Laserfiche WebLink
<br />'""" . r \ , i ....J.'_ I ("~ ~ <br />_ X' \-\'-1""': ,,'..J:'::)C .- ... . ~"- . <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />FORM 600A-93 . Residential Component Prescriptive Method A CENTRAL <br />PRO~ECT NAME: ATTACHED PATIO HOME :BUILDER: GENERAL HOME DEVELOPMENT CORP. <br />AND ADDF~: . J. COTTONWOOD PLA: PERMITT~ING J : CLIMATE ~ <br />,j'~lf'( Cc-ll.:')t.t.ft""'ZEPHYRHILLS, FL 335: OFFICE: : ZONE: 4: _: 5: _: 6:_: <br />mmER: \s~,"ero..\ -t~I't"-eh.\f\:.l'''1.~(Y,e,,--r : PERMIT O. '/R~"'" tE : JURISDICTION NO. 6/1 b vi) <br />- 0v r-f, CK <br />1. New construction or addition 1. New Construction <br />2. Single family detached or Multifamily attached 2. Multi-F~mily <br />3. If Multifamily-No. of units 3. 4 <br />4. If Multifamily, is this a worst case (yes/no) 4. No <br />5. Conditioned floor area (sq.ft.) 5. 1195.00 <br />S. Predominant eave overhang (ft.) 6. 2.30 <br />7. Porch overhang length (ft.) 7. 0.00 <br />3. Glass area and type: Single Pane <br />B. Clear Glass 8a.239.4sqft <br />b. Tint, film or solar screen 8b. O.Osqft <br />~. Floor type and insulation: <br />a. Slab on grade (R-value, perimeter) <br />LO.Net Wall type area and insulation: <br />a. Exterior: 1. Concrete (Insulation R-value) 10a--1 R= 4.20, 285.50sqft_ <br />a. Exterior: 2. Wood frame (Insulation R-value) 10a-2 R=11.00, 40.30sqft____ <br />.1.Ceiling type area and insulation: <br />a. Under attic (Insulation R-value) <br />a. Under attic (Insulation R-value) <br />2.Air distribution systems <br />a. Ducts (Insulation + Location) <br />3.Cooling system <br /> <br />Department of Community Affairs <br /> <br />SN: 60,96 <br /> <br />Double Pane <br />O.OOsqft <br />O.OOsqft <br /> <br />9a.R= 0.00 , <br /> <br />60.80 ft <br /> <br />11a.R=22.00, 98.00sqft_ <br />11a .R=30 .00 , 1200.00sqft__ <br /> <br />4.Heating System: <br /> <br />12a. R= 6.00, uncond <br />13. Type: Central A/C <br />EER: 10 .00 <br />14. Type: Heat Pump <br />HSPF: 7.00 <br />15. Type: Electric <br />EF: 0.90 <br /> <br />5.Hot water system: <br /> <br />6.Hot Water Credits: (HR-Heat Recovery, <br />DHP-Dedicated Heat Pump) <br />7.Infiltration practice: 1, 2 or 3 <br />8.HVAC Credits (CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, RB-Attic radiant <br />barrier, MZ-Multizone) <br />9.EPI (must not exceed 100 points) <br />a. Total As_Built points <br />b. Total Base points <br /> <br />16. <br /> <br />17. <br />18. <br /> <br />2 <br /> <br />19. <br />19a. <br />19b. <br /> <br />83.39 <br />19255.47 <br />23089.58 <br /> <br />------------------------------------------------------------------------------- <br /> <br />------------------------------------------------------------------------------ <br /> <br />Hereby certify that the plans and <br />~ecifications covered by this calcu- <br />~tion are in compliance with the <br />lorida Energy Code. <br /> <br />, <br /> <br />Review of the plans and specifications <br />covered by this calculation indicates <br />compliance with the Florida Energy <br />Code. Before construction is completed <br />this building will be inspected for <br />compliance in accordance with Section <br />553.908 F.S. <br /> <br /><EPARED BY: <br />~TE : <br /> <br />" ~ . \-D~ <br />. . 1~ '. \. A A- <br />~-,-9') <br /> <br />hereby certify that this building is <br />) compliance with the Florida Energy <br />>de. <br /> <br />INER/AGENT: <br />ITE: <br /> <br />l'~ <br />" . ", <br />';' 1+-J... <br />. ~- rr -'45 <br /> <br />BUILDING OFFI~L'4r~...11- <br />DATE: _3.. -;:1.. ?- <br />