Laserfiche WebLink
<br />WINTER POINT MULTIPLIERS (WPM) <br /> <br />CLIMATE ZONES +,,' 56 <br /> <br />6A.10 WINTER OVERHANG FACTORS (WOFl . <br />J OH RATIO I .00-,11 I ,12-,17 .18-.26 I ,27-,35 I .36-.46 I .47-,57 ,58-.70 ,71-.83 ,84-1.18 11.19-1,7211.7:3-2,731 2.74+ <br /> SINGLE PANE GLASS ~ <br />N 1.00 1.03 1.05 1.08 1.10 1,13 1.15 1.18 1.20 1,24 1.29 1.34 <br />NE/NW 1.00 1.07 1.10 1.15 1.20 1.25 1.30 1.35 1.39 1.50 1.59 1,67 <br />EIW 1.00 ,71 ,57 .19 -.20 -,65 -1.05 -1,48 -2.03 -3.01 -4,06 -5,04 <br />SE/SW 1.00 ,93 ,90 .80 ,68 .54 .39 ,22 .05 -,33 -.71 -1.01 <br />l- S 1.00 ,95 ,92 ,83 .70 .54 .36 ,13 -.13 -,70 -,98 -1,09 <br />ua: <br />~[ DOUBLE PANE GLASS <br />N 1.00 1,05 1,07 1.11 1.14 1.18 1.21 1.24 1.28 1,34 1.40 1.47 <br />NE/NW 1.00 1,11 1,16 1.24 1.32 1.41 1.48 1.56 1,63 1.80 1.94 2.08 <br />EIW 1.00 ,88 ,82 ,66 .50 ,31 ,15 -,03 -,26 -.66 -1,10 -1,50 <br />SE/SW 1.00 ,95 ,92 ,85 ,76 ,65 ,54 ,41 ,28 -,01 -.30 -,52 <br />S 1.00 ,96 ,94 ,87 .78 ,65 ,51 ,33 ,13 -.30 -,51 -.60 <br />OH LENGTH' Oft, 1 ft, 1% ft. 2ft, 3ft, 3% ft, 4%ft, 5% ft, 6% ft, 9V,ft, 14ft, 20ft,+ <br /> 'TO SELECT BY OVERHANG LENGTH, NO PART OF GLASS SHALL BE MORE THAN 8 FT, BELOW THE OVERHANG, <br /> <br />6A-11 WALL WINTER POINT MULTIPLIERS WPM <br /> <br />FRAME <br /> <br />WOOD <br />EXT ADJ <br />6.8 5,3 <br />2.5 2,1 <br />2,0 1,8 <br />1.8 1.6 <br />1.1 1. 0 <br />,7 ,7 <br /> <br />R.V ALUE <br />0-6,9 <br />7-10,9 <br />11-12.9 <br />13-18,9 <br />19-25,9 <br />26& U <br /> <br />STEEL <br />EXT ADJ <br />9.4 6,7 <br />4.4 3,3 <br />3.3 2,6 <br />3,0 2.4 <br />2,6 2.2 <br />1,4 1,2 <br /> <br /> <br />CONCRETE BLOCK' <br />INT. INSULATION EXT,INSUL <br />NORMAL WT. NOR. WT, <br />EXT ADJ EXT <br />6,0 3,1 6.0 <br />3,8 2,3 2,8 <br />2,9 1,9 2,0 <br />2,3 1,5 1,5 <br />1,5 1.1 ,8 <br />,8 ,7 <br />,5 ,5 <br /> <br /> <br />6A-12 DOOR WINTER POINT MULTIPLIERS 6A-13 CEILING WINTER POINT MULTIPLIERS (WPMl <br />DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOFING <br /> R.VALUE WPM R.VALUE WPM CEILING TYPE <br />WOOD 7.6 5,9 19-219 1.0 10-10,9 1.8 R-VALUE DROPPED EXPOSED <br /> 22-25.9 ,9 11-12.9 1,6 10-13,9 1.2 1,3 <br />INSULATED 5,1 4.0 26-29,9 .7 13-18,9 1,5 14.20,9 ,7 ,7 <br /> 30-37,9 ,6 19-25,9 1,1 21 & Un ,4 ,3 <br /> 38 & Uo .4 26-29,9 ,6 <br /> ::!n Ro Iln 4 <br />6A-14 FLOOR WINTER POINT MULTIPLIERS IWPM\ <br />SLAB-QN-GRADE T RAISED RAISED WOOQ2 <br />EDGE INSULATION CONCRETE POST OR PIER STEM WALL wi UNDER ADJACENT <br /> CONSTRUCTION FLOOR INSULATION <br />R-VALUE WPM :"ii R-VALUE WPM ... R-VALUE WPM WPM WPM <br />0-2,9 2.5 tt 0-2,9 4,0 0-6,9 7,9 N/A 5.3 <br />3-4.9 -1,7 3-4,9 1.8 ii 7-10.9 2.1 ,7 2.1 <br />5-6,9 -2,4 !i 5-6.9 1,1 HH 11-18.9 1.5 .5 1.8 <br />7 Rolin --;)7 Iii 7 Rolln R ... 19 Ro Iln9 1 1 n <br /> <br />WPM) <br /> <br />6A-15 INFILTRATION WINTER POINT MULTIPLIERS (WPM) 6A-16 DUCT MULTIPLIERS OM <br /> <br />SUPPLY DUCTS IN <br />CONDITIONED SPACE' <br /> <br /> <br />RETURN DUCTS <br />IN UNCONDITIONED SPACE <br />1.14 <br />1,10 <br />1.09 <br />1,10 <br />1,07 <br /> <br />RETURN DUCTS <br />IN CONDITIONED SPACE <br />1.10 <br />1.07 <br />1,06 <br />1.00 <br />1.00 <br /> <br />INFILTRATION PRACTICE WPM <br />(SEE TABLE 9P\ <br />PRACTICE #1 6.2 <br />PRACTICE #2 4,1 <br />II::! ?? <br /> <br />SUPPLY DUCTS IN <br />UNCONDITIONED SPACE <br /> <br />6A-17 HEATING SYSTEM MULTIPLIERS IHSM\ <br />SYSTEM TYPE HEATING SYSTEM MULTIPLIERS IHSMl <br />Central Heat HSPF 6,40-6.79 6.80-6,89 6,90-7.39 7.40-7,89 7,90-8.39 8.40-8.89 8,9-9,39 9.4-9,89 <br />Pump Units HSM .53 .50 ,49 .46 .43 .41 .38 .36 <br /> HSPF 9,90-10.39 10,40-10.89 10,90-11,39 11.40-11,89 11,90-12,39 12,40 & un <br /> HSM ,34 ,33 .31 ,30 ,29 ,28 <br />PTHP COP 2,50-2.69 2,70-2,89 2.90-3,09 3,10-3,29 3,30-3,49 3,50-3,69 3,70-3.89 3.90-4,19 <br /> HSM ,38 .37 ,34 ,32 ,30 ,29 ,27 ,26 <br />Electric Strio 1.0 <br />Gas & Other Fuels 1,0 ISee Table 6A-18 for Credit Multinlierl <br />MINIMUMS: CENTRAL UNITS-AIR SOURCE SPLIT SYSTEM 6,8 HSPF, SINGLE PKG, 6,6 HSPF, WATER SOURCE 3,8 COP, GROUND WATER SOURCE 3,4 COP, PTHP 2,5-2,7 COP, <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2,1 OF APPENDIX C, 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3,1 OF APPENDIX C, 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION, <br /> <br />-5- <br />