Laserfiche WebLink
<br />A9nlTIONAL TABLES <br /> <br />6""18 HEA:rING CREDIT MULTIPLIERS HCM <br />SYSTEM TYPE <br />Attic Radiant Barrier <br />Multizone <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />Natural Gas <br /> <br />HCM <br />HCM <br />------~.~ <br />AFl,JI;_~_ . <br />HCM <br />HCM <br /> <br />_~____u . _ _ . Jt~AJ,!~~~R~[)ltMULTI~~~.B!{HC~_____~_ <br />,98 <br />._--_._~----- .--.---------- <br />.95 <br /> <br />LP Gas <br /> <br />---------,.-._- ~_.__..- ----.....-- <br />.68-.72 .73-.77 .78-.82 .83-.87 _~-,9g__ .~&Up <br />---- - ~-- <br />.61 ,56 .53 ,50 ,47 .44 <br />.77 ,72 .67 ,63 ,60 .57 <br /> <br />6A-19 COOLING CREDIT MULTIPLIERS CCM <br />SYSTEM TYPE COOLING CREDIT MULTIPLIERS CCM <br />Ceilin Fans ___~. .86. <br />Cross Ventilation n ____~___...Jl!5.______~__m <br />Whole House Fan .95. <br />Muilizone ,95 <br />Attic Radi nt Barri r ,9 <br /> <br />.Credit may be taken for only <br />one of these system types concurrently. <br /> <br />SYSTEM TYPE <br /> <br /> <br />Heat Recovery Unit <br /> <br />Wi h .... .. Air n i i n ~OT WATER C~EDIT rL TIPUERS (HWC.M}Heat Pump <br /> <br /> <br />~~ ~1'~9 2~j_~~9,gE;;9r~o~r <br /> <br /> <br />A HWM MUST BE USED IN CONJUNCTION WITH ALL HWCM. SEE TABLE 6A-9. EF MEANS ENERGY FACTOR. <br /> <br />Dedicated Heat Pump <br /> <br />Solar <br /> <br />6A-21 INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST (SEE SECTION 606) <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE #1 606,1 COMPLY WITH ALL INFILTRATION PRESCRIPTIVES. <br />Windows Maximum of 0.34 CFM oer linear foot of operable sash crack (includes sliding glass doors). <br />Exterior & Adiacent Doors Maximum of 0.5 CFM per sq. ft. of door area' solid core, wood panel, insulated or glass doors onlv. <br />Exterior Joints & Cracks To be caulked, aasketed. weatherstripped or otherwise sealed. <br />PRACTICE #2 606.1 COMPLY WITH #1 AND THE FOLLOWING: <br />Exterior Walls and Floors Top plate penetrations sealed. Infiltration barrier installed. Sole plate/floor joint caulked or sealed. .. <br />Exterior Walls & Ceilings Penetrations ioints and cracks on interior surface caulked, sealed or oasketed. <br />Ductwork Ductwork in unconditioned space must be sealed. <br />Fireplaces Equipped with outside combustion air, doors and flue dampers. <br />Exhaust Fans Equipped with dampers. Combustion devices see 606.1 .A.2 <br />PRACTICE #3 606.1 COMPLY WITH PRACTICES #1 AND #2 AND THE FOllOWING: <br />Ceilinos Infiltration barrier installed. <br />Interior Walls Too oenetrations sealed or ioints & cracks on interior walls caulked sealed or qasketed. <br />Recessed Liohts Sealed from conditioned & insulated from ventilated a:~ic spaces. <br />Ductwork All ductwork located in conditioned space. <br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust <br /> by-products to outside. Combustion cooking appliances see section 606.1.A.3 <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612,1 Comply with efficiency requirements in Table 6-11. Switch or clearly marked circuit breaker (electricl <br />., or cutoff (oas) must be orovided. External or built-in heat trao reauired. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated), Non-commercial pools must have <br /> a pump timer. Gas spa & pool heaters must have a minimum thermal effiCiency of 78%. <br />Shower Heads 612.1 Water flow must be restricted to no more than 3 gallons per minute at 80 PSIG. <br />Air Distribution System 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br /> sealed, insulated, and installed in accordance with the criteria of Section 61 O. Ducts in unconditioned <br /> attics must be insulated to a minimum of R-6, Air handlers shall not be installed in attics unless in <br /> mechanical closet. <br />HV AC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. <br />Insulation 604,1, 602,1 CeilinQs-Min. R-19. Common walls-Frame R-l1 orCBS R-3 both sides. Common ceilinQ & floors R-ll. <br /> <br />-6- <br />