<br />SUMMER POINT MULTIPLIERS (SPM) <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />.6A-1 SUMMER OVERHANG FACTORS ISOFl FOR SINGLE AND DOUBLE PANE GLASS. <br />~r OH RATIO ,00-,11 .12-,17 .18-,26 ,27-,35 ,36-.46 .47-.57 ,58-.70 .71-.83 ,84-1.18 1.19-1,72 1.73-2.73 2,74+ <br />N 1.00 ,94 ,91 .87 .83 .79 .76 ,72 ,69 ,63 .56 .50 <br />NElNW 1.00 ,94 ,91 ,85 ,79 ,72 ,68 ,63 .58 ,50 .40 .36 <br />I-a: E/W 1,00 .95 .92 ,85 ,78 ,70 ,64 ,58 ,52 .42 <br />frlo ,33 .26 <br />ml SElSW 1.00 ,93 ,90 .81 .72 .62 .55 .49 .42 ,33 ,27 ,22 <br />S 1.00 .91 ,87 ,77 ,67 ,57 .50 .45 .39 .32 .28 .25 <br />ru:IT J:1\lr::TI-l* Oft 1 ft, 1% ft ?ft ~ft ~'j, ft. 4'j, ft. "if, ft 6% ft. Qi/,ft 14ft ?Oft+ <br /> 'T 0 select bv Overhana Lennth no nart of alass shall be more than 8 ft. below the overhano. <br /> <br />6A-2 WALL SUMMER POINT MULTIPLIERS SPM <br /> <br />FRAME <br /> <br />WOOD <br />EXT ADJ <br />6.4 2.2 <br />2.3 .8 <br />1.9 ,7 <br />1.7 .6 <br />1.0 ,3 <br />,6 ,2 <br /> <br />R-V ALUE <br />0-6.9 <br />7-10.9 <br />11-12.9 <br />13-18,9 <br />19-25.9 <br />26& U <br /> <br />STEEL <br />EXT ADJ <br />8.9 2,9 <br />4.1 1.3 <br />3.0 1.0 <br />2.8 0,9 <br />2.4 0.8 <br />1,3 0.4 <br /> <br /> <br />CONCRETE BLOCK' <br />INT. INSULATION EXT.INSUL <br />NORMAL WT. NOR. WT. <br />EXT ADJ EXT <br />2,5 .9 2.5 <br />1.4 .7 .7 <br />1.0 .6 .3 <br />,8 .4 .1 <br />.4 .3 0 <br />.2 .2 <br />.1 .1 <br /> <br /> <br />6A-3 DOOR SUMMER POINT MULTIPLIERS 6A-4 CEILING SUMMER POINT MULTIPLIERS ISPMl <br />DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOFING <br /> R-V ALUE SPM R-VALUE SPM CEILING TYPE <br />WOOD 7.2 2.4 19-219 1.1 10-10.9 3,0 R-V ALUE DROPPED EXPOSED <br /> 22-25,9 .9 11-12.9 2.7 10-13,9 3.0 3,3 <br />INSULATED 4,8 1.6 26-29.9 .7 13-18,9 2.4 14-20.9 2.0 2.1 <br /> 30-37.9 .6 19-25.9 1.8 21 & Uo 1.4 1.3 <br /> 38 & Uo .4 26-29,9 1.1 <br /> ~o R. Iln 00 <br />6A-5 FLOOR SUMMER POINT MULTIPLIERS ISPMl <br />SLAB-ON-GRADE RAISED RAISED WOO02 <br />EDGE INSULATION CONCRETE POST OR PIER STEM WALL wi UNDER ADJACENT <br /> CONSTRUCTION FLOOR INSULATION <br />R-V ALUE SPM R-V ALUE SPM R-V ALUE SPM SPM SPM <br />0-2.9 -31,9 0-2.9 -1.0 0-6,9 0.9 N/A 5.3 <br />3-4,9 -31.8 3-4,9 -1.7 7-10.9 -1.1 -2.8 2,1 <br />5-6,9 -31.7 5-6.9 -1.7 11-18.9 -1,0 -2,2 1.8 <br />7 R.lln -:11 R 7 R. Iln -17 10 R.lln -00 _1 R {.o <br /> <br />SPM) <br /> <br /> <br />6A-7 DUCT MULTIPLIERS OM <br /> <br />SUPPLY DUCTS IN <br />ONDITIONED SPACE' <br /> <br /> <br />RETURN DUCTS <br />IN UNCONDITIONED SPACE <br />1,14 <br />1.10 <br />1.09 <br />1.10 <br />1.07 <br /> <br />RETURN DUCTS <br />IN CONDITIONED SPACE <br />1,10 <br />1.07 <br />1.06 <br />1.00 <br />1,00 <br />1. <br /> <br />13.8 <br />10.9 <br />7, <br /> <br />SUPPLY DUCTSIN <br />UNCONDITIONED SPACE <br /> <br />6A-B COOLING SYSTEM MULTIPLIERS ICSMl <br />SYSTEM TYPE COOLING SYSTEM MULTIPLIERS ICSMl <br />Ceotral Units (SEER) Ratina 7.5-7.9 8.0-8.4 8,5-8,8 8.9-9.4 9.5-9,9 10.0-10.4 10.5-10,9 11.0-11.4 11,5-11.9 12.0-12.4 <br />CSM .45 .43 .40 .38 ,36 .34 .32 .31 .30 ,28 <br />PTAC & Room Units (EER) Ratina 12.5-12.9 13.0-13.4 13.5-13.9 14.0-14.4 14.5-14.9 15.0-15.4 15,5-15.9 16,0-16.4 16.5-16.9 17,0-17.4 17.5& Uo <br />CSM ,27 ,26 ,25 .24 .24 .23 .22 .21 .21 ,20 .19 <br />MINIMUMS: CENTRAL UNITS-AIR COOLED SPLIT SYSTEM 10.0 SEER. SINGLE PKG. 9.7 SEER. GROUND WATER COOLED 11.0 EER. PTAC-SEE TABLE 6-3. <br /> <br />6A-9 HOT WATER MULTIPLIERS IHWMl <br />SYSTEM TYPE HOT WATER MULTIPLIERS IHWM <br />Elec1ric Resistance EF ,80-.81 ,82-.83 ,84-,85 ,86-.87 ,88-.90 .91-.93 .94-,96 .97 & Up <br />HWM 4183 4081 3984 3891 3803 3678 3560 3450 <br />Natural Gas EF .43-.47 ,48-.49 I .50,51 .52-.53 ,54-.55 ,56-.57 ,58- .59 .60-.61 .62-,63 .64-.65 .66 & Uo <br />HWM 3098 2775 I 2664 2562 2467 2379 2297 2220 2138 2081 2018 <br />to Gas HWM 4195 3758 I 3608 3469 3340 3221 3110 3007 2910 2819 2733 <br />Solar EF 1,0-1.9 2,0-2.9 3,0-3.9 4.0-4.9 5.0 & UO <br />HWM R4 42 ?R ?1 1" <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION. <br /> <br />-3- <br />