My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6627 Fort King Rd (4)
Zephyrhills
>
Building Department
>
Building Plans
>
6627 Fort King Rd (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 5:02:45 PM
Creation date
2/25/2025 12:50:59 PM
Metadata
Fields
Template:
Building Plans
Street #
6627
Location
Fort King Rd
Contractor
Superior Fire Alarm
Building Plans - Permit #
17471
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Gamewell <br />FIRE CONTROL <br />INSTRUMENTS <br />by Honeywell <br />Description <br />The Gamewell-FCI Velociti® Series addressable output <br />supervised control module (AOM-2SF) allows a <br />Gamewell-FCI analog addressable fire alarm control panel <br />to switch an external power supply, such as a DC supply or <br />audio amplifier (up to 80 VRMs) to notification appliances. <br />The AOM-2SF notification appliance circuit can be wired <br />either Class A (Style Z) or Class B (Style Y). It also super- <br />vises the wiring to the connected loads and reports their <br />status to the panel as NORMAL, OPEN or SHORT <br />CIRCUIT. The module contains a panel controlled LED. <br />The Velociti® Series use a communication protocol that <br />substantially increases the speed of communication <br />between the SLC devices and certain Gamewell-FCI ana- <br />log addressable fire alarm control panels. These devices <br />operate in a grouped fashion. If one of the devices in the <br />group has a status change, the panel's microprocessor <br />stops the group poll and concentrates on the single device. <br />The net result is a superior response speed up to five <br />times greater than the earlier designs. <br />The AOM-2SF module is designed for installation in the <br />signaling line circuit of any Gamewell-FCI analog address- <br />able fire alarm control panel. The signaling line circuits of <br />Gamewell-FCI analog addressable fire alarm control pan- <br />els are designed to accommodate up to 159 modules per <br />circuit. The AOM-2SF is designed to mount in a 4" (10.16 <br />cm) square junction box 2 1/8" (5.5 cm) deep. <br />Table 1 lists the relay contact ratings. <br />Current <br />Rating <br />Maximum <br />Voltage <br />Load <br />Description <br />Application <br />3A <br />30 VDC <br />Resistive <br />Non -Coded <br />2A <br />30 VDC <br />Resistive <br />Coded <br />0.9A <br />110 VDC <br />Resistive <br />Non -Coded <br />0.5A <br />125 VAC <br />Resistive <br />Non -Coded <br />0.5A <br />30 VDC <br />Inductive (UR=5ms) <br />Coded <br />1A <br />30 VDC <br />Inductive (L/R=2ms) <br />Coded <br />0.5A <br />125 VAC <br />Inductive (PF=.35) <br />Non -Coded <br />0.7A <br />75 VAC <br />Inductive <br />Non -Coded <br />Table 1: Relay Contact Ratings <br />Velociti® is a registered trademark of Honeywell International Inc. <br />UL® is a registered trademark of Underwriters Laboratories Inc. <br />VelocitiO Series <br />A8111=2SF <br />Addressable Output Relay <br />Supervised Control Module <br />AOM-2SF <br />Features <br />• Listed under ULO Standard 864 and UL2572 for Mass <br />Notification. <br />• Designed as a compact size to allow easy installation. <br />• Includes Class A, Style Z, or Class B, Style Y notification <br />appliance circuit. <br />• Accommodates audio amplifiers up to 80 VRMs. <br />• FM Listed as suitable for a releasing device service. <br />• Includes a bicolor LED that flashes green whenever the <br />module is addressed, and lights steady red upon <br />activation. <br />*Note: Only the red LED is operative in panels that do not operate in <br />Velociti® mode. <br />Specifications <br />Supervisory Current: <br />Alarm Current: <br />Operating Temperature <br />Relative Humidity: <br />Dimensions <br />.000375 amps <br />.0065 amps <br />32' to 120' F (0' to 49' C) <br />10 to 93% relative humidity <br />(non -condensing) <br />4 1/2" H x 4" W x 1 1/4" D <br />(11A H x 10.2 W x 3.2 D cm) <br />Ordering Information <br />Part Number <br />Description <br />AOM-2SF <br />Addressable output supervised <br />control module <br />SIGNALING <br />&L <br />FM <br />MEA <br />LISTED moo. <br />APProv, <br />S1949 3023594 227-03•EVoI.IV 7300-1703:0102 <br />I IS090011 GAMEWELL-FCI <br />12 Clintonville Road, Northford, CT 06472-1610 USA - Tel: (203) 484-7161 • Fax: (203) 484-7118 <br />Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. <br />©2014Honeywelllntemationallnc. Allrghtsreserved. www.gamewell-fci.com 9020-0627 Rev. G page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.