Laserfiche WebLink
<br />. WINTER POINT MULTIPLIERS (WPM) <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A-10 WINTER OVERHANG FACTORS (WOF) <br />J OH RATIO ,00-,11 I ,12-.17 I ,18-,26 I ,27-,35 / ,36-,46 I .47-,57 I .58-.70 I ,71-,83 I ,84-1,18 /1.19-1.72/1.73-2,73 2,74+ <br /> SINGLE PANE GLASS <br />N 1.00 1.03 1.05 1.08 1.10 1,13 1,15 1.18 1.20 1.24 1.29 1.34 <br />NE/NW 1.00 1.07 1,10 1,15 1.20 1.25 1.30 1,35 1.39 1.50 1.59 1.67 <br />ENV 1.00 ,71 ,57 .19 -,20 -.65 -1.05 -1.48 -2.03 -3,01 -4,06 -5,04 <br />SE/SW 1.00 ,93 .90 ,80 ,68 ,54 .39 ,22 .05 -.33 -,71 -1,01 <br />.... S 1.00 .95 .92 .83 ,70 ,54 ,36 ,13 -.13 -.70 -.98 -1.09 <br />(.)a: DOUBLE PANE GLASS <br />~[ N 1.00 1.05 1.07 1.11 1.14 1.18 1.21 1.24 1.28 1,34 1.40 1.47 <br />NE/NW 1.00 1.11 1.16 1,24 1.32 1.41 1.48 1.56 1.63 1.80 1.94 2,08 <br />ENV 1.00 ,88 ,82 ,66 .50 ,31 ,15 -.03 -.26 -,66 -1,10 -1.50 <br />SE/SW 1.00 .95 ,92 .85 ,76 .65 ,54 .41 ,28 -.01 -.30 -,52 <br />S 1.00 ,96 .94 .B7 ,7B ,65 .51 ,33 ,13 -.30 -,51 -,60 <br />OH LENGTH' Oft, 1 ft. 1'h ft. 2 ft, 3ft. 3'hft. 4Y2ft. 5'h ft. 6'h ft, 9Y2ft. 14ft, 20ft,+ <br /> 'TO SELECT BY OVERHANG LENGTH, NO PART OF GLASS SHALL BE MORE THAN 8 FT. BELOW THE OVERHANG. <br /> <br />6A-l1 WALL WINTER POINT MULTIPLIERS WPM <br />FRAME <br /> <br />" <br /> <br />R-V ALUE <br />0-6,9 <br />7-10.9 <br />11-12.9 <br />13-1B,9 <br />19-25.9 <br />26& U <br /> <br />WOOD <br />EXT ADJ <br />6.B 5.3 <br />2.5 2.1 <br />2,0 l,B <br />1.B 1.6 <br />1.1 1. 0 <br />.7 .7 <br /> <br />STEEL <br />EXT ADJ <br />9,4 6,7 <br />4.4 3.3 <br />3,3 2,6 <br />3,0 2.4 <br />2.6 2.2 <br />1.4 1.2 <br /> <br /> <br />CONCRETE BLOCK' <br />INT. INSULATION <br />NORMAL WT. <br />EXT ADJ <br />6,0 3,1 <br />3.B 2,3 <br />2,9 1.9 <br />2.3 1.5 <br />1.5 1.1 <br />,8 .7 <br />,5 .5 <br /> <br /> <br />6A-12 DOOR WINTER POINT MULTIPLIERS 6A-13 CEILING WINTER POINT MULTIPLIERS (WPMI <br />DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOFING <br /> R-VALUE WPM R-VALUE WPM CEILING TYPE <br />WOOD 7.6 5.9 19-219 1.0 10-10,9 1.8 R-V ALUE DROPPED EXPOSED <br /> 22-25,9 ,9 11-12.9 1.6 10-13.9 1.2 1.3 <br />INSULATED 5,1 4,0 26-29.9 .7 13-1B,9 1.5 14-20,9 .7 .7 <br /> 30-37,9 .6 19-25,9 1.1 21 & Uo .4 .3 <br /> 3B & Uo .4 26-29.9 .6 <br /> 10 ~ Iln 4 <br />6A-14 FLOOR WINTER POINT MULTIPLIERS (WPMl <br />SLAB-QN-GRADE RAISED RAISED WOO[)2 <br />EDGE INSULATION CONCRETE POST OR PIER STEM WALL wI UNDER ADJACENT <br /> CONSTRUCTION FLOOR INSULATION <br />R-VALUE WPM R-VALUE WPM R-VALUE WPM WPM WPM <br />0-2.9 2,5 hi 0-2.9 4.0 0-6,9 7,9 N/A 5,3 <br />3-4.9 -1.7 3-4,9 l.B 7-10,9 2.1 .7 2.1 <br />5-6.9 -2.4 5-6,9 1.1 11-1B,9 1.5 ,5 1.B <br />7 ~ tIn -'7 7 ~ tIn II 1q ~ Iln q 1 10 <br /> <br />WPM) <br /> <br />6A-15 INFILTRATION WINTER POINT MULTIPLIERS (WPM) 6A-16 DUCT MULTIPLIERS OM <br /> <br />INFILTRATION PRACTICE WPM <br />(SEE TABLE 9PI <br />PRACTICE #1 6.2 <br />PRACTICE #2 4.1 <br /> " <br /> <br />SUPPLY DUCTS IN <br />UNCONDITIONED SPACE <br /> <br /> <br />RETURN DUCTS <br />IN UNCONDITIONED SPACE <br />1.14 <br />1.10 <br />1.09 <br />1.10 <br />1.07 <br /> <br />RETURN DUCTS <br />IN CONDITIONED SPACE <br />1.10 <br />1.07 <br />1.06 <br />1.00 <br />1.00 <br /> <br />SUPPLY DUCTS IN <br />ONDITIONED SPACE' <br /> <br />6A-17 HEATING SYSTEM MULTIPLIERS (HSMI <br />SYSTEM TYPE HEATING SYSTEM MULTIPLIERS lHSMl <br />Central Heat HSPF 6,40-6,79 6,BO-6,B9 6,90-7,39 7.40-7.B9 7,90-B.39 B.40-B,B9 8.9-9.39 9.4-9.89 <br />Pump Units HSM .53 .50 .49 ,46 .43 .41 ,38 .36 <br /> HSPF 9.90-10,39 10.40-10,89 10.90-11.39 11.40-11.89 11.90-12.39 12,40 & uo <br /> HSM ,34 ,33 .31 ,30 ,29 .28 <br />PTHP COP 2,50-2,69 2,70-2,89 2,90-3,09 3,10-3,29 3,30-3,49 3.50-3,69 3,70-3.89 3.90-4.19 <br /> HSM .38 .37 .34 ,32 .30 .29 .27 .26 <br />Electric Strio 1.0 <br />Gas & Other Fuels 1.0 (See Table 6A-18 for Credit Multiolierl <br />MINIMUMS: CENTRAL UNITS-AIR SOURCE SPLIT SYSTEM 6.8 HSPF, SINGLE PKG. 6.6 HSPF, WATER SOURCE 3.8 COP, GROUND WATER SOURCE 3.4 COP, PTHP 2.5-2.7 COP. <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION. <br /> <br />-5- <br />