My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7344 Gall Blvd (4)
Zephyrhills
>
Building Department
>
Building Plans
>
7344 Gall Blvd (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 5:27:15 PM
Creation date
2/25/2025 9:35:46 AM
Metadata
Fields
Template:
Building Plans
Street #
7344
Location
Gall Blvd
Contractor
Intrastruct Tampa
Building Plans - Permit #
21056
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section <br /># <br />Mechanical Rough -In Inspection <br />Complies? <br />Comments/Assumptions <br />& Req.ID <br />C403.2.13 <br />Unenclosed spaces that are heated <br />,❑Complies <br />Exception: Requirement does not apply. <br />[ME71]2 <br />use only radiant heat. <br />❑Does Not <br />!❑Not Observable <br />❑Not Applicable <br />C403.2.3 <br />HVAC equipment efficiency verified.❑Complies <br />See the Mechanical Systems list for values. <br />[ME55]2 <br />❑Does Not <br />❑Not Observable <br />❑Not Applicable <br />C403.2.9. <br />Ducts, air handlers, filter boxes, <br />❑Complies <br />Requirement will be met. <br />3' <br />building cavities, mechanical closets <br />❑Does Not <br />[ME10]2 <br />and enclosed support platforms that <br />❑Not Observable <br />form the primary air containment <br />❑Not Applicable <br />passageways for air distribution <br />systems are sealed in accordance with <br />the applicable criteria of this section <br />and Table C403.2.9.2. <br />C403.2.9. ,Cavities <br />in framed spaces are not <br />❑Complies <br />Exception: Requirement does not apply. <br />4 <br />used to deliver air from or return air to❑Does <br />Not <br />[ME78]2 <br />the conditioning system unless they <br />Observable <br />contain an air duct insert which is �RNot <br />❑Not Applicable <br />insulated in accordance with Section <br />C403.2.9.1 and constructed and <br />sealed in accordance with the <br />requirements of Section C403.2.9.2 <br />appropriate for the duct materials <br />;used. <br />C403.2.9. !Air <br />distribution systems are sized and <br />❑Complies <br />Requirement will be met. <br />5 <br />designed in accordance with <br />❑Does Not <br />[ME76]2 <br />recognized engineering standards. <br />❑Not Observable <br />Refer to section details. <br />❑Not Applicable <br />C403.2.9. IAir-handling <br />units not installed in <br />❑Complies <br />Exception: Requirement does not apply. <br />6 <br />attics of commercial buildings. <br />❑Does Not <br />[ME77]2 <br />;❑Not <br />Observable <br />❑Not Applicable <br />C403.2.4. :Zone <br />isolation devices and controls <br />❑Complies <br />Exception: Exhaust and outdoor air connections having fan <br />4 1 <br />installed where applicable. <br />❑Does Not <br />systems 5000 cfm or smaller. <br />[ME112]3 <br />❑Not Observable <br />❑Not Applicable <br />C403.2.4. <br />Fault detection and diagnostics ❑Complies <br />Requirement will be met. <br />7 !installed <br />with air-cooled unitary DX ❑Does Not <br />[ME113]2 <br />units having economizers. <br />,[:]Not Observable <br />❑Not Applicable <br />C408.2.2. <br />Air system balancing accomplished in ❑Complies <br />Requirement will be met. <br />1 <br />a manner to first minimize throttling ❑Does Not <br />[ME53]3 <br />losses, then for fans with fan system <br />❑Not Observable <br />power greater than 1 hp, fan speeds <br />shall be adjusted to meet design flow ❑Not Applicable <br />conditions. Balancing procedures shall <br />be in accordance with NEBB <br />Procedural Standards, the AABC, <br />National Standards, or equivalent <br />procedures. <br />C403.2.6. <br />Demand control ventilation provided ❑Complies <br />Requirement will be met. <br />1 for spaces >500 ft2 and >25 ❑Does Not <br />[ME59]1 <br />people/1000 ft2 occupant density and <br />❑Not Observable <br />served by systems with air side <br />Applicable <br />economizer, auto modulating outside❑Not <br />air damper control, or design airflow <br />>3,000 cfm. <br />111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) <br />Project Title: BLOX - Zephyrhills Report date: 11/23/20 <br />Data filename: P:\CLNT\Retail G\07 Project Manual\COMcheck\Zephyrhills COMCheck-2020.11.13.cck Page 22 of 37 <br />