<br />SUMMER POINT IVIULTIPLlERS (SPM) <br /> <br />6A-1 SUMMER OVERHANG FACTORS ISOFl FOR SINGLE AND DOUBLE PANE GLASS, <br />in r _ OH~).TIO ,00-,11 ,12-,17 .18-,26 .27-.35 .36-.46 ,47-.57 ,58-,70 .71-.83 <br />, N 1,00 ,94 ,91 ,87 .83 ,79 ,76 ,72 <br />NE/NW 1,00 ,94 ,91 ,85 ,79 ,72 ,68 ,63 <br />t; II: EIW 1,00 ,95 ,92 ,85 .78 .70 .64 ,58 <br />~ lO SE/SW 1,00 ,93 ,90 ,81 .72 ,62 .55 ,49 <br />S 1,00 ,91 .87 .77 .67 ,57 ,50 ,45 <br />nl-ll I=Nr.TI-l' nit 1 It 1'/, It 2 It 3 It, ::1'/, It li1j, It <;'/, It <br />'To select bv Ovemano Lenoth no oart of olass shall be more than 8 ft, below the ovemane, <br /> <br />6A-2 WALL SUMMER POINT MULTIPLIERS SPM <br />FRAME <br /> <br /> <br />CONCRETE BLOCKl <br />INT,INSULATlON <br />NORMAL WT. <br />EXT ADJ <br />2,5 .9 <br />1,4 .7 <br />1,0 ,6 <br />,8 ,4 <br />.4 ,3 <br />,2 ,2 <br />.1 ,1 <br /> <br />R-V ALUE <br />0-6,9 <br />7-10,9 <br />11-12,9 <br />13-18,9 <br />19-25,9 <br />26& U <br /> <br />WOOD <br />EXT ADJ <br />6.4 2,2 <br />2.3 ,8 <br />1,9 ,7 <br />1,7 .6 <br />1,0 ,3 <br />,6 .2 <br /> <br />STEEL <br />EXT ADJ <br />8.9 2,9 <br />4,1 1,3 <br />3,0 1,0 <br />2,8 0,9 <br />2.4 0,8 <br />1,3 0,4 <br /> <br />SPM) <br /> <br /> CLIMATE ZONES 4 5 6 <br />.84-1.18 1,19-1.72 1,73-2.73 2.74+ <br />,69 .63 ,56 .50 <br />,58 ,50 ,40 ,36 <br />,52 ,42 ,33 .26 <br />.42 .33 ,27 .22 <br />,39 ,32 .28 ,25 <br />fl1j,1t 91j,1t 14ft. ?nlt... <br /> <br /> <br />6A-3 DOOR SUMMER POINT MULTIPLIERS 6A-4 CEILING SUMMER POINT MULTIPLIERS lSPMl <br />DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOFING <br /> R-V ALUE SPM R-VALUE SPM CEILING TYPE <br />WOOD 7,2 2,4 19-219 1,1 10-10,9 3,0 R-V ALUE DROPPED EXPOSED <br /> 22-25.9 ,9 11-12,9 2,7 10-1:3.9 3,0 3,3 <br />INSULATED 4,8 1,6 26-29,9 ,7 13-18,9 2.4 14-20,9 2,0 2,1 <br /> 30-37,9 ,6 19-25,9 1.8 21 & Uo 1.4 1.3 <br /> 38 & Uo ,4 26-29,9 1,1 <br /> ::In R. Iln nq <br />6A-5 FLOOR SUMMER POINT MULTIPLIERS ISPMl <br />SLAB-ON-GRADE RAISED RAISED WOOD2 <br /> POST OR PIER STEM WALL wi UNDER <br />EDGE INSULATION CONCRETE < CONSTRUCTION FLOOR INSULATION ADJACENT <br />R-V ALUE SPM R-V ALUE SPM ...... R-V ALUE SPM SPM SPM <br />0-2,9 -31,9 0-2.9 -1.0 0-6,9 0,9 N/A 5,3 <br />3-4,9 -31,8 / 3-4,9 -1,7 7-10,9 -1,1 ,2,8 2,1 <br />5-6,9 -31,7 ...... 5-6,9 -1,7 11-18,9 -1,0 .2,2 1.8 <br />7 R. Iln -::11 fl 7 R. Iln -17 19 R. lJn J1Q ..1 R 1 n <br /> <br />6A-6 INFILTRATION SUMMER POINT MULTIPLIERS (SPM) <br />INFILTRATION PRACTICE SPM <br />SEE TABLE 9P <br />PRACTICE #1 13,8 <br />PRACTICE #2 10,9 <br /> <br />6A-7 DUCT MULTIPLIERS OM <br /> <br />SUPPLY DUCTS IN <br />UNCONDITIONED SPACE <br /> <br />SUPPLY DUCTS IN <br />ONDITIONED SPACE3 <br /> <br />R-V ALUE <br />4,2-5,9 <br />6,0-6,6 <br />6,7 & U <br />4.2-5.9 <br />6.0-6,6 <br />7 <br /> <br />RETURN DUCTS <br />IN UNCONDITIONED SPACE <br />1,14 <br />1,10 <br />1,09 <br />1,10 <br />1,07 <br />1. <br /> <br />RETURN DUCTS <br />IN CONDITIONED SPACE <br />1,10 <br />1,07 <br />1.06 <br />1.00 <br />1,00 <br /> <br />6A-8 COOLING SYSTEM MULTIPLIERS lCSMl <br />SYSTEM TYPE COOLING SYSTEM MULTIPLIERS ICSMI <br />Central Units (SEER) Ratina 7,5-7,9 8.0-8.4 8.5-8,8 8,9-9.4 9.5-9,9 10,0-10,4 10,5-10,9 11,0-11.4 11,5-11.9 12,0-12.4 <br />CSM .45 .43 ,40 ,38 ,36 .34 ,32 ,31 ,30 ,28 <br />PTAC & Room Uni1s (EER) Ratina 12,5-12.9 13,0-13.4 13,5-13,9 14,0-14.4 14,5-14.9 15,0-15.4 15,5-15,9 16,0-16.4 16.5-16,9 17.0-17.4 17.5 & Uo <br />CSM ,27 ,26 ,25 .24 ,24 ,23 .22 ,21 ,21 ,20 ,19 <br />MINIMUMS: CENTRAL UNITS-AIR COOLED SPLIT SYSTEM 10,0 SEER, SINGLE PKG, 9,7 SEER, GROUND WATER COOLED 11.0 EER. PTAG-SEE TABLE 6-3, <br /> <br />6A-9 HOT WATER MULTIPLIERS IHWMI <br />SYSTEM TYPE HOT WATER MULTIPLIERS IHWM <br />Electric Resistance EF ,80-.81 ,82-,83 ,84-,85 ,86-,87 ,88-,90 ,91-.93 ,94-,96 .97 & Uo <br /> HWM 4183 4081 3984 3891 3803 3678 3560 3450 <br />Natural Gas EF .43-.47 ,48-.49 I ,50,51 ,52-,53 ,54-,55 ,56-,57 ,58-,59 ,60-,61 ,62-,63 ,64-,65 ,66 & Un <br /> HWM 3098 2775 I 2664 2562 2467 2379 2297 2220 2138 2081 2018 <br />Lp Gas HWM 4195 3758 I 3608 3469 3340 3221 3110 3007 2910 2819 2733 <br />Solar EF 1,0-1.9 2.0-2.9 3,0-3,9 4,0-4,9 5,0 & Un <br />I-lWM R.4 Ii? ?II ?1 1<; <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2,1 OF APPENDIX C, 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3,1 OF APPENDIX C, 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION, <br /> <br />-3- <br />