted to an electrical box and wired for connection to the above sensors. <br />PAD100-I13 <br />Isolator base that interrupts a short in a SEC and prevents the short from affecting protected devices on the loop. <br />PAD100-RB <br />Addressable Rclay Base that contains one relay controlled by the SI_C. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. <br />PADl00-SB <br />Addressable S0U11&i Base that contains an addressable sounder module that may be configured for local, group and all call. <br />PADI00-CD <br />Addressable CO gas detector. <br />PAD100-DD <br />Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. <br />PAD100-LFSB <br />Addressable Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local, group and all <br />call. The LFSB complies xNith the Low Frequency Signal Requirements (520 Hz) <br />PAD100-SPKB <br />Speaker base is a Nall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W. <br />Modules <br />Device <br />Description <br />PAD100-MIM <br />Micro Input Module provides a small foot print contact module for mounting inside an enclosure. <br />PAD100-PSSA <br />Single Action Addressable Pull Station. <br />PAD100-PSDA <br />Dual Action Addressable Pull Station. <br />PAD100-SIM <br />Single Input Modulc is a standard contact module v ith an LED that mounts into a 4" square electrical box. <br />PAD100-DIM <br />Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. <br />PAD100-TRI'1 <br />Two Relay Two Input module provides t\vo form C relays that are individually controlled by the control panel. Each relay is rated for 2 <br />amps at 30VDC or 0.5 amps at 125%AC. Also provides two contact inputs. <br />PAD100-NAC <br />Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. <br />PAD100-ZM <br />Zone Module is used to connect conventional 2-wire smoke detectors to the system. <br />PAD100-IM <br />Isolator Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. <br />PADI00-RM <br />Relav Module that provides one f,;rm C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. <br />PAD100-LED <br />Module provides a single addressable LLD that is controlled by the control panel. <br />PAD100-SM <br />Speaker Module provides snitching for txNo audio channels. <br />PAD100-LEDK <br />Addressable LED and key s\ itch that mounts in a single gang box. <br />PAD100-DRTS <br />DUCTR Remote "Ilst Snitch that mouths in a single gang box and optionally supervised. For use with the PAD100-DUCTR only. <br />PAD100-0R01 <br />One Relay One Input Nlodule provides one fomn C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. <br />Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br />_ <br />8830114-REV [ 9'19 PAGE 2OF4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.