<br />WINTER POINT MULTIPLIERS (WPM) <br /> <br />~ <br />I <br /> <br />CLIMATE ZONES - 4 5' 6 - <br /> <br />6A-10 WINTER OVERHANG FACTORS (WOFI .- <br /> r OH RATIO ,00-,11 2-,1,\ ,18',26 .27-,35 ,36..46 .47'.57 .58- .70 .71-,83 I ,84-1.18 1.19-1.72 11.73-2.73 2.74+ <br /> , SINGLE PANE GLASS <br /> N 1,00 1.03 1,05 1.08 1.10 1.13 1.15 1,18 1.20 1.24 1.29 1,34 <br /> NE/NW 1.00 1.07 1.10 1.15 1.20 1.25 1.30 1,35 1.39 1.50 1.59 1.67 <br /> EIW 1.00 .71 J .57 .19 -.20 -,65 -1.05 -1.48 -2.03 -3.01 -4,06 -5,04 <br />>1 SE/SW 1,00 .93/ .90 .80 .68 ,54 .39 .22 .05 -,33 -.71 -1,01 <br />lD <br />l- S 1,00 .9~ ,92 ,83 .70 .54 ,36 .13 -.13 -.70 -.98 -1,09 <br />ua:: V DOUBLE PANE GLASS <br />wo <br />iLl I N 1.00 1.05 1.07 1,11 1.14 1.18 1.21 1.24 1.28 1.34 1,40 1.47 <br />en , <br /> ! NE/NW 1.00 1,11 1.16 1.24 1.32 1.41 1.48 1.56 1.63 1.80 1.94 2.08 <br /> i E/W 1,00 .88 .82 ,66 .50 ,31 .15 -.03 -.26 -,66 -1.10 -1.50 <br /> I SE/SW 1,00 ,95 ,92 .85 .76 ,65 .54 .41 .28 -.01 -.30 -,52 <br /> I S 1.00 ,96 .94 ,87 .78 .65 .51 ,33 .13 -.30 -,51 -.60 <br /> ~ OH LENGTH' Oft. 1 ft. 1'12 ft, 2ft, 3 ft. 3'12 ft. 4'1,ft, 5'/, ft. 6% ft. 9'12ft, 14ft, 20ft,+ <br /> 'TO SELECT BY OVERHANG LENGTH, NO PART OF GLASS SHALL BE MORE Ttj,AN 8 FT. BELOW THE OVERHANG. <br /> <br />..., <br /> <br />6A-11 WALL WINTER POINT MULTIPLIERS /WPM) <br /> FRAME CONCRETE BLOCK' FACE BRICK LOG <br /> j INT. INSULATION ~XT. INSUL R-VALUE WOOD FR <br /> WOOD STEEL NORMAL WT. NOR. WT. 0-6,9 7.0 6 INCH <br />R.V ALUE EXT ADJ EXT ADJ R-VALUE EXT ADJ EXT 7-10,9 2.1 R.V ALUE EXT <br />0-6.9 6,8 5,3 9.4 6.7 0-2,9 6.0 3,1 6,0 11-18,9 1.7 0-2.9 2.2 <br />7.10.9 2.5 2.1 4.4 3.3 3-4.9 3,8 2.3 2.8 19-25.9 1,0 3-6.9 1,2 <br />11-12.9 ,2.lt- ;0" I "1.lf ' 3,3 2.6 5-6,9 2.9 1.9 2,0 26 & Uo ,6 7 &Uo .9 <br />13-18,9 ....1.8 "'-r:s 3.0 2,4 7-10.9 2.3 1,5 1,5 R-V ALUE BLOCK 8 INCH <br />19-25.9 1,1 1,0 2.6 2.2 11-18,9 1.5 1.1 .8 0-2.9 3,7 R.VALUE EXT <br />26& Uo .7 ,7 1,4 1.2 19-25.9 .8 .7 3.6.9 2.6 0-2.9 1.2 <br /> 26 & Uo .5 .5 7-9.9 1,8 3-6.9 .9 <br /> 10& Un 1.3 7 Ro Iln .7 <br /> <br />6A-12 DOOR WINTER POINT MULTIPLIERS WPMI <br />DOOR TYPE EXTERIOR ADJAr,ENT <br /> <br /> 6A-13 CEILING WINTER POINT MULTIPLIERS /WPM) <br /> UNDER ATTI~ SINGLE ASSEMBLY CONCRETE DECK ROOF <br /> R-VALUE WPM R-VALUE WPM CEILING TYPE --- <br /> 19-21.9 1.(1- 10-10.9 1.8 R-V ALUE DROPPED EXPOSED <br /> 22.25.9 q-g~ } 11-12.9 1.6 10-13,9 1,2 1.3 <br /> 26-29.9 -r 13-18.9 1.5 14-20.9 .7 .7 <br /> 30-37,9 .6 19-25,9 1.1 21 & Up .4 .3 <br /> 38 & Uo .4 26-29,9 ,6 <br /> ~n}l, IJn d <br />6A-14 FLOOR WINTER POINT MULTIPLIERS /WPM) <br />SLAB-ON-GRADE RAISED RAISED WOO[)2 <br />EDGE INSULATION CONCRETE POST OR PIJ:R STEM WALL wi UNDER ADJACENT <br /> CONSTRUCTION FLOOR INSULATION <br />R-V ALUE ~ R.VALUE WPM R-VALUE WPM WPM WPM <br />0-2.9 ( 2,5 .J 0-2,9 4.0 0-6.9 7.9 1.8 5,3 <br />3-4.9 l':7 3-4.9 1,8 7-10.9 2,1 .7 2.1 <br />5-6.9 -2,4 5-6.9 1,1 11-18.9 1,5 .5 1,8 <br />7 Ro IIn -2.7 7 Rolin _8 HI}l, Iln !l 3 10 <br /> <br />WOOD <br /> <br />INSULATED <br /> <br />6A.15 INFILTRATION WINTER POINT MULTIPLIERS (WPM) <br />," INFILTRATION PRACTICE WPM <br />SEE TABLE 6A-21 <br />PRACTICE #1 <br />PRACTICE #2 <br /> <br />6A-16 DUCT MULTIPLIERS OM <br /> <br /> <br />SUPPLY DUCTS IN <br />UNCONDITIONED SPACE <br /> <br /> <br />RETURN DUCTS <br />IN UNCONDITIONED SPACE <br />1,14 <br />.10 <br /> <br />RETURN DUCTS <br />IN CONDITIONED SPACE <br />1,10 <br />1.07 <br />1.06 <br />1.00 <br />1,00 <br /> <br />SUPPLY DUCTS IN <br />CONDITIONED SPACE' <br /> <br />6A-17 HEATING SYSTEM MULTIPLIERS /HSMI <br />_SYST~M_TY~_ HEATING SYSTE_M MULTIPLIERS IHSM -..- <br />Central Heat --.-.!:i~PL __ "- __6.40-6.79 6.80-6.89 6.90-7,39 __ -. 7~ _~Q-8.~L ----.MO-8.89 8.9-9,39 9,4-9,89 -- <br />Pump Units HSM .53 .50 ~49 { .46 ) .4~ .41 .38 .36 <br /> HSPF 9.90-10.39 10.40-10.89 10.90.11,39 11~" 11.90-12.39 12.40 & up <br /> HSM ,34 .33 .31 ,30 .29 ,28 <br />PTHP COP 2,50-2.69 2.70-2.89 2.90-3.09 3.10-3.29 3.30.3,49 3.50-3.69 3.70-3.89 3.90-4,19 <br /> HSM ,40 .37 .34 .32 .30 .29 .27 .26 -- <br />Electric Strip 1.0 <br />Gas & LP Gas 1.0 /Se~Table 6A-18 for Credit Multiplier) <br /> MINIMUMS: CENTRAL UNITS-AIR SOURCE SPLIT SYSTEM 6.8 HSPF, SINGLE PKG. 6.6 HSPF, WATER SOURCE 3.8 COP, GROUND WATER SOURCE 3.4 COP, PTHP SEE TABLES 6-6 TO 6-8. -- <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION. <br /> <br />-5- <br /> <br /> <br />Ai. <br />