Laserfiche WebLink
<br />s. Horizontal joint reinforcing is to be used at 16" o.c. <br />with prefabricated tees and corners to be used at the <br />appropriate conditions. (continuous thru pilaster and <br />filled cells with a 8" lap) <br />t. High lift grouting techniques are tc? employed as required <br />by the code. The grout components shall not be allowed to <br />segregate when placed. <br />