<br />ZONE DESIGN HEATING LOAD SUMMARY <br />,Location Tampa., Florida 02-02-93 <br />Prepared By ADVANCED TECH. DESIGN 6022890201 <br />Carrier Hourly Analysis Program Page 1 of 1 <br />************************************************************************ <br />CALCULATION DATA: <br />Zone Name: ',RESIDENCE Calc Time: Winter design <br />Job Name RESID.LOAD FOR GENE CLEM Amb db 36.0 F <br />************************************************************************ <br /> <br />LOAD COMPONENT <br /> <br />LOAD (BTU/hr) <br /> <br />WALL TRANSMISSION <br />ROOF TRANSMISSION <br />GLASS TRANSMISSION <br />TRANSMISSION LOSS TO UNCOND. SPACES <br />INFILTRATION LOSS <br />SLAB FLOOR <br />HEATING, SAFETY BTU/hr <br /> <br />6,022 <br />3,706 <br />11,068 <br />1,188 <br />o <br />5,112 <br />13,'548 <br /> <br />SUB-TOTAL <br />NET VENTILATION LOSS <br /> <br />40,643 <br />3,455 <br /> <br />TOTAL HEATING LOAD <br /> <br />44,098 <br /> <br />941 CFM <br />110.0 deg F <br />94 CFM <br />70.0 deg F <br /> <br />HEATING SUPPLY CFM <br />HEATING SUPPLY AIR TEMPERATURE <br />HEATING VENTILATION AIR CFM <br />HEATING THERMOSTAT SETPOINT TEMP <br /> <br />************************************************************************ <br />